Download Print this page

Leader Light PRO WASH VARIO OPTIC Series User Manual page 2

Advertisement

03.5 dMX channels - subject to change
-
The latest version of DMX channels appendix are on the websites - www. leaderlight.eu
Ch.
WASH 600 RGBAW
Ch.
1
Red 1,2,3
1
Amber 1,2,3
2
Green 1,2,3
2
White 1,2,3
3
Blue 1,2,3
3
Master (Dip1=On, Dip4=Off)
4
Amber 1,2,3
4
Strobo (Dip1=On, Dip4=Off)
5
White 1,2,3
5
6
Master (Dip1=On, Dip4=Off)
6
7
Strobo (Dip1=On, Dip4=Off)
7
1
Red 1
1
Amber 1
2
Green 1
2
White 1
3
Blue 1
3
Amber 2
4
Amber 1
4
White 2
5
White 1
5
Amber 3
6
Red 2
6
White 3
7
Green 2
7
Master (Dip1=On, Dip4=Off)
8
Blue 2
8
Strobo (Dip1=On, Dip4=Off)
9
Amber 2
9
10
White 2
10
11
Red 3
11
12
Green 3
12
13
Blue 3
13
14
Amber 3
14
15
White 3
15
16
Master (Dip1=On, Dip4=Off)
16
17
Strobo (Dip1=On, Dip4=Off)
17
Dip4=Off, Dip1=Off =>DipBCD: use rotating switch for DMX start address (RS1-100, RS2-010, RS3-001) from 001 to 511
Dip4=Off, Dip1=On:
address+2channel (Master+Strobo)
Dip4=On, Dip1=Off:
switch on AutoRun-table functions: "100"=Prg.0-9, "10"=StepTime, "1"=FadeTime
Dip4=On, Dip1=On:
switch all channels on 50% - test function
Dip2=Off: Mode 1 (5+2ch)
Dip2=Off: Mode 1 (2+2ch)
Dip2=On: Mode 4 (15+2ch)
Dip2=On: Mode 4 (6+2ch)
Dip3=Off:
standard curve
Dip3=On:
ultraSoft curve
For one luminary LL PRO WASH 1200 is necessary to order 3pieces
LL VARIO OPTIC 400 WASH1200
WASH 600 AW
Ch.
WASH 1200 RGBAW
Mode1: dip2=Off
1
Red 1,2,3,4,5,6
2
Green 1,2,3,4,5,6
3
Blue 1,2,3,4,5,6
4
Amber 1,2,3,4,5,6
5
White 1,2,3,4,5,6
6
Master (Dip1=On,Dip4=Off)
7
Strobo (Dip1=On,Dip4=Off)
Mode4: dip2=On
1
Red 1
16
2
Green 1
17
3
Blue 1
18
4
Amber 1
19
5
White 1
20
6
Red 2
21
7
Green 2
22
8
Blue 2
23
9
Amber 2
24
10
White 2
25
11
Red 3
26
12
Green 3
27
13
Blue 3
28
14
Amber 3
29
15
White 3
30
31
32
Extention and control functions:
Dip2=Off: Mode 1 (5+2ch)
Dip2=On: Mode 4 (30+2ch)
180°
x
x
AIMING POSSIBILITy
The fixture could be aim to wish
position with bracket.
Ch.
WASH 1200 AW
1
Amber 1,2,3,4,5,6
2
White 1,2,3,4,5,6
3
Master (Dip1=On,Dip4=Off)
4
Strobo (Dip1=On,Dip4=Off)
5
6
7
Red 4
1
Amber 1
Green 4
2
White 1
Blue 4
3
Amber 2
Amber 4
4
White 2
White 4
5
Amber 3
Red 5
6
White 3
Green 5
7
Amber 4
Blue 5
8
White 4
Amber 5
9
Amber 5
White 5
10
White 5
Red 6
11
Amber 6
Green 6
12
White 6
Blue 6
13
Master (Dip1=On, Dip4=Off)
Amber 6
14
Strobo (Dip1=On, Dip4=Off)
White 6
15
Master (Dip1=On, Dip4=Off)
16
Strobo (Dip1=On, Dip4=Off)
17
Dip2=Off: Mode 1 (2+2ch)
Dip2=On: Mode 4 (12+2ch)
VARIO OPTIC INSTALLATION
The optic installation is easy and fast by 2 screws.
x
x
04 PERNAMENT USE LIMITATIONS fOR HEATING dISSIPATION
-
Pernament use limitations for heating dissipation of LL PRO WASH RGBAW
body temperature must be less then 55°C
40°C ambient temperature -20% of total power
30°C ambient temperature -10% of total power
20°C ambient temperature -0% of total power
Black version - 30%
Silver or White version - 50%
Example: Then final pernament value for BLACK colour and 40°C ambient
temperature = -30% -20% = 56% = max 143 ≥ (R + G + B + W +A) / 5
It's mean average of power go inside the fixture at DMX signal
Example:
black LL PRO WASH: 180 ≥ (R + G + B + W + A) / 5
Silver or White LL PRO WASH: 128 ≥ (R + G + B + W +A) / 5
Value for R or G or B or W or A is 100% = 256 = 8bit levels *** REd 50% = 128
value, REd 75% = 192 value
final information we don't drop down each colour power with temperature
control to get maximum for each colour under total recomMendations , therefore
you need setup limitations from control desk !!!
INSTALLATION
Ventilation space 180° free
minimal.
80mm
x
x
x
x
minimal.
80mm
Minimal mounting distance from surface
x
x
!
!
x
x
x
x
x
x
+
+
+
+
+
+
+
+
+
+
+
+
Ventilating slots
05 MAINTENANCE
-
To tackle all Safety Information- 01!
-
Damage caused by inadequate cleaning or maintenance is not coverd by warranty.
-
Regular cleaning is demand (dust, dirt, ...)
Maintenance policy:
-
Unplug mains before maintenance and at least 10 minutes cool off
-
Appliance do not illegal open or demount
-
Clean-up dust only from outer surface (for ex. scuttle, diffuser and lenses).
-
Use vacuum or dumpy duster (warm water)
1.2
-
Before reinstalling to check failure-free state – no wet parts!
If you have any question please, contact support@leaderlight.sk
Ventilation space 90° free
minimal.
100mm
x
x
x
x
minimal.
80mm
1.1
WARNING!!!
Non-minimum distance and /or non-use
the original brackets is at your own risk!
+
+
+
+
+
+
+
+
+
+
+
+

Advertisement

loading

This manual is also suitable for:

Pro wash vario optic 600 rgbawPro wash vario optic 600 awPro wash vario optic 1200 rgbawPro wash vario optic 1200 awLl37 104Ll37 105 ... Show all