Page 1
IR-CAM-160-P4 Infrared Body Surface Temperature Rapid Screening Camera (Thermal Imaging Camera) User Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC. 3.20...
Page 2
To Users 用 户 Dear Users, Thanks for choosing the Online Monitoring Thermal Imaging Cores. Please read this user manual carefully before first use. Also please keep it in a safe place for reference in the future. Please operate it according to the recommended instructions in user manual.
Page 3
WARNING KEEP THE CORE FROM DAMP OR RAIN! DO NOT OPEN OR EXCHANGE PARTS! REPAIR ONLY CAN BE CONDUCTED BY OUR STUFF! C A U T I O N S In order not to cause malfunctions or even damages for the device, please do not direct the lens towards strong high-temperature radiation source (i.e.
1. Introduction It is the Thermal Imaging Core. It is equipped with Uncooled Focal Plane Array (FPA) Micro-bolometer which can produce intuitive thermal images for users by conveying the infrared ray of objects. And it applies IVE image enhancement algorithm to produce clear images. Besides, the Ethernet RJ45 interface is used for video transmitting or controlling, and the SMA analog video interface is used for displaying the analog image.
2. Power supply The recommended power supply is DC 12V/2A. And the range of power supply is between 10V to 14V. The cores are equipped with protection of over-voltage and over low voltage. And it has the protection of reverse connection.
3.2 The Accessories Figure 3-2 SMA Video: The interface of SMA Video. It can display the analog images. The Pins from the left to the right are Pin1 to Pin10. RJ45 Internet: The interface of Ethernet RJ45. It has many ...
Page 8
Industrial Terminal: There are many functions. For example, it is available for RS232 pin and Reserved I/0 pin. And it has the alarm function. According to needs, users can connect the core to other device by the mounting hole. Transfer SMA to BNC: It is compatible with SMA Video.
Page 9
Notes: (1) Power Input: 10V~14V. (2) AV Video Output Mode: PAL and NTSC are both available. (3) Polarity switching is also for the color bar switching. (4) Zoom ratio: 1X, 2X, 4X. (5) Trigger the Video PIN, start recording video. Trigger the Video Pin again, stop recording.
3.3 The Installation Figure 3-3 UNC 1/4-20 Threaded Hole: It can be fixed in tripod or others bracket. 2*M3 Threaded Hole: It can be fixed in tripod or others bracket. There are 6 holes in total, 2 in bottom, 2 in left and 2 in right side.
4. Technical Specifications Type Uncooled FPA detector IR Resolution 384×288 Detector Pixel Pitch 17μm Data Spectral Range 7.5~14μm NETD 80mk Focus Auto/Motor 24°×18° Lens Data IFOV 1.13mrad Lens 15mm lens Image Enhancement IVE image enhancement algorithm Frequency 50Hz/60Hz Electronic Zoom 2×, 4×...
Page 14
Continuous: Technical Specifications Temp Data MGT format, IRSEEX software to analyze MGS format, IRSEEX software to playback Temp Data with timeline. It can adjust speed, frozen, Flow loop playback and process playing image JPG format (Core), Image BMP and JPG format (PC) Storage Data Video...
5. IRX Software Operation 5.1. System Requirements The files of the IRX software consist of IR image, visual image, all of which are far bigger than normal text files, thus the following standards of the computer hardware configuration should be met: CPU PENTIUM ®...
5.3 Thermal Imaging Camera Setting 1) Search: Click the search button. After a few seconds, the software will automatically search to the thermal imaging camera, and show the IP address. As shown in the figure 5-2. Figure 5-2 2) Remote operate: It can operate the thermal imaging camera multi-functionally, such as Remote setup, Modify IP, AVI preview, Gray preview, Capture image and Downloads file.
Page 17
Humidity: Set up the humidity in order to get more accurate result. It is recommended to keep the default humidity. Radiance: Set up the radiance in order to get more accurate result, according to the real transmission coefficient of filter, such as germanium wafer. In the menu of temp, users can add spots, line or areas, and select one of them as reference.
Page 18
Figure 5-5 AVI preview: It can capture the images of thermal imaging camera, record video, stop recording and set up the thermal image focal length. Click the Auto Focus button, then the device will adjust the focus automatically in order to get crisp thermal images.
Page 19
Gray preview: Preview and analysis the current target gray value of thermal images. As shown in the figure 5-7. Figure 5-7 Capture image: Capture the gray images, JPG images and BPM images. Download file: Download the images and videos which are saved in the device.
5.4 Function Area Operation Function area can analyze images and videos. It divides into 7 parts: Files, View, Analysis, Setup, Help, Report and PTZ control. As shown in the figure 5-8. Figure 5-8 1)File Open files or quit the software. Only gray images in Utd ...
Page 21
2)View Analyze the added dots, lines and rectangles, as well analyze temperature differences. As shown in the figure 5-10. Figure 5-10 Set up the measurement target, object name, alarm temperature, object type and object shape. As shown in the figure 5-11.
Page 22
point. As shown in the figure 5-13. Figure 5-13 3)Analysis Set up the view size: Full screen, Real size, 2X and 4X. As shown in the figure 5-14. Figure 5-14 4) Setup Basic setup Set up the temperature of the unit. ...
Page 23
More details please refer to the figure 5-15. Figure 5-15 Series setup Set up series, baud rate, data bit, check bit, stop bit, buffer size and waiting time. As shown in figure 5-16. Figure 5-16 5)Help Click the “help” to open the user manual, and click “about ...
Page 24
Figure 5-17 6)Report Select report template. Users can select the blank template or standard template to edit. Set up the appearance of the report, the title, the alignment, the border color and the background color. Set up the font of report, the font size, the bold, font color ...
Page 25
Click the button “PTZ Control”. In the interface, users can look over the visible light images and thermal images. In outdoors, GPS will locate to the latitude and longitude, and then display them in the thermal images. As shown in the picture 5-19.
and Auto. And users can save Avi, stop saving and adjust video quality. As shown in the picture 5-21. Picture 5-21 Click the “sync time” to adjust the time, and click the “Capture” to capture images manually. As shown in the picture 5-22.
Analyze the trend range of highest temperature when users play the videos. And it will analyze all frames. As shown in the figure 5-24. Figure 5-24 5.6 Histogram right menu bar, there option “ ”. Please check it. Then it will analyze the temperature distribution of each frame when users play the videos.
1) iso show: Check “ ” , and adjust the maximum or minimum temperature. 2) Palette: There are 12 kinds of palettes are available. As shown in the figure 5-26. Figure 5-26 5.8 Video Setup Related parameters can be set up related to video settings when users play videos.
7. Technical Support For common mistakes and issues during operation, please refer the following form. If the issue cannot be resolved, please contact our technical support department. Problems Possible Causes Reference Solutions Imaging not Not Adjust the lens Adjust the lens focus focus clear, temp measurement...
Need help?
Do you have a question about the IR-CAM-160-P4 and is the answer not in the manual?
Questions and answers