  • Page 1 Digital Thermometer TA410AX/BX Instruction Manual Thank you for purchasing the TA410AX/BX Digital Thermometer. Please read this instruction manual carefully before use so that you can use the product properly.
  • Page 2: Safety Precautions

    Safety Precautions Before operation, read this "Safety Precautions" section carefully to use the product properly. The precautions shown herein are divided into the two categories. Since both of them contain important safety precautions, make sure that you observe them. Improper handling poses the risk of death or serious injury. Warning Improper handling poses the risk of injury or damage to the product or Caution...
  • Page 3: Battery Installation

    1. Battery Installation * Turn off the unit when you replace the battery. (1) Use a coin to unscrew the battery cover. (2) Connect the battery cable to the battery and put it in the case. (3) Close the battery cover and firmly tighten the two screws. 2.
  • Page 4 3. Operating Procedures and Features (1) Power ON/OFF Press the POWER key. After all the digits have flashed on the display for one second, the unit is ready for measurement. Press the POWER key again to turn the unit off. Press the POWER key to turn off the unit at any point of time during operation.
  • Page 6: Error Messages

    4. Error Messages (1) Broken Detection Terminal Indication If the detection terminal of the probe gets broken or the probe is not connected, "Err" is indicated on the display as in the right figure. If so indicated, replace or connect the probe. (2) Over Range Indication If the temperature being measured goes beyond the measurable range, "or"...
  • Page 7: Maintenance

    5. How to Place the Probe Place the probe perpendicular to the contact surface or facing to the direction wind is coming from. In addition, note that the unit will not operate properly if the surface is rough or uneven. * Before measurement, check the measurable range of the probe.
  • Page 8 -MEMO-...
  • Page 9 -MEMO-...
  • Page 10 -MEMO-...
  • Page 11: Warranty

    Make sure to return this warranty together with the actual product. ICHINEN TASCO CO., LTD. 1-17-20 Inadauemachi, Higashi-Osaka City, Osaka 577-0002 JAPAN Phone: 81-6-6748-9310 Fax: 81-6-6748-9320 This warranty is exclusively for TA410AX/TA410BX. The accessories are not to be covered by this warranty. Authorized Dealer...