PowerFLO
™
Pressure Sensing Demand Switch
The PowerFLO Series 7800 pump is controlled by a built-in
pressure sensing demand switch. When a faucet or valve
is opened down stream of the pump, line pressure drops
thus starting the pump automatically. Conversely, when the
valve shuts, the line pressure increases turning the pump off
automatically. The pressure switch actuates in response to the
pump outlet pressure at a predetermined and preset pressure.
The pump label indicates the predetermined ON and OFF
Demand
pressures. Typically, the OFF pressure is accurately set at the
Factory and the ON pressure is within an allowable range below
4.07
103.4
that value. In response to the characteristics of the system
3.77
in which the pump is installed, the flexibility and length of the
95.8
tubing, the faucet or valves and the duration that they are open;
2.13
these pressure settings may vary. Therefore, variation in pressure
2.13
54.1
54.1
3.67
setting is expected with use and over time.
93.2
1.83
46.6
3.00
76.2
8.84
224.5
2.25
7.58
57.2
192.5
3.17
80.5
4.00
101.6
Toll Free: 1-866-DELAVAN (335-2826) • Toll Free Fax: 1-888-726-5906 • delavanagpumps.com
7800 Series
Standard Warranty
Delavan warrants PowerFLO Series Pumps for a period of two
years from date of manufacture.
All products sold by Delavan are warranted only to purchasers
from Delavan for resale or for use in purchasers' own business
or original equipment manufacture, against defects in
workmanship or materials under normal use, maintenance and
service (rental use excluded).
The sole and exclusive obligation of Delavan under this or any
implied warranty shall be to replace or, at its option, to repair,
without charge, any product which is determined by Delavan
to be defective in workmanship or materials after the product is
returned to the Delavan factory*, shipping costs prepaid.
In no event shall Delavan be liable to any person for indirect
or consequential damages or for injury or commercial loss
resulting from any use or inability to use any Delavan product.
Delavan expressly negates any other warranty, express or
implied, including any warranty of merchantability or fitness for
a particular purpose, or arising from any course of dealing or
custom or usage of trade.
No person, including any dealer or representative of Delavan,
is authorized to make any representation or warranty on behalf
of Delavan in addition to or inconsistent with these provisions.
Purchasers to whom these provisions apply agree to hold
Delavan harmless from claims by their customers in excess of
the obligations of Delavan expressly set forth herein
* Important return safety instructions:
When you return your pump for warranty or repair, you must
always do the following:
1. Flush chemical residue from the pump
(best done in the field).
2. Tag pump with type of chemicals having been sprayed
3. Include complete description of operation problem, such as
how pump was used, symptoms of malfunction, etc.
Since pumps can contain residues of toxic chemicals these
steps are necessary to protect all the people who handle return
shipments, and to help pinpoint the reason for the breakdown.
www.delavanagpumps.com
Installation
•
Operation
•
Repair
PowerFLO
7800 Series
™
12 Volt DC Motor-Driven Diaphragm Pumps
Heat Rise
200
Motor
180
Type: 12 VDC, permanent magnet, totally enclosed,
160
non-ventilated
140
Leads: 16 AWG, 6" long
120
Duty Cycle: See Heat Rise graph
100
Temperature Limits: Motor is not equipped with thermal
80
protection. For user safety, optimal performance, and maximum
60
0
10
20
30
40
motor life, the motor surface temperature should not exceed
150°F (66°C) (See Heat Rise graphs).
Approximate values, actual values will vary with ambient temperature.
Pump
Quick Attach Nylon Inlet/Outlet Port Fittings
Type: 3 chamber positive displacement diaphragm pump, self
priming, capable of being run dry, demand or bypass model.
Item #
Description
3DFA38
5/8" QA x 3/8" HB Straight Fitting
Liquid Temperature: 140°F (60°C) Max.
Priming Capabilities: 14 feet (4 m)
3DFA12
5/8" QA x 1/2" HB Straight Fitting
Max Pressure: 60 PSI
3DFE38
5/8" QA x 3/8" HB Elbow Fitting
Inlet/Outlet Ports:
7801/7802/7822: Quick Attach (See chart on right)
3DFE12
7811/7812:
3/8" FNPT
5/8" QA x 1/2" HB Elbow Fitting
3DFF38
5/8" QA x 3/8" FNPT Straight Fitting
Materials of Construction
Housing: Polypropylene
Diaphragm: Santoprene
3DFF12
5/8" QA x 1/2" FNPT Straight Fitting
Valves: Viton
Fasteners: Stainless steel
Weight
6 lbs (2.7 kg)
Toll Free: 1-866-DELAVAN (335-2826) • Toll Free Fax: 1-888-726-5906 • delavanagpumps.com
•
Parts
Recommended
Shell Temperature
Limit
6.19 Amps
50
60
70
80
90
100
110
120
Time (Minutes)
w/ O-Ring, Nylon
w/ O-Ring, Nylon
w/ O-Ring, Nylon
w/ O-Ring, Nylon
w/O-Ring, Black Nylon
w/ O-Ring, Black Nylon
Need help?
Do you have a question about the PowerFLO 7800 Series and is the answer not in the manual?
Questions and answers
My pro flo is brand new and it dose not have the same pressure as my last one as it will only spray from 3 jets and will not activate the 4th on the same line
The Delavan 7800 Series pump may only be spraying from 3 jets and not activating the 4th jet due to one or more of the following possible causes:
1. Clogged Jet or Line: The 4th jet or its connecting tubing could be blocked by debris or chemical residue.
2. Uneven Pressure Distribution: If system pressure is too low or uneven, one jet may not receive enough pressure to operate. This could be caused by incorrect pressure switch adjustment or low voltage supply.
3. Air Lock or Leak: Air trapped in the line or a leak could prevent proper flow to the 4th jet.
4. Faulty Valve or Fitting: A damaged or improperly sealed valve or fitting may restrict flow to the 4th jet.
5. Pump Capacity Limit: If the flow demand exceeds the pump's rated capacity, it may not deliver enough flow to all jets simultaneously.
Check for clogs, ensure proper voltage (13.7V), inspect fittings, and verify that pressure switch settings are within factory specifications.