glasmacher electronic TGM 5 Instruction Manual

glasmacher electronic TGM 5 Instruction Manual

Door closing meter

Advertisement

TGM 5 Door Closing Meter

Instruction Guide
12.18
glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany
email@glasmacher-electronic.de • www.glasmacher-electronic.de •  +49 2375 688 •  689

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TGM 5 and is the answer not in the manual?

Questions and answers

Summary of Contents for glasmacher electronic TGM 5

  • Page 1: Tgm 5 Door Closing Meter

    TGM 5 Door Closing Meter Instruction Guide 12.18 glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de •  +49 2375 688 •  689...
  • Page 2: Table Of Contents

    Output Voltage Range and Measured Value Scale..........23 Measurement direction and Output Signal..............23 Automatic shutdown....................24 Analog Port and Analog Connection Cable............24 Known problems.....................24 glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 3: Tgm 5 Door Closing Meter

    TGM 5 Door Closing Meter Final remark......................24 Technical specifications..................26 Cycle of calibration....................27 Brief instruction for measuring ................28 Brief instruction for testing..................29 glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 4: Introduction

    Task The Door Closing Meter TGM 5 is a helpful device for checking the production quality in the car industry. The closing speed is an objective measure of the quality of the car door.
  • Page 5: Scope Of Supplies

    • Instruction Guide • Calibration certificate Setup The Door Dlosing Meter TGM 5 consists of a control unit and a measurement sen­ sor, which are connected via a cable. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany...
  • Page 6: Measurement Sensor

    These stands are the „TGM Magnetic Holder“ and „TGM Suction Cup“. Both can be ordered under these designations. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 7 BOHLE (42781 Haan, Germany) of­ fers a large range of suction cups. The TGM suction cup glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 8 (12105 Berlin, Germany). So with this rubber-coated magnet, the measurement sensor can be mounted quickly and reliably on the car. Due to the electronic design of the TGM 5 Door Clo­ sing Meter, the measurement sensor can only measure magnetizable objects. There is a „TGM Measurement Edge“...
  • Page 9: Control Unit

    When the white and green buttons are pressed simultaneously the serial number of the TGM 5 is displayed. The serial number is also found in the battery compartment. This instruction guide and the specifications of the TGM 5 can be downloaded as a PDF file from the website tgm.glasmacher-electronic.de.
  • Page 10: Switching On

    Switching off The device is switched off by pressing the white button until the LCD displays "OFF". Release. To conserve the battery, the TGM 5 automatically switches off after 5 minutes of inactivity. The last measured values are deleted. Display...
  • Page 11: Operating Modes

    4. The default value for the or green value is displayed with an down- or upward-pointing arrow. The percent sign "%" indicates that the TGM 5 is in the "value adjustment" mode. 5. With a short or long press on the green button, the value will now be reduced or increased.
  • Page 12: Testing" Mode

    Meausred Speed in the target range Directly after the measurement, no keys necessary Battery voltage ◌ ● Serial number ◌ ● glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 13: Measuring" Mode

    Push if: Door is closed Flash ● Speed determined, successful Permanent measurement Battery voltage ◌ ● Serial number ◌ ● glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 14: Precision Value Vdelta

    V is smaller or diff equals the preset precision value delta glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 15: Example „Measure

    2. Measurement Display: 0.97 m/sec (= door speed) The door is not closed, the tester presses the red button . glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 16 8. Measurement Display: 1.18 m/sec (= door speed) The door is not closed, the tester presses the red button. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 17: Power Supply And Charger

    12 V= . The TGM 5 control unit works with an internal voltage of 3.3 V=, the sensor with 5 V =. The factory-supplied 8.4 V block battery (type: ANS 300) is charged by a regulated current and can not be overloaded or damaged if the included 12 volt battery charger is used.
  • Page 18: Accumulator / Battery

    “ANSMANN”. Charging the TGM 5 is very simple and effective; I-charging with I_10 = 30 mA, so that the accumulator of the TGM 5 cannot be damaged by overcharging, for example on a weekend. A capacity of 300 mAh is sufficient for a (theoretical) operating time of 37 hours.
  • Page 19: Calibration

    -40 ° C to + 85 ° C. • The control unit of the TGM 5 is prepared for the installation of a digital / analog converter to output a voltage value correspondig to the door speed reading on the LC display.
  • Page 20: Option: Tgm/Usb

    +3.3/0 V The TGM/USB cable contains integrated electronics in the USB plug that ad­ apts the USB signal levels for the TGM 4 or TGM 5 and converts the simple RS232 protocol into the complex USB protocol. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany...
  • Page 21: Installation Of Usb Drivers For Windows Xp

    TGM which is connected via the USB. When you have determined the door-locking speed, press the white button on the TGM. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 22: Concluding Remarks

    TGM  Door-locking speed 5.) ! Press the white button on the TGM PC  Door-locking speed TGM  „0,00“ glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 23: Option: Analog Output

    TGM 5 Door Closing Meter Option: Analog Output The TGM 5 analysis device is equipped with an analog-output to represent the TGM5 door speed as a voltage. For versions with the Analog-Output option, the printed label also bears the letter “A”, for example TGM-A + serial number.
  • Page 24: Analog Port And Analog Connection Cable

    If it happens, that the TGM 5 doesn't switch on despite pressing a button, open the battery compartment, disconnect the battery clip, wait a few seconds and then re-connect the battery again.
  • Page 25 We will do our best to help you. If necessary we can adapt the TGM 5 to your special needs or develop and supply special measurement devices for new tasks.
  • Page 26: Technical Specifications

    60 * 60 * 30 mm Connection cable: Weight: Control unit: 230 g (incl. accumulator) Measurement sensor: 60 g glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 27: Cycle Of Calibration

     The demands on the devices.  Regulations of the quality assurance department in the company. Because of the above mentioned reasons, a re-adjustment of the TGM 5 door clo­ sing meter is not absolutely necessary. Nevertheless it is advisable to check the de­...
  • Page 28: Brief Instruction For Measuring

    ? yes : door speed determined!  door speed ! press the white button 6.) ! release button  " 0.00" glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...
  • Page 29: Brief Instruction For Testing

    4.) ? door speed within the permissible range ?  door speed ? green LED off: back to 2.) ? green LED on : Door o.k. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de  +49 2375 688 •  689...