Error Codes
When a detectable failure occurs, the fail bit is set and the failure code
is populated. the failure codes have the following meaning:
Code Number
Meaning
0-5 mA
No failure
6-8 mA
Power Supply out of Tolerance
8-10 mA
Copper out of Range
10-12 mA
Silver out of Range
12-14 mA
Gold out of Range
14-16 mA
Self diagnostic, failed replace board
16-18 mA
Invalid time/date
18-20 mA
Other errors

11.0 SAAFShield Parts List

It is recommended that the following spare parts be stored at the
installation site for replacement purposes. Consult with your AAF
representative to determine actual quantities required.
Description
Detecting Unit (DU)
Silver Sensor
Gold Sensor
Copper Sensor
Reading Unit (RU)
Connection Cable (DU-RU)
12V Adaptor
Communications Module (CM)
- configured for Legacy
- configured for RoHS
- configured for Museum
Connection Cable (DU-CM)
to order replacement parts call: 1-800-AAF-2003.
Part Number
392-803-101
392-803-010
392-803-011
392-803-012
392-803-001
392-803-003
392-803-000
392-803-510
392-803-520
392-803-530
392-803-004