Download Print this page
ClimateMaster AHWG Installation, Operation & Maintenance Instructions Manual

ClimateMaster AHWG Installation, Operation & Maintenance Instructions Manual

Remote mount hot water generator module for tep series outdoor split unit

Advertisement

Quick Links

Model Nomenclature Example
Description and Installation Examples
Water Quality Requirements
Installation and Operating Instructions
Table of Contents
3
Wiring and Electrical Data
4
Wire Diagrams
5
Warranty
6-9
Revision History
AHWG Remote Mount
Generator Module
for TEP Series
Outdoor Split Unit
Installation, Operation &
Maintenance Instructions
Revised: March 12, 2019
Hot Water
97B0072N05
10
11-14
15
16

Advertisement

loading
Need help?

Need help?

Do you have a question about the AHWG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ClimateMaster AHWG

  • Page 1 AHWG Remote Mount Hot Water Generator Module for TEP Series Outdoor Split Unit Installation, Operation & Maintenance Instructions 97B0072N05 Revised: March 12, 2019 Table of Contents Model Nomenclature Example Wiring and Electrical Data Description and Installation Examples Wire Diagrams 11-14...
  • Page 2 This page was intentionally left blank.
  • Page 3 R e v i s e d : M a r c h 1 2 , 2 0 1 9 Model Nomenclature: for Remote Hot Water Generator AHWG 1 Accessory Future AHWG = Accessory Remote SS = Standard Hot Water Generator Size 1 = Standard Revision...
  • Page 4 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Hot Water Generator Module For Outdoor Compressor Section General Information potential cost of frequent maintenance may off set or exceed The HWG Module consists of an all-copper, vented double- any savings.
  • Page 5 20 mesh] size. The ClimateMaster Water Quality Table provides water quality requirements for ClimateMaster coaxial heat exchangers. The water should be evaluated by an independent testing facility comparing to this Table and when properties are outside of these requirements, an external secondary heat exchanger must be used to isolate the heat pump heat exchanger from the unsuitable water.
  • Page 6 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Hot Water Generator Module Refrigeration Installation For Outdoor Compressor Section Only Location/Mounting Wiring The HWG module should be mounted as close to the heat...
  • Page 7 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Hot Water Generator Module Refrigeration Installation Outdoor Compressor Section Only Figure 3a: Outdoor Compressor Section HWG Installation Table 1: HWG Refrigerant Line Sizing Line Set Size Capacity...
  • Page 8 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Hot Water Generator ANTI-SCALD Installation COLD WATER VALVE PIPING Anti-Scald The HWG is controlled by two sensors and the DXM2 micro- SUPPLY CONNECTIONS Valve Piping...
  • Page 9 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Hot Water Generator Module - Domestic Water Installation Warning! The HWG pump Is fully wired from the the refrigeration system and conserve the most energy.
  • Page 10 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Electrical - Wiring 208-230 Volt Operation HWG Module Wiring - For “Outdoor” Compressor Verify transformer tap with air handler wiring diagram to Section insure that the transformer tap is set to the correct voltage,...
  • Page 11 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Outdoor Split (TEP) DXM2 Wiring Diagram with Internal Flow Controller - 96B0005N65 Figure 6 CAUTION! WARNING!
  • Page 12 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Outdoor Split (TEP) DXM2 Wiring Diagram with Internal Flow Controller - 96B0005N65 G e o t h e r m a l H e a t P u m p S y s t e m s...
  • Page 13 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 115V Hot Water Generator Wiring Diagram - 96BN0141N11 Figure 7 c l i m a t e m a s t e r. c o m...
  • Page 14 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 230V Hot Water Generator Wiring Diagram - 96BN0141N12 Figure 8 G e o t h e r m a l H e a t P u m p S y s t e m s...
  • Page 15 R e m o t e H W G R e v i s e d : M a r c h 1 2 , 2 0 1 9 Warranty c l i m a t e m a s t e r. c o m...
  • Page 16 97B0072N05 ClimateMaster works continually to improve its products. As a result, the design and specifi cations of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specifi...