Page 1
Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notifi cation.
Page 2
♦ Retaining Ring Other brand and product names are trademarks or registered trademarks of their respective holders. ® Barnes is a registered trademark of Crane Pumps & Systems, Inc 1999, 2002, 11/03, 6/05, 4/06 , 9/06, 2/07 Alteration Rights Reserved...
Page 3
WARNING! - DO NOT pump hazardous materials IMPORTANT! - Crane Pumps & Systems, Inc. is not (fl ammable, caustic, etc.) unless the pump is specifi cally responsible for losses, injury, or death resulting from a designed and designated to handle them.
Page 4
SECTION: SERVICE AND REPAIR 10 PSI è 1) Lubrication: Anytime the pump is removed from operation, the cooling oil in the motor housing should be checked visually for oil level and REMOVE HANDLE contamination. PRESSURE GAUGE ASSEMBLY 1.1) Checking Oil: Motor Housing - To check oil, set unit upright.
Page 5
2) Impeller and Volute Service: 3.2) Reassembly: 2.1) Disassembly and Inspection: Bearing - When replacing bearing, be careful not to damage the rotor or shaft threads. Clean the shaft thoroughly. Insert To clean out volute, disconnect power, remove hex nuts, retaining ring onto motor shaft.
Page 6
3.4) Conduit Box Design: 4) Shaft Seal and Diaphragm Service: Refi ll with cooling oil as outlined in paragraph 1.4. Position conduit box and square ring over opening. Place lockwashers Important ! - Handle seal parts with extreme care. on cap screws, apply Loctite to cap screws threads and torque DO NOT scratch or mar lapped surfaces.
Page 7
remove probe from bearing bracket. Pipe plugs replace sensor SENSOR CORD probes when pump is supplied without moisture sensors. Seal - To expose shaft seal for examination, complete above procedure and slide off outboard rotating member (See Figure 6). Remove inboard rotating member, from shaft. Examine all seal parts and especially contact faces.
Page 8
FIGURE 6 FIGURE 7 Seal - Clean and oil seal cavities in bearing bracket and seal Motor & Seal Plate Rotating Member plate. Lightly oil (DO NOT use grease) outer surface of inboard Stationary stationary member and outboard stationary member. Press inboard stationary member fi...
Page 9
Limited 24 Month Warranty Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship under normal use and service for twenty-four (24) months after manufacture date, when installed and maintained in accordance with our instructions.This warranty gives you specifi c legal rights, and there may also be other rights which vary from state to state.
Page 10
Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.