Output Voltage Range and Measured Value Scale..........23 Measurement direction and Output Signal..............23 Automatic shutdown....................24 Analog Port and Analog Connection Cable............24 Known problems.....................24 glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de +49 2375 688 • 689...
Task The Door Closing Meter TGM 5 is a helpful device for checking the production quality in the car industry. The closing speed is an objective measure of the quality of the car door.
• Instruction Guide • Calibration certificate Setup The Door Dlosing Meter TGM 5 consists of a control unit and a measurement sen sor, which are connected via a cable. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany...
These stands are the „TGM Magnetic Holder“ and „TGM Suction Cup“. Both can be ordered under these designations. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de +49 2375 688 • 689...
Page 7
BOHLE (42781 Haan, Germany) of fers a large range of suction cups. The TGM suction cup glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de +49 2375 688 • 689...
Page 8
(12105 Berlin, Germany). So with this rubber-coated magnet, the measurement sensor can be mounted quickly and reliably on the car. Due to the electronic design of the TGM 5 Door Clo sing Meter, the measurement sensor can only measure magnetizable objects. There is a „TGM Measurement Edge“...
When the white and green buttons are pressed simultaneously the serial number of the TGM 5 is displayed. The serial number is also found in the battery compartment. This instruction guide and the specifications of the TGM 5 can be downloaded as a PDF file from the website tgm.glasmacher-electronic.de.
Switching off The device is switched off by pressing the white button until the LCD displays "OFF". Release. To conserve the battery, the TGM 5 automatically switches off after 5 minutes of inactivity. The last measured values are deleted. Display...
4. The default value for the or green value is displayed with an down- or upward-pointing arrow. The percent sign "%" indicates that the TGM 5 is in the "value adjustment" mode. 5. With a short or long press on the green button, the value will now be reduced or increased.
Meausred Speed in the target range Directly after the measurement, no keys necessary Battery voltage ◌ ● Serial number ◌ ● glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de +49 2375 688 • 689...
12 V= . The TGM 5 control unit works with an internal voltage of 3.3 V=, the sensor with 5 V =. The factory-supplied 8.4 V block battery (type: ANS 300) is charged by a regulated current and can not be overloaded or damaged if the included 12 volt battery charger is used.
“ANSMANN”. Charging the TGM 5 is very simple and effective; I-charging with I_10 = 30 mA, so that the accumulator of the TGM 5 cannot be damaged by overcharging, for example on a weekend. A capacity of 300 mAh is sufficient for a (theoretical) operating time of 37 hours.
-40 ° C to + 85 ° C. • The control unit of the TGM 5 is prepared for the installation of a digital / analog converter to output a voltage value correspondig to the door speed reading on the LC display.
+3.3/0 V The TGM/USB cable contains integrated electronics in the USB plug that ad apts the USB signal levels for the TGM 4 or TGM 5 and converts the simple RS232 protocol into the complex USB protocol. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany...
TGM which is connected via the USB. When you have determined the door-locking speed, press the white button on the TGM. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de +49 2375 688 • 689...
TGM 5 Door Closing Meter Option: Analog Output The TGM 5 analysis device is equipped with an analog-output to represent the TGM5 door speed as a voltage. For versions with the Analog-Output option, the printed label also bears the letter “A”, for example TGM-A + serial number.
If it happens, that the TGM 5 doesn't switch on despite pressing a button, open the battery compartment, disconnect the battery clip, wait a few seconds and then re-connect the battery again.
Page 25
We will do our best to help you. If necessary we can adapt the TGM 5 to your special needs or develop and supply special measurement devices for new tasks.
The demands on the devices. Regulations of the quality assurance department in the company. Because of the above mentioned reasons, a re-adjustment of the TGM 5 door clo sing meter is not absolutely necessary. Nevertheless it is advisable to check the de...
4.) ? door speed within the permissible range ? door speed ? green LED off: back to 2.) ? green LED on : Door o.k. glasmacher electronic GmbH • Hof Sonnenborn • 58802 Balve • Germany email@glasmacher-electronic.de • www.glasmacher-electronic.de +49 2375 688 • 689...
Need help?
Do you have a question about the TGM 5 and is the answer not in the manual?
Questions and answers