Tatung TiMS User Manual

Tatung TiMS User Manual

Tatung intelligent motor sensor
Table of Contents

Advertisement

Quick Links

Tatung
intelligent
Motor Sensor
USER MANUAL
Feb. 20, 2020
Version 2.1

Advertisement

Table of Contents
loading

Summary of Contents for Tatung TiMS

  • Page 1 Tatung intelligent Motor Sensor USER MANUAL Feb. 20, 2020 Version 2.1...
  • Page 2: Table Of Contents

    LoRaWan Gateway Model (Optional) ....................13 4.TiMS Monitoring System ....................... 14 TiMS Monitoring System - Monitoring App ..................14 TiMS Monitoring System – Monitoring Cloud Platform ..............14 Monitoring System Features ......................14 5.TiMS Operating Guide ........................16 TiMS User Flow Chart ........................16 Register TiMS Member Account ......................
  • Page 3 Display Settings ..........................39 Appendix I. Epoxy Putty User Guide ..................40 Appendix II. TiMS Website Address & TiMs App Download QR Code ........ 41 Appendix III. Recommended Monitoring Parameters Setting Value ........42 Appendix IV. TiMS Website Sensor Status List ................. 43...
  • Page 4: Notice Information

    TiMS can measure motor data and monitor the motor operating status. After scanning the motor status, all the data are stored in TiMS memory and transmitted to the smart handheld devices ®...
  • Page 5 Warranty * Tatung company provides a warranty against defects in TiMS hardware for a period of 12 months counted from the date of the invoice issued by the factory or distributor/dealer. *...
  • Page 6: Symbol Instructions

    User Manual (English version)_V2.0 * A statement about protection impairment if used in a manner not specified by Tatung company will void all guarantees and could cause permanent damage to the equipment and could lead to property damage, personal injury and/or death.
  • Page 7: Product Disposal Instructions

    At the end of its usable life, the battery is collected as a used electro-electronic device. The TiMS cannot be disposed of in incinerators and city landfills either. It must be disposed of in compliance with the local regulations.
  • Page 8: Tims Specifications

    User Manual (English version)_V2.0 TiMS Specifications 1.1 Applicable Motor Type  Motor:3-Phase squirrel cage induction motor or synchronous motor  Voltage:690V AC below  Drive type:DOL / VFD  Duty cycles:Continuous duty, S1  Environment:Safe area 1.2 Overall Information  Model & Certifications:...
  • Page 9: Range Of Environmental Conditions

    User Manual (English version)_V2.0 1.3 Range of Environmental Conditions  Environment:  Pollution degree:2  Relative humidity:5% ~ 95%R.H. Both dry and wet location use  Altitude:Below 4,000 meters above sea-level  Ambient temperature:-40℃~+60℃ (-40℉~+140℉) Recommended storage and transportation condition:environment temperature range between -40 ℃...
  • Page 10: Tims Hardware

    LoRa Address: xx In package On the sensor shell side The sensor registration process requires the user to key in Product S/N, BLE Name and BLE Address to register on the TiMS monitoring system website by user NOTE account (see section 5.3).
  • Page 11: Sensor Led Light Indication

    User Manual (English version)_V2.0 After the registration process, the user is the only owner of the sensor. Other accounts aren’t able to use or connect the sensor. CAUTION 2.3 Sensor LED Light Indication Status LED light color Indication The light is dark at normal status and becomes green when a Normal magnet...
  • Page 12: Sensor Installation And Setting Tools (Not Included In The Package)

    User Manual (English version)_V2.0 2.4 Sensor Installation and Setting Tools (not included in the package) Small strong magnet such as Neodymium magnet (NdFeB magnet) Phillips screwdriver Hexagon key (No. 4) PU plastic gloves (for epoxy putty mixing) Cleaning objects such as cleaning naphtha, rag, fine sandpaper…etc. (for cleaning the position to install the sensor on the motor frame) 2.5 Sensor Installation Instructions Recommended installation position:...
  • Page 13 User Manual (English version)_V2.0 Illustration Instructions Grind the fins by fine sandpaper and then use rag with cleaning naphtha to scrub the fins. Take an appropriate amount of epoxy putty and knead it about five minutes to make it completely mixed and soft.
  • Page 14: Magnetic Control Switch

    User Manual (English version)_V2.0 2.6 Magnetic Control Switch Magnetic switch position: At the symbol of the x-y-z coordinates on the top side of the sensor shell, put the magnet at the control position to activate the sensor. If the sensor is not activated, move the magnet around the symbol area to find the exact position.
  • Page 15: Tims Communication Techniques

    TiMS Communication Techniques 3.1 Communication Scheme To use the service, in addition to the requirement of the TiMS product or purchasing the exclusive LoRa Gateway, user shall bear the cost of preparing necessary smart handheld device, and ensure the availability of the Internet network with a third-party CAUTION telecommunication service provider.
  • Page 16: Data Storage

    User Manual (English version)_V2.0 *1. [Passive] means the user needs to manually choose the interval to collect all of the periodic measurement data (history data) from every sensor. The data will be uploaded to the cloud automatically by the mobile internet. *2.
  • Page 17: Tims Monitoring System

    TiMS monitoring system includes monitoring App and monitoring cloud platform. The monitoring App may connect smart handheld devices to the TiMS product and operate and adjust the product therewith to read the user data of the product and provide the numbers and applications of the data. Before using the service, the user shall confirm whether or not a smart handheld device could connect to the service or not and read the instructions and relevant provisions.
  • Page 18 App and e-mail if an abnormal situation happened. LoRa non real- time alert threshold value setting: On LoRa mode, the user can modify the alert threshold value on the TiMS website. Ensure the sensor monitoring the motor at the accurate value.
  • Page 19: Tims Operating Guide

    User Manual (English version)_V2.0 TiMS Operating Guide 5.1 TiMS User Flow Chart Enter TiMS website Download & Install Flow chart description Sign up account & get the email TiMS App to activate account App function WEB function Sign in Account &...
  • Page 20: Register Tims Member Account

    User Manual (English version)_V2.0 5.2 Register TiMS Member Account Step 1. Open the TiMS website: https://tatungmotor.azurewebsites.net/ Step 2. Click the [Register] icon to sign up for the member account.
  • Page 21 [Company name]:this is an unique item to recognize and manage the cloud system. [Enter your E-mail]:the E-mail address is the same as [Account]. [Password]:password must be set with at least 8 characters. [I agree to Privacy policy] and [I agree to TiMS terms of service] must be checked. NOTE User shall keep the account and password properly and log out every time after use to prevent it from being stolen.
  • Page 22 User Manual (English version)_V2.0 Step 4. Fill in the account information. All the items are required information. NOTE Step 5. Submit the form and receive the account activation mail. Step 6. Click Activate Account linkage to connect the TiMS website and activate account.
  • Page 23: Sensor Register

    User Manual (English version)_V2.0 5.3 Sensor Register Step 1. Sign in the TiMS website When sign in the account the first time, the user needs to set the time zone. The current time zone will be shown in the message box.
  • Page 24: Lora Gateway Register (Optional)

    Click [Product Information] menu icon. Step 3. Click [Register LoRa GW] to register LoRa gateway(s). Step 4. Key in the Gateway serial numbers shown on the gateway package box or gateway and register it. Tatung GWsn TiMLG-xxxxxxxx Setting Web http://192.168.2.1 XXXXXXXXXXXX admin...
  • Page 25: Tims App Download And Sign In

    User Manual (English version)_V2.0 5.5 TiMS App Download and Sign in Step 5. Use smart handheld devices (such as smart phones and tablets) to download the [Tatung iMotor Sensor] App and install it. iOS & Android App download QR Code shown as <Appendix II.>...
  • Page 26: Sensor Initial Setting

     Before setting the motor information, the user still does nothing to the sensor. The sensor name color in dark is a normal status in this process.  While TiMS App in process, the network connection should be assured. NOTE ...
  • Page 27 User Manual (English version)_V2.0 Step 2. Enable the sensor Bluetooth signal by using a magnet to approach it at least 3 seconds. When the sensor flashes green light 3 times, it means the Bluetooth signal is on. Step 3. Sign in App again, when the sensor name color turns to BLUE, it means the App has searched sensor Bluetooth signal.
  • Page 28: Ble Mode Functions

    User Manual (English version)_V2.0 5.7 BLE Mode Functions  mode, the sensor will auto scan the motor status and record data in the sensor memory.  After the user collects the data via Bluetooth by smart devices, the data will be uploaded to the cloud system automatically.
  • Page 29: Lora Mode Setting & Functions

    User Manual (English version)_V2.0 5.8 LoRa Mode Setting & Functions After the parameter setting, user must continue the LoRa setting to finish the setting process. Step 1. Turn to the [LoRa Setting] page to connect the LoRaWan with LoRa gateway. Step 2.
  • Page 30: Other Tims Monitoring App Functions

    User Manual (English version)_V2.0 Other TiMS Monitoring App Functions 6.1 User Sign in Screen Instructions  Key in user [Account] & [Password] to sign in App.  [I agree to Privacy policy] must be checked.  Change the Password:according to the directions to change the password.
  • Page 31: Motor Information & Monitoring Setting

    6.3 Motor Information & Monitoring Setting App Display of Motor Information & Monitoring Setting Screen Instructions After [Admin permission] account click [modify by App] icon on the TiMS website (see section 7.3(3)), user can modify the motor information on this page.
  • Page 32: Tims Instant Information

     Only in Bluetooth connection status user can trigger [START INSTANT MEASURE].  Before Bluetooth disconnected, the last manually measured data will be uploaded to Tatung Azure Cloud.  In Bluetooth disconnection status, [ON(BLE Mode)] shows the latest instant measurement data uploaded from App.
  • Page 33: History Data & Graph

     Danger Status In Bluetooth disconnection status, the history graph will show the data downloaded from Tatung Azure Cloud.  After downloading the history data, once the graph background color appears yellow (warning) or (danger), the user must go to [Overall Information] page...
  • Page 34: Overall Information

    In Bluetooth connection status, user can click it to enter the analysis page and trigger instant vibration analysis. Otherwise, it will show the latest manual analysis result uploaded to the Tatung Azure Cloud.  [Alerts History]: While abnormal data measured, the sensor will trigger vibration analysis automatically.
  • Page 35: Tims Monitoring Website Functions

    User Manual (English version)_V2.0 TiMS Monitoring Website Functions 7.1 Website Address https://tatungmotor.azurewebsites.net/ 7.2 Home Page Account sign in and register. 7.3 Device Status  First page displays all the device/equipment's latest status.  The sensor status icon list shown as <Appendix...
  • Page 36: Tims Monitoring Information

    User Manual (English version)_V2.0 7.4 TiMS Monitoring Information Instant Status i. Motor Brief Information ii. Latest Monitoring Information (the same as that shown in App) iii. History Graph (the display area can be changed and adjusted.) iv. Upload device/equipment photos...
  • Page 37 User Manual (English version)_V2.0 Alerts list, Vibration analysis data & Regular Maintenance.  Click [Vib. Analysis Data] to check vibration analysis result uploaded from App.
  • Page 38 User Manual (English version)_V2.0 Equipment Information  User can modify the motor information on this page or App.
  • Page 39 User Manual (English version)_V2.0 Monitoring Setting  Users can modify the Alert threshold (warning or danger) value by LoRa gateway on this page.  LoRa alert setting function can only be used on LoRa mode. CAUTION  After the LoRa alert setting, the setting function will be locked until the sensor receives the command and responds to the setting result.
  • Page 40: Sensor Report Download

    User Manual (English version)_V2.0 7.5 Sensor Report Download  Users can download the sensor report (PDF file) and data (CSV file) on this page. 7.6 User Permission Account Setting  In [Admin permission] user can add, modify and delete the [User permission] account in this page.
  • Page 41: Monitoring Permission

    User Manual (English version)_V2.0 7.7 Monitoring Permission  Users can enable or disable the alert notification function on this page. 7.8 Account Information  Users can see and modify the account information on this page.
  • Page 42: Password Change

    User Manual (English version)_V2.0 7.9 Password Change  Users can change account password on this page. 7.10 Display Settings  Users can change display language or unit by click this icon.
  • Page 43: Appendix I. Epoxy Putty User Guide

    User Manual (English version)_V2.0 Appendix I. Epoxy Putty User Guide...
  • Page 44: Tims Website Address & Tims App Download Qr Code

    User Manual (English version)_V2.0 Appendix II. TiMS Website Address & TiMs App Download QR Code TiMS website https://tatungmotor.azurewebsites.net/ for iOS system for Android system...
  • Page 45: Recommended Monitoring Parameters Setting Value

    User Manual (English version)_V2.0 Appendix III. Recommended Monitoring Parameters Setting Value Periodic measurement (Automatically Scan) setting Item Recommended setting Auto measuring ON (BLE Mode) Measuring Frequency 1 time(s)/hr Measuring Start Time current time Abnormal temperature setting App will automatically display the proper value according to [Insulation class] in the setting of [Motor Information].
  • Page 46: Tims Website Sensor Status List

    User Manual (English version)_V2.0 Appendix IV. TiMS Website Sensor Status List Status Indication Color Background Device Power ON Green Device Power OFF Black No Data (Factory Default) Light Grey Temp. Abnormal Temperature Temp. Temp. Yellow / Red Vib.X Abnormal X-axis Vibration Vib.X...
  • Page 47 22 Chongshan N. Road, 3rd Sec., Taipei, 10435 Taiwan Tel: +886-2-2599-5429, 886-2-2592-5252 ext. 2403, 2489, 2908 Fax:+ 886-2-2598-4427 E-mail: service@sansha.tatung.com.tw Web: www.tatung.com Tatung Electric Company of America, Inc. 14381 Chambers Road, Tustin, CA 92780, USA Tel: +1-714-8383293~4 Fax:+1-714-8383295 E-mail: sales@tatungelectric.com Toll Free 800-828-8641 Web: www.tatungelectric.com...

Table of Contents