Download Print this page

Advertisement

Quick Links

LSP-HD System
Mountings & Accessories
Installation Guide
Publication Nº 805384
Issue 14
Language: English
09 January 2017
© Land Instruments International, 2017

Advertisement

loading
Need help?

Need help?

Do you have a question about the LSP-HD Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ametek Land LSP-HD Series

  • Page 1 LSP-HD System Mountings & Accessories Installation Guide Publication Nº 805384 Issue 14 Language: English 09 January 2017 © Land Instruments International, 2017...
  • Page 2 IMPORTANT INFORMATION - PLEASE READ Health and Safety Information Read all of the instructions in this booklet - including all the WARNINGS and CAUTIONS - before using this product. If there is any instruction which you do not understand, DO NOT USE THE PRODUCT.
  • Page 3 Web: www.landinst.com For further details on all AMETEK Land offices, distributors and representatives, please visit our websites. Return of Damaged Goods IMPORTANT If any item has been damaged in transit, this should be reported to the carrier and to the supplier immediately.
  • Page 4 Blank...
  • Page 5: Table Of Contents

    Installation Guide LSP-HD Mountings & Accessories Contents INTRODUCTION SYSTEM OVERVIEW LSP-HD Cable assembly SUMMARY OF SPECIFICATIONS MAINTENANCE INSTALLATION DIAGRAMS System Components Preface...
  • Page 6 LSP-HD Mountings & Accessories Installation Guide Blank Preface...
  • Page 7: Introduction

    Installation Guide LSP-HD Mountings & Accessories Introduction This document provides installation details for the range of mountings and accessories for Landscan LSP-HD Scanners. Note The equipment must be used, maintained and serviced by properly trained personnel, capable of following the procedures given in these instructions.
  • Page 8: System Overview

    LSP-HD Mountings & Accessories Installation Guide System Overview It is important to check the equipment with which you have been supplied and then read these instructions thoroughly before proceeding with operation. LSP-HD Cables Power Supply (Optional) Accessory Plate Mounted Blower unit Floatline services cable Mounting Accessory...
  • Page 9: Lsp-Hd Cable Assembly

    Installation Guide LSP-HD Mountings & Accessories The LSP-HD I/O Processors comprise a choice of: • LSP-HD I/O Processor 1 (Land Part Nº 805773) – 4 digital in, 4 digital out, 2 analogue in, 4 analogue out • LSP-HD I/O Processor 2 (Land Part Nº 805774) - 8 digital in, 12 digital out, 4 analogue in, 12 analogue out •...
  • Page 10 LSP-HD Mountings & Accessories Installation Guide Unscrew the innermost knurled ring from the main body of the connector. Slide the main body of the connector down the length of the cable a little. Note down the wiring schedule of the four conductors, then using a small flat object such as a screwdriver, prise up the securing mechanism...
  • Page 11 Installation Guide LSP-HD Mountings & Accessories 2.1.2 Binder Connector disassembly Unscrew the threaded clamp ring which holds the cable and terminal block in the main body of the connector. Unscrew the inner metal clamp ring and slide the plastic clamp and inner rubber washer along the cable.
  • Page 12 LSP-HD Mountings & Accessories Installation Guide When re-assembling the connector, make sure that the terminals are orientated so that the locating notch in the connector is in the position shown in the illustrations. Orientation of notch on connector View inside rear of connector Reposition the lid of the connector shell, ensuring the thin rubber seal is seated correctly on the lid.
  • Page 13: Summary Of Specifications

    Installation Guide LSP-HD Mountings & Accessories Summary of Specifications Blower (Land part Nº 099.471) Operating Temp Range: -40 to 50°C / -40 to 120°F Sealing: IP65 with cover fitted Weight: 28.5 kg / 63lb Refer to the Blower Unit User Guide for full details Basic Mounting Plate (Land Part Nº...
  • Page 14 LSP-HD Mountings & Accessories Installation Guide Landscan LSP-HD Power Supply Unit (PSU) (Land Part Nº 805037) Operating Temp Range: 5 to 50°C Voltage range: 100 to 240V Frequency range: 50 to 60Hz Sealing: IP65 Environment: Indoor use only Warning The PSU is designed to be mounted vertically on a wall or other appropriate structure.
  • Page 15: Maintenance

    Installation Guide LSP-HD Mountings & Accessories Maintenance Warning The safe operation of the service panel is only guaranteed when Land-specified blowers are connected to the blower terminals. The body of the accessories and mountings can be cleaned by wiping with a clean cloth moistened with either water or a mild, neutral detergent. DO NOT use alcohol, chemicals or abrasive cleaning products.
  • Page 16 LSP-HD Mountings & Accessories Installation Guide Blank Page 10...
  • Page 17: Installation Diagrams

    Installation Guide LSP-HD Mountings & Accessories Installation Diagrams This section of the Installation Guide contains a series of installation drawings, covering the installation of the LSP-HD and its mountings, accessories and services. 5.1 System Components 740-069 Light Floatline System Component Land Part Nº...
  • Page 40 Land Instruments International Ltd • Dronfield S18 1DJ • England • Tel: +44 (0) 1246 417691 • Fax: +44 (0) 1246 410585 Email: land.enquiry@ametek.com • www.landinst.com AMETEK Land, Inc. • 150 Freeport Rd. • Pittsburgh, PA 15238 • U.S.A. • Tel: +1 (412) 826 4444 Email: irsales@ametek.com • www.ametek-land.com MARCOM0411 For a complete list of our international offices, please visit www.landinst.com...