VideoSys IDU-E User Manual

VideoSys IDU-E User Manual

Camera control indoor unit

Advertisement

IDU-E User Manual
Revision v8 - 18.09.20
Videosys Broadcast Ltd
Unit 1-2 Forest Barn Farm
Turners Hill Road
Turners Hill
West Sussex
RH10 4QH
UK
T: +44 (0)1293 541 200
E: sales@Videosys.tv
W: www.Videosys.tv
The information contained in this document is the property of Videosys Broadcast Ltd. This document and the
information contained herein is provided for evaluation purposes only and is subject to change without notice.
Videosys Broadcast Ltd assumes no responsibility for errors that might appear in this document and gives no
representations or warranties as to the accuracy of the information contained herein, including but not limited to
the suitability and performances of the product or its intended application.
1
© Copyright Videosys Broadcast Limited 2018. All Rights Reserved. (Version 8.0)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDU-E and is the answer not in the manual?

Questions and answers

Summary of Contents for VideoSys IDU-E

  • Page 1 West Sussex RH10 4QH The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 2: Table Of Contents

    Physical Parameters Dimensions, Electrical Parameters The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 3: Camera Control Indoor Unit

    (3 Pin XLR, Female) Legacy Camera Connectors (‘Generic’ or ‘Sony’) The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 4: Principal Of Operation

    The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 5: Connecting Components

    The following diagrams are from the point of view of the rear panel of the IDU facing the user. The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 6: Navigating Menus

    Panel Connection Status Camera Connection Status The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 7 For a full description of BiDi setup please consult the BiDi Quick Start guide available on our website www.Videosys.tv. The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 8: Menu Structure

    Paint settings reset and version information. CAMERA MANUFACTURER The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 9 SYSTEM The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice. E: sales@Videosys.tv...
  • Page 10 NETWORK CAMERA NUMBERS The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 11: Menu Item Descriptions

    BiDi Ethernet Return - Allows the user to decide which ports the reverse data will input to the IDU, 4 channel operation the return ports are 1-4 or 2 channel operation the return ports are 2 and 4. The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 12 IP panel connections as some manufacturers use the camera number to identify the panel to camera data connection. The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 13: Web Interface

    Videosys default IP address for the IDU is 192.168.1.200. Fig 4. The IDUs Maintenance Webpage The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 14: Navigating The Web Interface

    Fig 5. The IDUs Front Panel Webpage Fig 6. The IDUs Remote Panel Webpage The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 15: Supported Cameras And Commands

    The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.
  • Page 16: Physical Parameters

    Temperature Range: 0-50 °C Sound Output: 0db - Fanless The information contained in this document is the property of Videosys Broadcast Ltd. This document and the T: +44 (0)1293 541 200 information contained herein is provided for evaluation purposes only and is subject to change without notice.