Convert transducer
from dual to single transmission-line
Patent http://www.airmar.com/patent.html
Follow the precautions below for optimal
product performance and to reduce the risk of
property damage, personal injury, and/or death.
WARNING: Always wear safety glasses, a dust mask,
and ear protection when installing.
CAUTION: To reduce electrical interference from
other electrical wiring and any on-board equipment with
strong magnetic fields such as radar equipment, radio
transmitters, boat engines, generators, etc., separate
the cables by at least 1m (3').
CAUTION: Be careful not to tear the cable jackets
when passing them through bulkheads and other
parts of the boat. Use grommets to prevent chaffing.
Use deck glands to prevent water seepage into the
boat.
IMPORTANT: Please read the instructions completely
before proceeding with the installation. These
instructions supersede any other instructions in your
instrument manual if they differ.
Tools & Materials
Safety glasses
Dust mask
Ear protection
Pencil
Electric drill
Drill bit
3mm or 1/8"
Grommets (some installations)
Deck gland (some installations)
Phillips screwdrivers
Heat-shrink tubing
Adjustable wrench
Petroleum jelly (such as Vaseline
Cable ties
INSTALLATION INSTRUCTIONS
External Diplexer
®
brand)
Where to Purchase Parts
Gemeco
Airmar EMEA
Applications
• Converts a dual transmission-line transducer to a single
transmission-line.
• For use with 1kW echosounders only
Installation
Mounting Location & Hole Drilling
1. Select a convenient, dry, mounting location for the water-
resistant Diplexer, a minimum of 1m (3') from other cables and
electronic equipment.
2. Hold the Diplexer at the selected location and mark the position
of the four screw holes.
NOTE: If the Diplexer will be mounted on a vertical surface,
face the cordgrip downward to avoid any possibility of water
seeping into the box.
3. At the marked locations, drill 3mm or 1/8" holes to a depth of
10mm (3/8"). Do not fasten the Diplexer in place at this time.
Cable Routing
1. Route the transducer cable from the transducer to the Diplexer.
Do not connect the transducer cable or fasten it in place at this
time.
2. Route the fishfinder cable from the fishfinder to the Diplexer's
cable. Do not connect the cables or fasten them in place at this
time.