Set-up parameters configuration

3.9
The set-up configuration parameters section is accessed from the
management page of the device/slave you want to configure by clicking
DESCRIPTION
1 Selector to enable (left selector) or disable (right selector) the modification of parameters
2 Icon indicating whether the device is in manual mode
3 Buttons to expand or close the window
4 Parameters to be configured (they vary according to the type of device/slave selected)
5 Button to send the reset command (restore to factory default settings). Also available with selector [1] configured on the right
6 Button to save a configuration without sending it to the device
7 Button to send the configuration
8 Button to Send the command in order to finalise the current configuration on the device/slave
Upon accessing the system for the first time after connecting a new
device, since no configuration has been saved yet, the parameters sent
by the device will be shown on screen regardless of the type of display
selected.
Even if a device is not connected, it is still possible to access its
configuration, but only the display of the parameters will be enabled
and the only possible option will be to save the configuration without
sending it to the device.
on the "Configuration" button under the image of the device/slave.
If the value of a parameter displayed on the screen differs from that in
the connected device/slave, the symbol
parameter. By clicking on it, the value displayed on the screen is aligned to
the current value on the connected device/slave.
To be able to send the Reset, Send and Save on device commands to the
selected device/slave, the device must be in manual operating mode. You
can see if the device is in manual mode by checking the icon [2].
device in manual operating mode
device not in manual operating mode