  • Page 1 MC PMRL Mobile Radio Router User Manual MC PMRL Version v1.0.0 MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 2: Table Of Contents

    REATE ..........................18 REATE NTERFACE 10 CONFIGURING VLAN ..........................19 10.1 VLAN ............................19 REATE 10.2 ..........................19 REATE NTERFACE MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 3 13.2 ..........................26 ROUBLESHOOTING 13.3 ..............................26 EPAIR 14 DISPOSAL ............................... 26 14.1 ........................ 26 ETURN OF THE OLD EQUIPMENT MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 4: General

    The operator must always observe the national regulations applicable in his country regarding the operation, functional testing, repair and maintenance of electronic devices. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 5: Qualification Of Personnel

    Separate the packaging components made of cardboard and paper as well as plastic and recycle them using the appropriate collection systems. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 6: Basic Safety Requirement

    The use of the open-source software by the customer in our product is not part of the profit we make with the contractual remuneration. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 7: Liability Regulations

    Alternatively, a list of the open source software used 4 Contents The package includes the accessories listed below. Please check that all accessories listed are included in your box. If a part is missing or damaged, please contact MC Technologies directly. ...
  • Page 8: Technical Specifications

    MC PMRL Mobile Radio Router 5 Technical specifications The following specifications apply to all versions of the MC PMRL. If these variants differ from one another, the different values are indicated separately. Technical Data Physical properties Physical characteristics Value Supply Voltage 10 V ...
  • Page 9: Ports And Display

    MC PMRL Mobile Radio Router 6 Ports and display The following figures show a maximum equipped version of the MC PMRL. Depending on the variant, your MC PMRL may not have all connections, display or control elements. Port Description Power supply...
  • Page 10: Installation

    Insert your SIM card as shown in the figure below until it locks into place. 7.3 Power supply The MC PMRL is operated with a supply voltage of 10 - 55V DC. Please connect an external DC power supply with an output voltage of 10 - 55V DC to the power supply socket "POW"...
  • Page 11: Setting Up The Sim And Establishing A Connection

    On the tab "Firewall Settings" select the setting "wan: mobile" under "Create / Assign firewall-zone. Confirm your entries by clicking on the "SAVE & APPLY" button. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 12: Online-Test

    To do this, open the browser on your PC and enter a URL known to you in the address field (e.g. www.mc-technologies.net). Access via SSH To access the Linux system of the MC PMRL, you must connect to the same IP address (default: 192.168.0.1) as the web interface. The following access data are required:...
  • Page 13: Change Ip-Address

    4. Press “i” to enter the input mode, and change the line "option ipaddr" in the interface "lan" to the corresponding address. 5. If the MC PMRL is to go online via a router, the line option gateway 'aaa.bbb.ccc.ddd' can be added (with the IP address of the router).
  • Page 14: Ports And Gpio's

    The DC voltage must be between 8 and 30V. Port Description POW - Power supply, negative connection POW + Power supply, positive connection MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 15: Usb-Port 2.0 Typea

    OUT1B DIG_IN_7 OUT1A DIG_IN_6 IN_ADC4- DIG_IN_5 IN_ADC4+ DIG_IN_4 IN_ADC3- DIG_IN_3 IN_ADC3+ DIG_IN_2 IN_ADC2- DIG_IN_1 IN_ADC2+ OUT4B IN_ADC1- OUT4A IN_ADC1+ OUT3B MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 16: Serial

    Now it is possible to communicate with the RS485 port. RX / TX is switched automatically. Finally terminate picocom with Ctrl + a + x. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 17: Configuring Wlan (Master Mode)

    4. Under Interface Configuration -> General Setup, type wanted ESSID for your device. 5. Choose lan for Network 6. Click on SAVE & APPLY. 7. Under WLAN Overview, click on ENABLE. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 18: Create Interface

    7. Under Common Configuration click on Firewall Settings and choose lan or wan (depending on wanted source). 8. Click on SAVE & APPLY. 9. A new interface is created. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 19: Configuring Vlan

    3. Add a name for the interface (example VLAN). 4. Set protocol to DHCP Client. 5. Choose Switch VLAN: “eth0.2” 6. Click on Submit. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 20 7. Under Common Configuration click on Firewall Settings and choose lan. 8. Click on SAVE & APPLY. 9. A new interface is created. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 21  Client certificate (client.crt) and client key (client.key) 11.1 Client Configuration 1. After logging to MC PMRL Luci interface using the IP address (default 192.168.0.1), click on “OpenVPN” under “VPN” tab. 2. Click on “EDIT” at “sample_client” tab. 3. Click on “Switch to advanced configuration”.
  • Page 22 5. Click on “SAVE & APPLY” and then “BACK TO OVERVIEW”. 6. Enable the configured instance , then click on “SAVE AND APPLY”, then “START”. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 23 MC PMRL Mobile Radio Router 11.2 Server Configuration 1. After logging to MC PMRL Luci interface using the IP address (default 192.168.0.1), click on “OpenVPN” under “VPN” tab. 2. Click on “EDIT” at “sample_server” tab. 3. Click on “Switch to advanced configuration”.
  • Page 24 5. Click on “SAVE & APPLY” and then “BACK TO OVERVIEW”. 6. Enable the configured instance, and then click on “SAVE AND APPLY”, then “START”. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49 511 67 69 99-0, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 25 MC PMRL. To reset the MC PMRL:  Locate the Reset button on the back of your MC PMRL device.  Use the pointed end of a paperclip or similar object to press and hold the Reset button.
  • Page 26 14 Disposal 14.1 Return of the old equipment In accordance with WEEE regulations, the return and recycling of old MC Technologies equipment for our customers is regulated as follows: Please send your old devices carriage paid to the following address:...