USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE Manufactured by: UNIT FOR FUTURE REFERENCE. Industries Dettson inc HOMEOWNER: 3400 Industrial Boulevard Sherbrooke, Quebec - Canada PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE J1L 1V8 REFERENCE.
SAFETY REGULATIONS IMPORTANT: All local and national code requirements governing the installation of oil burning equipment, wiring and flue connection MUST be followed. Some of the codes SAFETY LABELING AND WARNING SIGNS that may apply are: The words DANGER, WARNING and CAUTION are used to CSA B139: Installation Code for oil burning identify the levels of seriousness of certain hazards.
INSIDE. DIA. Within 6' (1.82 m) (in Canada) of a window or door, or VENT PIPE VENT PIPE mechanical air supply inlet to any building;* VTK-53A & VTK1 7,62 cm (3") 6,10 m (20') ,91 m (3') VTK-64A & VTK2 10,16 cm (4")
Installing the terminal in the wall the proper evacuation from the inside to the outside; Open up a 6" (15,24 cm) hole for the VTK-53A / VTK1, Remove the 3 screws (item C) holding the end cone VTK-54A / VTK098 / KLAVT0101DET and VTK-64A / (item A) in place and remove the cone;...
Figure 3 : Installation of the terminal in the wall Figure 5 : Pressure switch location PRESSURE SWITCH DNS-1311 Rev B DNS-1094 Rev D 13. Reinstall the end cone (item A) and replace the three Install the stabiliser shroud (item B), as shown in Figure mounting screws;...
surrounded by insulation and covered with an outer tube of Figure 8 : Seams alignment 4” (10,16 cm), 5” (12,70 cm), or 6” (15,24 cm) flexible corrugated aluminium sleeve to protect the insulation. SEAM OF THE FLEXIBLE VENT Splicing vent lengths together prohibited.
Apply a high temperature silicone bead (item M) around 3” (7.6 cm) 90° elbow, female-female (for terminal); the outside of the terminal coupling (item K). Install the 3” (7.6 cm) female to 2" female reducer assembly consisting of the flexible vent (item I) and the (Riello 40-BF burner only);...
2.4.7 Intermediate piping A sealed combustion system can only be installed on approved furnaces. Refer to the nameplate on the furnace and Table 3 of this manual. Pipe as required between the terminal and the burner. Ensure that the 3” (7.6 cm) piping is routed and supported in COMBUSTION GAS TEMPERATURE accordance with local and national codes.