Dettson VTK1 Installation Instructions And Homeowner's Manual

Dettson VTK1 Installation Instructions And Homeowner's Manual

Sealed combustion system (direct vent)

Advertisement

Quick Links

SEALED COMBUSTION
INSTALLER / SERVICE TECHNICIAN:
USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND
SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE
UNIT FOR FUTURE REFERENCE.
HOMEOWNER:
PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE
REFERENCE.
Printed in Canada
Printed on 100% recycled paper
SYSTEM
(DIRECT VENT)
Models:
VTK1
VTK2
VTK098
VTK3
KLAVT0101DET
KLAVT0201DET
VTK-53A
VTK-54A
VTK-64A
VTK-65A
Caution: Do not tamper with
the unit or its controls. Call a
qualified service technician.
Manufactured by:
Industries Dettson inc
3400 Industrial Boulevard
Sherbrooke, Quebec - Canada
J1L 1V8
2015-12-04
.
X40142 Rev.J

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VTK1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dettson VTK1

  • Page 1 USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE Manufactured by: UNIT FOR FUTURE REFERENCE. Industries Dettson inc HOMEOWNER: 3400 Industrial Boulevard Sherbrooke, Quebec - Canada PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE J1L 1V8 REFERENCE.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS FIGURES Figure 1: Minimum clearance ..........4 SAFETY REGULATIONS ........3 Figure 2: Components identification ........5 SAFETY LABELING AND WARNING SIGNS3 Figure 3: Installation of the terminal in the wall ....6 IMPORTANT NOTICE........3 Figure 4: Installation of the stabiliser shroud ......6 Figure 5: Pressure switch location ........
  • Page 3: Safety Regulations

    SAFETY REGULATIONS IMPORTANT: All local and national code requirements governing the installation of oil burning equipment, wiring and flue connection MUST be followed. Some of the codes SAFETY LABELING AND WARNING SIGNS that may apply are: The words DANGER, WARNING and CAUTION are used to CSA B139: Installation Code for oil burning identify the levels of seriousness of certain hazards.
  • Page 4: Positioning

    INSIDE. DIA. Within 6' (1.82 m) (in Canada) of a window or door, or VENT PIPE VENT PIPE mechanical air supply inlet to any building;* VTK-53A & VTK1 7,62 cm (3") 6,10 m (20') ,91 m (3') VTK-64A & VTK2 10,16 cm (4")
  • Page 5: Installation Of The Components

    Installing the terminal in the wall the proper evacuation from the inside to the outside; Open up a 6" (15,24 cm) hole for the VTK-53A / VTK1, Remove the 3 screws (item C) holding the end cone VTK-54A / VTK098 / KLAVT0101DET and VTK-64A / (item A) in place and remove the cone;...
  • Page 6: Insulated Flexible Venting

    Figure 3 : Installation of the terminal in the wall Figure 5 : Pressure switch location PRESSURE SWITCH DNS-1311 Rev B DNS-1094 Rev D 13. Reinstall the end cone (item A) and replace the three Install the stabiliser shroud (item B), as shown in Figure mounting screws;...
  • Page 7: Connection To The Furnace Breech

    surrounded by insulation and covered with an outer tube of Figure 8 : Seams alignment 4” (10,16 cm), 5” (12,70 cm), or 6” (15,24 cm) flexible corrugated aluminium sleeve to protect the insulation. SEAM OF THE FLEXIBLE VENT Splicing vent lengths together prohibited.
  • Page 8: Connection Of The Air Intake Pipe

    Apply a high temperature silicone bead (item M) around 3” (7.6 cm) 90° elbow, female-female (for terminal); the outside of the terminal coupling (item K). Install the 3” (7.6 cm) female to 2" female reducer assembly consisting of the flexible vent (item I) and the (Riello 40-BF burner only);...
  • Page 9: Intermediate Piping

    2.4.7 Intermediate piping A sealed combustion system can only be installed on approved furnaces. Refer to the nameplate on the furnace and Table 3 of this manual. Pipe as required between the terminal and the burner. Ensure that the 3” (7.6 cm) piping is routed and supported in COMBUSTION GAS TEMPERATURE accordance with local and national codes.
  • Page 10: Table 3: Approved Furnaces For Used With Vtk / Ifv

    IFV-410A / IFV-415A / IFV-420A AMT112 NX-56LQ R40-BF5 VTK-54A IFV-410A / IFV-415A / IFV-420A AMT154 NX-50LC R40-BF5 VTK-65A IFV-510A / IFV-515A / IFV-520A HMT (Dettson) R40-BF5 VTK-65A IFV-510A / IFV-515A / IFV-520A HMT (ICP) R40-BF5 VTK3 IFV508 / IFV520 NOLF105 (Dettson) AFII-85 R40-BF3...
  • Page 11: Figure 12: Dimensions

    Figure 12 : Dimensions Figure 13 : Wiring Diagram...
  • Page 12: Figure 14: Parts List

    Figure 14 : Parts List Table 4 : Parts List Part No VTK-54A VTK-65A ITEM DESCRIPTION VTK-53A VTK-64A VTK098 VTK3 VTK1 VTK2 KLAVT0101DET KLAVT0201DET End Cone 4DETECK1 4DETECK1 4DETECK1 4DETECK1 Stabiliser Shroud 4DETTEK1 4DETTEK2 4DETTEK2 4DETTEK3 Screw Philips 8-32 x 1/2" SS...