INSTALLATION AND SERVICE MANUAL
PURE LINK WATER SYSTEMS
DIMENSIONS
WIDTH
DEPTH
HEIGHT (with Boost Pump
and Transformer)
WEIGHT
Shipping (with Boost and
Delivery Pump, Transformer,
and two Modules)
Gross Operating (with Boost and
Delivery Pump, Transformer,
and two Modules)
ELECTRICAL REQUIREMENTS (Only when Booster Pump is included)
100V/50-60Hz
115V/60Hz
230V/50-60Hz
WATER REQUIREMENTS
Potable Water Supply
STORAGE CAPACITY
Storage Unit
One (1) Membrane Unit
Two (2) Membrane Unit
PRODUCTION RATE, WITH BOOST PUMP (@ 60psi, 77°F INLET)*
One (1) Membrane Unit
Two (2) Membrane Unit
*Gallons per Day
(Continued on inside cover page)
This Manual supersedes the Installation and Service Manual 28-0461/02, dated 04/23/03
Customer Service • Domestic / International – 800-729-1500
"Lancer" is the registered trademark of Lancer • Copyright — 2003 by Lancer, all rights reserved.
LANCER SERIES 1300
SPECIFICATIONS
18 3/4 Inches
4 5/8 Inches
29
Inches
33.60 pounds
60.60 pounds
1.2 Amps
0.8 Amps
0.4 Amps
4.00 Gallons
(15.14 Liters)
4.00 Gallons
(15.14 Liters)
4.00 Gallons
(15.14 Liters)
170.85 GPD*
(646.7 LPD)
269 GPD
(1018.3 LPD)
6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000
FAX SALES • USA -CANADA – 210-310-7250
Warranty / Technical Support - Field • 800-729-1500
Please refer to the Lancer web site (www.lancercorp.com) for
information relating to Lancer Installation and Service Manuals,
Instruction Sheets, Technical Bulletins, Service Bulletins, etc.
FOR
(47.63 cm)
(11.75 cm)
(73.66 cm)
(15.24 kg)
(24.79 kg)
System Tested and Certified by
NSF International against
NSF/ANSI 58 for the reduction of
Barium, Hexavalent Chromium,
Radium 226/228, TDS, and Cysts.
DATE:
06/17/03
P.N.
28–0461/03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pure Link 1300 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for lancer Pure Link 1300 Series

  • Page 1 FAX SALES • USA -CANADA – 210-310-7250 Warranty / Technical Support - Field • 800-729-1500 DATE: 06/17/03 Customer Service • Domestic / International – 800-729-1500 P.N. 28–0461/03 "Lancer" is the registered trademark of Lancer • Copyright — 2003 by Lancer, all rights reserved.
  • Page 2: Performance Data

    (Continued from cover page) WORKING PRESSURE Minimum 30 psi (206.8 KPa) Maximum 120 psi (827.4 KPa) Maximum inlet pressure 80 psi (551.6 KPa) (with boost pump) OPERATING TEMPERATURE Minimum 40°F (4.4°C) Maximum 113°F (45°C) FLOW RESTRICTOR RATIO (REJECT PRODUCT) One (1) Membrane Unit Two (2) Membrane Unit Efficiency rating, as verified by testing in accordance with NSF/ANSI 58: One Membrane...
  • Page 3: Table Of Contents

    LANCER PRE-FILTER KIT, TWIN-PAC, 5 MICRON (10” AND 20”) (OPTIONAL EQUIPMENT).......................13 LANCER PURE LINK DELIVERY PUMP KIT, PN 82-3202 (OPTIONAL EQUIPMENT)....13 LANCER PURE LINK DELIVERY PUMP, PN 86-0139 (OPTIONAL EQUIPMENT) .......14 LANCER PURE LINK DELIVERY PUMP, PN 86-0132 (OPTIONAL EQUIPMENT) .......14 TEST EQUIPMENT (AVAILABLE THROUGH LANCER CUSTOMER SERVICE).........15...
  • Page 4: Installation

    1" (Minimum) does not have a delivery pump, it should be mounted high enough on the wall to allow gravity feed to the point of use. NOTE: Lancer recommends installation height seven (7) feet (top of Drain Refer to Local unit) for gravity feed units.
  • Page 5: Filtering The Water Supply

    B. In the event the building is not equipped with these filters, then a suitable pre-filter and a carbon block filter must be installed and maintained at proper intervals. For selection of the proper filtration system, refer to your Lancer Catalog or contact Lancer Customer Service. CONNECTING UNIT TO DRAIN The module drain is located on the bottom left hand side of the unit, marked “DRAIN”.
  • Page 6: Connecting Unit To Water Supply

    G. Remove gauge and reconnect feed water line from Pure Link to boost pump outlet. H. Turn on water supply and connect unit to electrical supply. Check for pump operation and leaks. NOTE: Pressure Test Gauge is available through Lancer Customer Service.
  • Page 7: Sanitizing And Purging System Upon Installation

    NOTE: The cleaning and sanitizing procedures provided herein pertain to the Lancer equipment identified by this manual. If other equipment is being cleaned, follow the guidelines established by the manufacturer for that equipment.
  • Page 8: Installations

    Gravity feed or remote pump system from Product Out port at the bottom of the Pure Link unit. B. Coffee, Espresso, and Ice Tea Method Use remote delivery pump kit. (Refer to Lancer Catalog or contact Lancer Customer Service.) Pure Link Installation With Storage Unit...
  • Page 9: Cleaning And Maintenance

    The Reverse Osmosis System contains a replaceable treatment component critical for effective reduction of dissolved solids. The product water shall be tested periodically to verify that the system is performing properly. TDS Sampling Kits and/or meters are available through Lancer Customer Service. Pure Link Installation...
  • Page 10: Filter Replacement

    Periodic water quality testing of the Product Water is recommended every six (6) months at a minimum. When TDS reduction of system is less than 80% compared to untreated feed water, Lancer recommends replacement of the Membrane Module(s). Sanitizing procedures should be followed when necessary to reduce bacteria growth. See Section 1.12 of this Manual.
  • Page 11: Replacing The Storage Bag

    E. Proceed to Sanitizing Instructions, Section 1.12. PURE LINK STORAGE SYSTEM WITH 38.5 GALLON STORAGE BAG If unit installation is also equipped with 38.5 Gallon Storage Bag(s), refer to Lancer Installation and Service manual 28-0530/01, Pure Water Storage System, Lancer Series 1300.
  • Page 12: System Cannot Keep Up To Host Unit, Ice Maker, Coffee Maker, Etc

    TROUBLE CAUSE REMEDY 6.5 System cannot keep up A. Host machine has malfunction, A. Contact your authorized service to host unit, ice maker, or continuous leak. technician to fix the host coffee maker, etc. equipment. B. Pure Link production rate is B.
  • Page 13: Tube Connections

    With the collet held in this position, the tube can be removed. The fitting can then be re-used. NOTE: Lancer uses only genuine John Guest fittings in manufacturing the Pure Link system and associated components.
  • Page 14: Illustrations, Parts Listings, And Wiring Diagrams

    7. ILLUSTRATIONS, PARTS LISTINGS, AND WIRING DIAGRAMS LANCER PURE LINK, REVERSE OSMOSIS SYSTEM OPTIONAL ITEM WITH BOOST PUMP OPTIONAL ITEM DELIVERY PUMP FOR UNITS MANUFACTURED THROUGH 05/30/02 OPTIONAL ITEM WITH OPTIONAL BOOST OR DELIVERY 1 OR 2 MEMBRANE PUMP OPTIONAL ITEM...
  • Page 15 LANCER PURE LINK, REVERSE OSMOSIS SYSTEM (CONTINUED) ITEM PART NO. DESCRIPTION ITEM PART NO. DESCRIPTION 30-8164/01 Cover, Enclosure 05-1915 Clip, Retaining, Bag 08-0415 Tubing, LLDPE, JG, 3/8 04-0477 Screw, 8 - 32 x 0.375, PH 82-3402 Vent, Sub-Assy, Lancer Pure Link...
  • Page 16: Lancer Pre-Filter Kit, Twin-Pac, 5 Micron (10" And 20") (Optional Equipment)

    LANCER PRE-FILTER KIT, TWIN-PAC, 5 MICRON (10” AND 20”) (OPTIONAL EQUIPMENT) ITEM PART NO. DESCRIPTION 82-3021 10” Sump Kit, Twin-Pac, 5 Micron 82-3078 20” Sump Kit, Twin-Pac, 5 Micron 82-3074 10” Pre-filter Cartridge, 5 Micron 82-3081 20” Pre-filter Cartridge, 5 Micron 82-3075 10”...
  • Page 17: Lancer Pure Link Delivery Pump, Pn 86-0139 (Optional Equipment)

    LANCER PURE LINK DELIVERY PUMP, PN 86-0139 (OPTIONAL EQUIPMENT) ITEM PART NO. DESCRIPTION 86-0139 Pump, Delivery, 115V, Variable Speed, 1.2 GPM (Open Flow) 01-2393 Fitting, Quick Connect x1/2 Barb, 90 Degree Elbow (Standard Fitting) 01-2392 Fitting, Quick Connect x1/2 Barb,...
  • Page 18: Test Equipment (Available Through Lancer Customer Service)

    TEST EQUIPMENT (AVAILABLE THROUGH LANCER CUSTOMER SERVICE) TDS Meter, PN 82-3060 TDS Meter, PN 81-0581 10 PPM Resolution 1 PPM Resolution Water Quality Test Kit, PN 82-3328 pH Meter, PN 81-0582 Tests for pH, Alkalinity, Chlorine, and Hardness...
  • Page 19: Lancer Pure Link Water Units

    LANCER Pure Link Water Units An Explanation of LANCER's Pure Link Part Numbering System 4th Digit 1 = 100V, 50-60Hz Number of Membranes 2 = 115V, 60Hz (or Class) 1 , 2 or 3 3 = 230V, 50-60Hz 3rd Digit 5 = With Delivery Pump 1 = Generator (R.O.
  • Page 20: Certificate Of Warranty

    (5) years from date of original LANCER shipment from a facility or from an authorized Lancer Distributor. ® All other parts of the HSRS, one (1) year from date of original shipment from a LANCER facility or from an authorized Lancer Distributor.