INSTRUCTIONS
Noaton AC 5109
Local air conditioner

Advertisement

Table of Contents
loading

Summary of Contents for Noaton AC 5109

  • Page 1 INSTRUCTIONS Noaton AC 5109 Local air conditioner...
  • Page 2 Read these instructions Before any kind of use, please read the relevant section of this owner’s manual At the end of its service life, this product may not be disposed of with other household waste, but must be taken to a collection point designated for recycling electrical appliances.
  • Page 3: Table Of Contents

    Contents Safety instructions ........................... 4 Notes related to R290 refrigerant ......................5 General principles............................ 6 Cooling principles of the air conditioner ....................6 Technical specifications ........................... 6 Product description ..........................7 Control panel ............................8 Power on/off button (POWER) ......................8 Mode change button (MODE) ......................
  • Page 4: Safety Instructions

    Safety instructions WARNING This portable air conditioner may not be used in areas in which the following conditions apply: - Potentially explosive places - Aggressive environments and rooms with open flame or other heat sources or electrical discharges - Areas containing high concentrations of solvents - Places with extremely high levels of dust Protect against children: To prevent possible injury, do not allow children to play with this appliance or around it.
  • Page 5: Notes Related To R290 Refrigerant

    Notes related to R290 refrigerant This equipment is only designed for use with R290 (propane) refrigerant, which is sealed in the refrigerant circuit under pressure. Repairs to this equipment may only be carried out by a specially trained service technician in accordance with national legislation on flammable substances! Do not manipulate with the cooling circuit, puncture it, or expose it to higher temperatures.
  • Page 6: General Principles

    This procedure is especially suitable with e.g. bedrooms, which should be cooled in advance before going to bed in order to avoid having to keep the air conditioner running overnight. Technical specifications Model Noaton AC 5109 Power source AC 220-240 V/1 Ph/50 Hz Air flow 330 m Dehumidifying capacity (30 °C, 80% RV)
  • Page 7: Product Description

    Product description Front Control panel Remote control signal receptor outflow Rear Handle Air suction Connecting the air hose Cable storage Drain with plug...
  • Page 8: Control Panel

    Control panel Power on/off button (POWER) Once connected to the mains power supply, the air conditioner will enter standby mode, the display will flash for a time and emit an audio signal. Press the on/off button (POWER) and the unit will switch to the initial "Smart"...
  • Page 9: Fan Speed Button (Speed)

    Fan speed button (SPEED) By pressing this button you switch between low (LOW) and high (HIGH) fan speeds. At the same time, a diode will light up on the control panel beside the relevant speed. This option to change speeds is switched off in the dehumidification (DEHUM) and sleep (SLEEP) modes.
  • Page 10: Overview Of Modes

    Inserting battery (battery is included in the pack) When you first use the device it is necessary to remove the protective plastic cover from the battery. Overview of modes Cooling mode (COOL) When room temperature is higher than the required temperature, the compressor will run and the air will be cooled.
  • Page 11: Package Contents

    Package contents 1 Hose 4 Remote control Outflow hose 2 Hose adapter 3 Hose end-piece Connecting the air hose and the adapter...
  • Page 12: Increase The Efficiency Of Mobile Air Conditioning

    Increase the efficiency of mobile air conditioning If you have classic tilt & turn windows (Eurowindows) we recommend to use a textile seal Noaton AL 4010 in order to seal a gap between a frame and a gasket once the air hose is installed.
  • Page 13: Error Messages On The Display

    Error messages on the display E0, E1 F YOU SEE THE ERROR MESSAGES ON THE DISPLAY PLEASE CONTACT YOUR LOCAL DISTRIBUTOR Error message on Meaning Problem-solving procedure the display Release water from the appliance using the outflow Internal water tank is full hose.
  • Page 14: Troubleshooting

    Troubleshooting BEFORE CONTACTING TECHNICAL SUPPORT PLEASE CHECK THE FOLLOWING TABLE PROBLEM POSSIBLE CAUSE SOLUTION Appliance has no power supply Plug the appliance into the mains. Appliance does not start Appliance is not switched on Press the on/off button (POWER). Power on/off button does If the problem cannot be solved, Follow the instructions above.
  • Page 15: Product Fiche

    Product fiche MANUFACTURER Gavri s.r.o. | Masná 27/9 | Brno | 60200 | CZ MODEL Local air conditioner Noaton AC 5109 DIMENSIONS 320 x 320 x 740 mm TYPE OF AIR CONDITIONER Single duct, cooling mode only INNER SOUND PRESSURE LEVEL IN dB(A)