Eagle CLGF30-NG Installation, Operating,  & Maintenance Instructions

Eagle CLGF30-NG Installation, Operating, & Maintenance Instructions

Advertisement

Quick Links

instruction
sheet
INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS
#383292
insPect contents iMMeDiAteLY AnD FiLe cLAiM With DeLiVerinG cArrier For AnY DAMAGe.
You Are resPonsiBLe For DAMAGe to Your unit iF returneD iMProPerLY PAcKeD.
Model: CLGF30-NG
Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or parts, this information is required.
CLGF30-NG
Model Number
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other
appliance.
MESURE DE SÉCURITÉ: Ne pas entreposer ni utiliser d'essence ni autres vapeurs ou liquides inflammables à proximité de cet
appareil ou de tout autre appareil.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
AVERTISSEMENT: L'installation, le réglage, la modification, la réparation ou l'entretien incorrects de cet appareil peuvent
causer des dommages matériels, des blessures ou la mort. Lire attentivement les instructions d'installation, de
fonctionnement et d'entretien avant de procéder à son installation ou entretien.
WARNING: Instructions must be posted in a prominent location. All safety precautions must be taken in the event the user
smells gas. Safety information can be obtained from your local gas supplier.
AVERTISSEMENT: Les instructions doivent être affichées dans un endroit très visible. Toutes les mesures de sécurité doivent
être prises au cas où l'utilisateur sente l'odeur de gaz. L'information de sécurité peut être obtenue de votre fournisseur local
de gaz.
CAUTION: These models are designed, built, and sold for commercial use only. If these models are positioned so the general
public can use the equipment, make sure that cautions, warnings, and operating instructions are clearly posted near each unit
so that anyone using the equipment will use it correctly and not injure themselves or harm the equipment.
ATTENTION: Ces modèles sont conçus, fabriqués, et vendus pour un usage commercial seulement. Si ces modèles sont placés
pour que le grand public puisse les utiliser, assurez-vous que les consignes d'attention, d'avertissement, et les instructions
d'utilisation soient clairement affichées près de chaque unité de sorte que n'importe quel utilisateur de l'appareil l'emploie
correctement et ne se blesse pas ou n'endommage pas l'appareil.
eagle Foodservice equipment, eagle Mhc, specFAB, and retail Display are divisions of eagle Group. ©2016 by the eagle Group
Gas Fryer (NG Unit)
CAUTION
SAVE YOUR BOX AND ALL PACKING MATERIALS.
IMPORTANT FOR FUTURE REFERENCE
Serial Number
• 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S. . • www.eaglegrp.com
• Phone: 302/653-3000 • (Foodservice) 800/441-8440 • (MHC/Retail) 800/637-5100
• Fax: 302/653-2065
Date Purchased
(continued on next page)
eG9937
revised 07/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLGF30-NG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eagle CLGF30-NG

  • Page 1 • 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S. . • www.eaglegrp.com • Phone: 302/653-3000 • (Foodservice) 800/441-8440 • (MHC/Retail) 800/637-5100 • Fax: 302/653-2065 eagle Foodservice equipment, eagle Mhc, specFAB, and retail Display are divisions of eagle Group. ©2016 by the eagle Group...
  • Page 2: Table Of Contents

    EAGLE GROUP. Congratulations on your purchase of this commercial cooking equipment. Eagle Group takes pride in the design and quality of our products. When used as intended and with proper care and maintenance, you will experience years of reliable operation from this equipment.
  • Page 3: Safety Precautions

    Gas Fryer (NG Unit) INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS LOCATION OF DATA PLATE The data plate is located on the side panel. IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery.
  • Page 4: General Installation Instructions

    There must be adequate clearance for removal of the front panel. All major parts except the burners are removable thru the front if the gas line is disconnected. & ! #!( ( !& !& < #*0H, # 1 , # 1 , CLGF30-NG ; (>0#9<,7 < A7B' ( 7 ' 6( >>> (continued on next page)
  • Page 5: Lighting Instructions

    Gas Fryer (NG Unit) INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS LIGHTIING INSTRUCTIONS Fryers are furnished with a Gas Control Safety Valve. Please follow the instructions below. Before Lighting Pilot and Burners Fill the fat tank about 3/4" below the full line with proper frying compound before lighting pilot. The reason for filling the tank 3/4"...
  • Page 6: Operating Instructions

    Gas Fryer (NG Unit) INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS < E: G CAUTION: The fryer must be turned completely off prior to draining the oil. Ensure the thermostat and gas control valve are in the off position and the pilot and burners are completely extinguished.
  • Page 7: Cleaning & Maintenance

    Gas Fryer (NG Unit) INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS CLEANING Initial Cleaning Always clean equipment thoroughly before first use. Clean the protective oil from the bright parts and interior of tank with an appropriate de-greasing solution. Daily Cleaning 1. Always turn unit off and allow it to cool completely before cleaning. 2.
  • Page 8 Gas Fryer (NG Unit) INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS MAINTENANCE OVERNIGHT SHUTDOWN Turn the temperature control knob to the off position. (The pilot flame alone will keep the frying compound temperature to 130-145°F(54.5-62.8 ). when not under any load. This will shorten preheat time when turned back on.) EXTENDED SHUTDOWN (4 DAYS OR LONGER) 1.
  • Page 9: Troubleshooting

    Gas Fryer (NG Unit) INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS && ' #$& TROUBLESHOOTING GUIDE " $' ! &* " ' < (continued on next page)
  • Page 10: Exploded View

    Gas Fryer (NG Unit) INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS EXPLODED VIEW MODEL: CLGF30-NG (optional) (continued on next page)
  • Page 11: Replacement Parts List

    Foodservice Equipment will be free from defects in materials and workmanship for a period of one year from date of original installation, not to exceed 18 months from date of shipment from the factory. Eagle Foodservice Equipment will replace, without charge, any defective parts or component material, upon demonstration to its satisfaction that a breach of warranty did not exist.
  • Page 12 • 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S. . • www.eaglegrp.com • Phone: 302/653-3000 • (Foodservice) 800/441-8440 • (MHC/Retail) 800/637-5100 • Fax: 302/653-2065 eagle Foodservice equipment, eagle Mhc, specFAB, and retail Display are divisions of eagle Group. ©2016 by the eagle Group...

Table of Contents