Product Advantages; Important Notes - Denison Hydraulics 9-UK-22071-C Manual

Multi-function proportional valve dual driver ( encapsulated )
Table of Contents

Advertisement

Multi-Function Proportional Valve Dual Driver ( Encapsulated )

Product Advantages:

Important Notes:

Fully EMC compliant product status to EN50081-1 and EN50082-2 ( heavy industrial spec. )
2 x dual proportional protected MosFet driver outputs ( PWM ) at upto 3 amps ( @12V ) each.
Unit comprises of field and time tested and proved electronic circuit design.
No extra DIN housing or 'Card Holder' to buy.
High level of product integrity maintained under extreme operational environments.
Remote 'Enable' OR 'Emergency Stop' input for maximum system safety.
Fully 'Isolated' product design for improved safety and ease of application difficult areas.
Internally generated +/- voltages for immediate connection to external/ remote 10K joystick or pot.
Unrivaled Industry leading 'Linear' Input / Output electrical characteristic for this type of unit.
Unique, Small compact size, light weight unit with 'Blend-Anywhere' colour.
Front panel full unit status 'Diagnostic' LED display
Able to drive many different proportional products with ONE unit giving reduced inventory.
Very Low cost compared to DIN cards and other available modules with comparative functions.
Easy to use front panel adjustments for all major parameters.
'Digital' & visual signal output of 'mA Loop Failure' for indication and remote system shutdown.
Separate Linear characteristic Ramp 'UP' and Ramp 'Down' adjustments.
Separate 'I Min' and 'I Max' adjustments for each solenoid.
'Ruggedised' internal & external design allowing use on 'Internal' OR 'External' applications.
Heavy duty 'Two-Part' polarised screw terminal connectors for easy application and use.
User configurable ( by Links ) for 12V or 24V supply input.
User choice of command input signal ( by Links ) from 0 to +/-5V, 0 to +/-10V or o to +/-20mA.
User definable ( by Links ) 'Dither' frequency ( 100Hz, 140Hz & 250 Hz )
'Bulkhead', wall or panel mounting, rust proof, high impact absorbing ABS molded enclosure.
Easy and secure mounting via 3 x 5mm fixings.
Flame proof resin encapsulation.
Protected inputs and user outputs for maximum reliability and product life.
Range of 'Add-On' option sub-boards to enhance base characteristics.
Take a few minutes to FULLY read THESE information / data sheets BEFORE starting.
Make sure the unit supply voltage is the same as the coils on the valve being driven !
Ensure that you are aware of the available adjustments on the electronics and hydraulics.
Make sure you have the correct tools to do the intended job ( i.e. D.V.M. ) e.t.c.
'Isolate' this unit from all other equipment BEFORE any form of welding takes place.
Check ALL connections to and from this unit to ensure NO short circuits.
'Start' operating a new system at LOW pressure and with SMALL command signals.
Check the units supply voltage is CORRECT, ' ELECTRICALLY CLEAN ' and STABLE.
Operate the units within specified operating temperature for best & reliable performance.
Ensure that any unused wires / terminals are terminated safely and not shorted together.
Contact DENISON Hydraulics for more information if you are unsure of connecting this unit.
Fit the supplied rubber gasket correctly between valve coil and plug top driver unit.
Keep High Voltage AC cables separate from Low Voltage DC signal and supply cables.
Follow the set-up procedures in this manual for best operational results.
Arc Weld or Charge Batteries with this driver unit connected as damage can occur.
Attempt to use this unit if you are unsure of connections or expected operation.
Attempt to use this unit in Areas where AC or DC coils HAVE NOT been fully suppressed.
Use a power supply that is not rated for the correct required O/P current under full load.
Allow wires TO or FROM the unit to short circuit ( to each other or chassis/cabinet e.t.c. ).
Attempt to use this unit in areas of intense RF without adequate screening measures.
Disconnect or connect wires to or from this unit unless it it isolated from the power supply.
Use this unit in temperatures that exceed those specified as operation may be effected.
ALWAYS
NEVER
3