ECI MOVFR-LCD Installation Manual Table of Contents Warning and Disclaimer ........................5 Introduction ............................6 Conventions Used ..........................6 Safety Information ..........................7 System Overview ..........................8 Control Board ..........................8 5.1.1 Electrical ..........................8 5.1.2 Connections ........................... 8 5.1.2.1 Input Signals ........................
Page 4
8.2.1 Right Hand CAMs ......................25 8.2.2 Left Hand CAMs ......................... 26 AUTO Operation ..........................26 Drill template for MOVFR-0001N replacement ................27 Electronic Controls, Inc. 7073 North Atlantic Ave. Cape Canaveral, FL 32920 800-633-9788 www.eciamerica.com P a g e...
ECI MOVFR-LCD Installation Manual 1 Warning and Disclaimer Thank you for purchasing equipment from ECI America, INC. We want your new equipment to operate safely. Anyone who installs or uses this equipment should read this publication (and any other relevant publications) before installing or operating the equipment.
The ECI MOVFR (Variable Frequency Drive) LCD Door Operating system is a 2 board combination designed to be a drop in replacement for the GAL MOVFR door operator. The ECI VFD LCD door operator includes a 230VAC input Variable Frequency Drive (VFD) board and a control board with key pad and LCD screen.
ECI MOVFR-LCD Installation Manual 4 Safety Information Know the safety hazards related to any procedure you are about to perform. Know what equipment has been specified for each specific contact and know what tools and materials you should plan to have available. Before connecting electrical wiring, take precautions to prevent accidents from happening to yourself and others around you.
ECI MOVFR-LCD Installation Manual 5 System Overview 5.1 Control Board Figure 1 - Control Board 5.1.1 Electrical 5.1.2 Connections 5.1.2.1 Input Signals • CLOSE – Any 24 to 240 VAC/VDC input between CLOSE and COM will produce a CLOSE operation.
ECI MOVFR-LCD Installation Manual • REOPEN NO • REOPEN COM REOPEN Relay contacts rated at 230V 10A. Energized • REOPEN NC when torque limit exceeded, obstruction of light curtain. • DCL NO • DCL COM DCL Relay. Door Close Limit contacts rated at 230V 10A. Energized when •...
ECI MOVFR-LCD Installation Manual Figure 4- Tri-Tronics® wiring 5.1.3 User Interface 5.1.3.1 LCD Screen Main Menu ECI MOVFR (C) 2018 ECI Inc. Edit parameters Load defaults Diagnostics 1 Diagnostics 2 Figure 5 - LCD Screen Main Menu Figure 5 - LCD Screen shows the main menu. Pressing the “-“ button moves the curser down to the next selection.
ECI MOVFR-LCD Installation Manual • SSO – Slow Start Open. Speed setting is OP slow start. When illuminated indicates the start of the open cycle when the interlock rollers unlock hoistway door. SSO/FSO sensor blocked and MSO sensor open during an OPEN cycle.
ECI MOVFR-LCD Installation Manual • AUTO / MAN – 2 position switch. AUTO position is for normal operation. MAN position is for controlling the doors using OPEN, CLOSE, HEAVY and NUDGE switches. • CLOSE / OPEN – 3 position switch. Center position no function. With AUTO/MAN switch in manual position this controls opening and closing the doors.
Page 13
ECI MOVFR-LCD Installation Manual CAUTION: Holding power should be set less than 15W to prevent motor heating which will reduce motor life. • CL hold sp. – Enabled when the door reaches DCL and the parameter is greater than 0.
ECI MOVFR-LCD Installation Manual • OP decel – A lower value produces a quicker deceleration. This should be set so the OP Final Speed FSO is reached before the DOL and OPEN stop roller to prevent slamming and bouncing. The default setting is 50. Min is 1 and max is 100.
ECI MOVFR-LCD Installation Manual 5.1.5.1.3 Input Voltage setting Parameter • Input voltage – Parameter for setting valid AC/DC voltage for CLOSE, OPEN, NUDGE and HEAVY inputs. Default setting is 24. Minimum is 12 and max is 240. Voltages below these settings will not be detected by the control board.
• Disconnect power from drive. • Remove Control board and Drive shown in Figure 10 - MOVFR-0001N (shown without CAMs) Figure 10 - MOVFR-0001N • Remove the standoffs indicated in Figure 11 - Standoff Removal leaving the 2 standoffs on the far right and the 2 nylon standoffs in the center.
Page 18
ECI MOVFR-LCD Installation Manual Remove Keep Figure 11 - Standoff Removal Figure 12 - Snapping Off Standoff • Remove drill template from manual (last page of manual). Fold or cut page of drill template along dotted lines and place in top left corner of operator as shown in Figure 13 - Drill Pattern placement Electronic Controls, Inc.
Page 19
Figure 14 - Standoff Placement • Using hardware supplied with the board, mount the Control and Drive boards as shown in Figure 15 -ECI MOVFR LCD Installed. Connect communication cable (supplied with boards) between Control and Drive boards. Electronic Controls, Inc.
• Remove the Control Board and Drive shown in Figure 17 - MOVFR-0069N • Mount and secure the ECI MOVFR-LCD Control board and Drive board as shown in Figure 18 - ECI MOVFR-LCD Installed. • Connect communication cable (CAT5) between Control and Drive Boards.
Page 21
ECI MOVFR-LCD Installation Manual Figure 17 - MOVFR-0069N Figure 18 - ECI MOVFR-LCD Installed Electronic Controls, Inc. 7073 North Atlantic Ave. Cape Canaveral, FL 32920 800-633-9788 www.eciamerica.com P a g e | 21...
ECI MOVFR-LCD Installation Manual 7 Initial Power Up and Test 7.1 Manual Operation • With the doors in the fully closed position and the AUTO/MAN switch in the MAN position, apply power to door operator o LCD Display should show...
ECI MOVFR-LCD Installation Manual ▪ When fully OPEN the SPEED and MOTOR reading should go to 0 even with the switch in OPEN position. o NOTE that the HOLDING LED will not light as the OP HOLD SP and TORQ settings are at default 0 settings.
ECI MOVFR-LCD Installation Manual 8.1.4 Open CAM/Sensor Sequence Figure 22 - OPEN CAM/SENSOR Sequence 8.2 CAM Settings 8.2.1 Right Hand CAMs Figure 23- Right Hand CAM Settings Electronic Controls, Inc. 7073 North Atlantic Ave. Cape Canaveral, FL 32920 800-633-9788 www.eciamerica.com...
ECI MOVFR-LCD Installation Manual 8.2.2 Left Hand CAMs Figure 24 - Left Hand CAM Settings 9 AUTO Operation • Go to EDIT PARAMETERS and change the INPUT VOLTAGE parameter to the proper voltage for your system. • Switch the AUTO/MAN switch to AUTO position.
ECI MOVFR-LCD Installation Manual 10 Drill template for MOVFR-0001N replacement FOLD OR CUT PAGE ALONG DOTTED LINES Electronic Controls, Inc. 7073 North Atlantic Ave. Cape Canaveral, FL 32920 800-633-9788 www.eciamerica.com P a g e | 27...