Mounting Input/ Output Connections Ground post Power Supply HT Outputs Remote On/Off Output / Input Signals Using the 994IML Specification CE Approval Maintenance Repairs And Warranty 994IML Static Generator Case and Mounting Detail Products shown in this document may be covered by one or more patents, patents applied for and/or registered designs and/or trade marks. For further information please refer to our Head Office or visit www.meech.com.
Introduction The Meech 994IML High voltage generator has been designed to work with the Hydra In-Mould Label pinning system. It provides 0-20kV, Negative polarity, in a lightweight package, powered by 24V DC Full local and remote control makes it ideal for systems integrators, OEMs and end users alike.
Inspection The Model 994IML was carefully packed at our factory to protect it from accidental damage. Nevertheless, we recommend careful examination of the carton and contents for any damage. If damage is evident, do not destroy the carton or packing material and immediately notify the carrier of a possible damage claim. Shipping claims must be made by the consignee to the delivering carrier.
Features Front Panel 1. Power LED Overload LED 2. HT On LED Rotary Voltage Control Side Panel 2 3 4 5 6 1. Ground post 8 Way Mini DIN Control interface 2. On/Off Switch Remote On/Off. 24V DC Inlet. Centre Positive HT Outputs.
Installation Important. The 994IML must be electrically grounded. Failure to do so will damage the unit. Grounding can be achieved either by using the ground post or by using a grounded 24V supply or both. Power Supply 24V DC 994IML 220V AC Grounding using...
Input/ Output Connections Ground post To avoid damage, the 994IML must be grounded. Whether or not the electrical supply is grounded (see page 6), it is strongly recommended that the 994IML should be grounded using this post. Power Supply 2.1mm. Centre positive. 24V. A plug with solder terminals is supplied for the customer’s use.
Output / Input Signals The 8 Way Mini DIN connector offers the following connections: Function 2 Metre Cable 5 Metre Extension Cable Terminal 1 Ground (0V) Black Orange Voltage control Terminal 2 Brown 0-5V = 0-20kV Output voltage setting Terminal 3 Yellow 0-5V = 0-20kV Remote ON/OFF. OFF Terminal 4 Orange Purple when grounded (lo)
Using the 994IML The 994IML can be used very simply with local control of the voltage and monitored using the front panel LEDs. For more sophisticated installations, the output voltage can be controlled via a 0-5 Volt analogue input. Remote monitoring of the output voltage and current is also provided by 0-5V analogue outputs. The state of the HT output is reported via a 5V signal. In-built protection circuitry will prevent the output from exceeding 500mA, by limiting the output voltage. When the protection is in operation the front panel LED will illuminate...
Specification Dimensions 215 x 170 x 46mm (W x H x D) Weight 500g Supply 24V DC, 750 mA Max Output Voltage 0 - 20kV Negative Max Output Current 500 microAmps CE Approval An EC declaration of conformity for this product exists in respect of the Low Voltage Directive: 72/23/EEC (“LVD”) & Electromagnetic Compatibility Directive: 89/336/EEC (“EMCD”)
Repairs And Warranty The 994IML Static Generator is warranted by Meech Static Eliminators Ltd to the original purchaser against defects in material and workmanship for one year after purchase. Should any malfunction occur, please return the unit directly to Meech Static Eliminators or your local distributor.
Need help?
Do you have a question about the 994IML and is the answer not in the manual?