Uniblitz VincentAssociates VED24 Instructions Manual

Shutter driver

Advertisement

Quick Links

1.800.828.6972
User Manual
VED24 Shutter Driver
14-0071
Version 1.40
2020

Advertisement

Table of Contents
loading

Summary of Contents for Uniblitz VincentAssociates VED24

  • Page 1 1.800.828.6972 User Manual VED24 Shutter Driver 14-0071 Version 1.40 2020...
  • Page 2 For information regarding applicable intellectual property, please visit www.uniblitz.com/patents. Information in this publication supersedes that in all previously published material. Due to our ongoing development program, Vincent Associates reserves the right to discontinue or change specifications or designs, at any time, without incurring any obligation.
  • Page 3: Warranty

    Warranty LIMITED PRODUCT WARRANTY: All Products manufactured by VINCENT ASSOCIATES® (MANUFACTURER) are warranted to meet published specifications and to be free of defects in materials and workmanship as defined in the specifications for 365 days - one year - (WARRANTY PERIOD) from the date of original shipment of the product. DSS series shutters are additionally warranted as defined in the DSS SERIES CYCLE WARRANTY CRITERION below.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS WARRANTY........................2   LIST OF TABLES ......................4   LIST OF FIGURES ......................4   GENERAL SAFETY SUMMARY .................. 5   Injury Precautions ..................... 5   Product Damage Precautions ................... 6   Safety Terms and Symbols ..................7   PREFACE ..........................
  • Page 5: List Of Tables

    List of Tables Table 1: 5-Pin SwitchCraft Male Receptacle Pin-Out ............18   Table 2: FUNCTION DIP Switch Settings ................20   Table 3: VED24 Octal Switch Pulse Duration Settings ............20   Table 4: Function & Octal Switch Settings for All Available Shutter Series ....... 21  ...
  • Page 6: General Safety Summary

    General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use the product only as specified. Only qualified personnel should perform service procedures. Injury Precautions  Use Proper Supply Power and Proper Power Cord (Included) – To avoid fire hazard, use only correct power and cable as specified elsewhere in this manual.
  • Page 7: Product Damage Precautions

    Product Damage Precautions  Use Proper Power Source – Do not operate this product from a power source that applies more than the voltage specified. It is recommended to use the PS24 (included) or equivalent DC Power Supply.  Provide Proper Ventilation – To prevent product overheating, provide proper ventilation.
  • Page 8: Safety Terms And Symbols

    Safety Terms and Symbols These terms appear in this manual Warning statements identify conditions or practices that WARNING could result in injury or loss of life. Caution statements identify conditions or practices that CAUTION could result in damage to this product or other property. VED24 User Manual...
  • Page 9: Preface

    USB interface.  Index contains a full index.  What follows is the complete operator’s manual for the UNIBLITZ VED24 Shutter Driver. Please read this manual completely before operating the unit. Due to the construction of this unit, Vincent Associates recommends that the unit be returned to the manufacturer for repair.
  • Page 10: Getting Started

     Operates all shutters in a bi-stable or uni-stable configuration – user configurable via FUNCTION switches.  5-pin Male SwitchCraft locking shutter interface connector.  Operates most UNIBLITZ ® shutters such as CS, DSS, NS, LS, TS and VS series. (See Table #4 on page 21 for additional exclusions.) The 510F interconnect cable (included)
  • Page 11: Power Supply, Cables, And Misc

    Power Supply, Cables, and Misc  PS24 +24 VDC, 40W Power Supply,100 – 240 VAC, 50/60 Hz (Included)  510F Shutter interconnect cable, 5-pin female SWC to 5-pin female SWC, 3 meters. (Included)  5M203D Shutter Adapter Cable, 5-pin male Switchcraft to 2-pin JST adapter for DSS & TS shutter series.
  • Page 12: Introduction

    FUNCTION switches is accessible on the front panel. These switches will set the VED24 in a number of configurations to allow most UNIBLITZ shutter types to be driven. The rotary octal switch establishes 16 different PULSE DURATION selections for each uni-stable and bi-stable shutter selections for a total of 32 timing pulse selections.
  • Page 13: Start Up

    Start Up After unpacking your unit inspect for any defects. If upon inspection a problem is found, or a part (or parts) is missing, notify Vincent Associates immediately. A check list is provided for a quick inventory of included cables and accessories. After the initial inspection the unit is ready to use.
  • Page 14: Initial Operation And Testing

    FUNCTION switches are configured for the proper shutter used; uni- stable or bi-stable. Please see FUNCTION Select under GENERAL CHARACTERISTICS. ® The VED24, UNIBLITZ driver provides the circuitry necessary to support shutters equipped with the solid state synchronization option. Simply plug the shutter-interconnect cable into the driver.
  • Page 15: Figure 1, Ved24 Overall Dimensional Layout

    properly when the proper pulse width is presented to the PULSE INPUT, please notify Vincent Associates immediately. See Figure #1 for the VED24 driver’s overall dimensional layout. See Figure #2 for the 24VDC Power Supply overall dimensional layout. Figure 1, VED24 Overall Dimensional Layout VED24 User Manual...
  • Page 16: Figure 2, Ps24, 24Vdc Power Supply Overall Dimensional Layout

    Figure 2, PS24, 24VDC Power Supply Overall Dimensional Layout VED24 User Manual...
  • Page 17: Operator Controls

    Operator Controls VED24 Front Operator Controls Please Refer to Figure 3. 1. POWER LED indicator. A green LED indicating that DC power is being provided to the unit. 2. DRIVER LED indicator. A green LED indicating when the internal shutter driver circuit input has an active signal present.
  • Page 18: Figure 3, Ved24 Front Panel Layout

    Figure 3, VED24 Front Panel Layout VED24 User Manual...
  • Page 19: Ved24 Rear Operator Controls

    VED24 Rear Operator Controls Please Refer to Figure 4: 1. USB Serial Control Port Provides access to the VED24 COM PORT (USB) interface allowing the user to control functions via commands sent from a computer serial USB port. The INPUT jack accepts commands directly from a computer’s USB port. This is a listen only device and the status of the SYNC is not available at this time.
  • Page 20: Figure 4, Ved24 Rear Panel Layout

    Figure 4, VED24 Rear Panel Layout VED24 User Manual...
  • Page 21: Ved24 Function Operator Controls

    VED24 Function Operator Controls Please see the tables below for recommended Function & Octal switch settings to provide device status and timing values for all available shutter series. FUNCTION SWITCHES              1  LOCAL / REMOTE  LOCAL = UP  REMOTE = DOWN  2  VOLTAGE SELECT  +10.7VDC = UP  +18VDC = DOWN  3  BISTABLE / UNISTABLE  BISTABLE = UP ...
  • Page 22: Table 4: Function & Octal Switch Settings For All Available Shutter Series

      VED24 Drive Controller Settings Chart             FUNCTION     (Local ‐ Up  (+10V ‐Up  (Bi‐stable – Up   (Set 1 ‐ Up   SHUTTER  PULSE  ADAPTER           Remote ‐ Down) +18 ‐ Down)   Uni‐stable – Down)  Set 2 ‐Down) SERIES     1  2  3  4  DURATION  REQUIRED     5M203D  TS2B     X  UP  UP  UP  0  5M203D ...
  • Page 23: Notes

    Notes VED24 User Manual...
  • Page 24: Operating Basics

    Operating Basics Refer to the section describing the Initial Operation and Testing for initial preparation to put the VED24 into operation. Function Switches There are four piano-DIP slide switches located on the unit’s front panel. For specific functions see FUNCTION Select under GENERAL CHARACTERISTICS or Table The switch actuators can be moved to the up or down position with a small non metallic tool.
  • Page 25: I/O Considerations

    I/O Considerations The PULSE INPUT BNC is an Active Low input. When a signal transitions from the high state to the low state, the shutter driver will be initiated and the shutter will transition. Because this is an Active Low input, the controller can be triggered from a remote activate cable such as the optional 710R or the 710R/F.
  • Page 26: Trigger Cautions And Trouble Shooting Tips

    Trigger Cautions and Trouble Shooting Tips 1. The VED24 system's capability is greatly enhanced by external control as described previously, however, extreme care must be taken to ensure that high voltages (see SPECIFICATIONS) are not inadvertently switched into external control inputs. Also, note that large negative voltages can cause irreparable damage to the unit's internal circuitry. Exercise extreme caution.
  • Page 27: Maintenance

    Maintenance Proper care and maintenance of the unit should be taken as with any electronic instrument. With the exception of the external DC power supply, there are no user-serviceable parts in the VED24. There is no service to be performed by the user other than inspection for visible damage. Although the stability of the timing and drive voltage is assured and calibrated prior to shipment, it may become necessary to make some minor adjustments and upgrades to the firmware of the VED24 over time.
  • Page 28: Specifications

    Specifications System Characteristics Name Description  Minimum time between exposures is determined by Repeat Exposure shutter used and open / close pulse duration. Shutter Drive  Continuously variable frequency of exposures from DC to the shutter's maximum rate  Maximum peak pulse power: 41 W ...
  • Page 29: External Input Characteristics

    External Input Characteristics Name Description  Active-low PULSE INPUT (BNC)  Input impedance: 1K Ohms Front Panel  Maximum source current: 100 µA  Maximum sink current: 1µA  Minimum pulse width determined by applicable shutter  Maximum pulse width unlimited  TTL compatible: - Minimum high-level: +2.0 VDC - Maximum low-level +0.8 VDC ...
  • Page 30: General Characteristics

    General Characteristics Name Description POWER Indicator  Green 3mm LED indicates when DC power is present. Front Side DRIVER Indicator  Green 3mm LED indicates when the shutter driver circuit Front Side is active.  This LED will illuminate with or without the load of a shutter's actuator coil.
  • Page 31 General Characteristics (cont’d) Name Description PULSE DURATION Select 8-position octal switch allows selection of a number of (Octal Rotary Switch) different open / close pulse durations in units of msec.  Two sets of timing pulses are available depending on the Front Panel setting of the Bi-Stable / Uni-stable Function switch.
  • Page 32: Appendix A (Declaration Of Conformity)

    Description of Equipment: The following product is manufactured in the United States of America by Vincent Associates: Uniblitz VED24 Single-Channel Optical Shutter Controller EU Declaration of Conformity (EMC): Vincent Associates hereby declares that under its sole responsibility, and based on tests performed by G&M Compliance Inc., that the aforementioned product meets the requirements of the EU EMC Directive...
  • Page 33 EU Declaration of Conformity (LVD): Vincent Associates hereby declares that under its sole responsibility, and based on tests performed by G&M Compliance Inc., that the aforementioned product meets the requirements of the EU Low Voltage Directive 2014/35/EU by means of conformity to the following harmonized standard: IEC/EN 61010-1:2010 –...
  • Page 34: Index

    Index       +24 VDC, 13         24VDC Power Supply Overall Dimension Layout, 15  LIMIT OF LIABILITY, 2        510F, 9, 10, 13, 18, 30  Maintenance, 26  5M203D, 10, 30        N.O./N.C. Toggle switch, 16  701A‐S5, 10, 30  Notes, 22  710R, 10, 11, 24, 31        Octal Switch Pulse Duration Settings, 21  Octal Switch Setting, 30  Applicable Certifications (CE), 31     ON/OFF Power Switch, 19  Bi-Stable Timing Range, 30  Operating Basics, 23  Operating Temperature, 30     Cleaning Procedure, 26  Operator Controls, 16     OPERATOR CONTROLS, 13  Optional Accessories, 31 ...
  • Page 35 USB Input, 28  System Characteristics, 27     USB Operation, 24  terminal emulation program, 24  USB Serial Control Port, 18    USB‐AB, 10, 30  USB-Serial UART, 28  Trigger Cautions and Trouble Shooting Tips, 25        Uni-Stable Timing Range, 30  Warranty, 2  Weight, 30  USB driver program, 24  VED24 User Manual...