D - ASSEMBLY - INSTALLATION

3 - ADJUSTMENTS AND CONFIGURATIONS OF THE VARIABLE SPEED UNIT

R81
R53
R56
R94
J3
D-8
CAUTION :
DO NOT CHANGE R7
(FACTORY ADJUSTMENT)
Adjustment to obtain similar speed of the motor
whether in load or off load.
Adjustment to obtain motor stop with a 0V setpoint.
Adjustment to obtain the required speed with a 10V
setpoint.
Adjustment to obtain the maximum required intensity.
This adjustment is made after having connected an
ammeter in series with the motor and the motor being
locked.
Configuration according to the regulation mode, i.e.
with or without tacho generator.
WITH => « AVEC »
WITHOUT => « SANS »
8695 5832 / M
MOTOVAR MV20