  • Page 1 PROVISIONAL User’s and operator’s manual for art. 0305...
  • Page 2: Table Of Contents

    Safety informations ........................... page 2 Technical features..........................page 3 Before using............................page 4 Lamp installation, replacement and setting ..................page 5 Beam angle setting ........................... page 6 Control panel ............................ page 8 Control panel configuration and fixture management ..............page 9...
  • Page 3: Safety Informations

    The Hercules800e comes in unique version: • Art. 0305 HERCULES 800E The Hercules800e can work in automatic mode or in synchro mode, otherwise may be controlled by 8 bit DMX controllers The input protocol is the DMX 512. To drive the Hercules800e we suggest to use either our controller Control Show 512, Fancy or the Easy Control.
  • Page 4: Technical Features

    WARNING Check that the fixture has not been damaged during transport. If it has been damaged or it does not work, address the seller. Whether the fixture has been shipped to you directly, please contact the shipping company. Only the consignee (person or company) can claim for these damages. TECHNICAL FEATURES •LAMPS Lamps...
  • Page 5: Before Using

    CIRCUIT - BREAKER CONDUCTOR SIZES (length < 20mt.) MAINS VOLTAGE MAINS VOLTAGE CROSS SELECTIONAL AREAS 230V 0,03A 230V 3X1,5 mm (minimum) 110V 3x2,5 mm (minimum) pict.1 pict.2 3 PIN CONNECTOR FOR DMX LINE INPUT CONNECTOR IP 68 NEUTRAL LIVE EARTH BEFORE USING WARNING The equipment must be earthed.
  • Page 6: Lamp Installation, Replacement And Setting

    LAMP'S INSTALLATION/REPLACEMENT WARNING In case of replacement of the lamp or maintenance, do not open the fixture unless 10 minutes have passed from the switching off. This operation has to be done when the fixture is disconnected from the mains supply pict.3 pict.4 pict.5...
  • Page 7: Beam Angle Setting

    BEAM ANGLE SETTING (default 45°x40° or 40°x45°) The fixture, thanks to the new concept optical system with rotating parabole (WxD 45°x40° or 40°x45°), allows to illuminate the surfaces with maximum horizontal or vertical beam opening. Operate as shown in the pictures below to set the vertical or horizontal parabole position (default position is 45°x40°). 1) Unscrews the six screws (S) on the head cover and remove it, pict 5 2) Loosen the two pommels (P) under the dicrhoic group (I), pict.5a 3) Rotate (clockwise) of 45°...
  • Page 8 To completely remove the dichroic unit (I) operate as shown in the pictures below 1) Cut the two clamps (N) 2) Open the spring lock (S) 3) Unscrew the four screws (Q) 4) Remove the wire protection (U) 5) Open the other three spring lock (S) on the three side of the dichroic unit (I) 6) Unscrew and remove the wire protection (V) 7) Disconnect the connecter (Z) and remove the dichroic unit (I) 8) Put again the two clamps (N) once the dichroic unit installation has been made...
  • Page 9: Control Panel

    THE CONTROL PANEL Here below you can see the control panel major screen. ___ Hercules ___ 0 01 Version 1.00 Serial 10001 DMX001 Next 012 Lamp STRK 15 : 35 Press any key pict.10 EXAMPLE 1: (...) ICON Choosed menu Select Address a menu...
  • Page 10: Control Panel Configuration And Fixture Management

    CONFIGURATION AND SETUP The equipment can works as follows: - DMX MODE: driving by controller DMX - STAND ALONE: manual working/automatic by the small panel at machine-border. In this case the item can manage others Hercules connected to the same DMX line and checking the switching On and Off at times, arranged by an internal clock at week- planning.
  • Page 11 TIME… (fix the time between no signal DMX and shutter closing) HRS COUNT > LAMP XXXX (lamp life) > FIXTURE XXXX (fixture life) DISPLAY FLIP YES (for overturn the display visual) > ADVANCED AUTO SHUT YES (To permit the automatically turning off of display within 30 seconds) BRIGHTNESS (to fix the display brightness) UTILITY >...
  • Page 12 DMX CHANNEL SETTING Enter into ADDRESS menu. Pressing button UP and DOWN you can set the value of required channel then you can push OK. Under the visualization of the current channel you can see even the channel number which must be set up in the next fixture. The number of channels used by Hercules 800 depends from the remote functionalities trained, such as switching off from remote and reset from remote.
  • Page 13 state. For make an alteration at operative mode, enter in menu UTILITY so in sub-menu PROGRAMS. The first voice sign if the equipment is set up like DMX, MASTER AUTO, MASTER MANUAL or SLAVE. Pressing OK it is possible change mode PROGRAMS The HERCULES 800 have two programs area.
  • Page 14 Head Office: STUDIO DUE s.r.l. Str. Poggino, 100 - 01100 Viterbo (Italy) tel. +39/0761352520 fax +39/0761352653 Asia branch: STUDIO DUE Far East LTD Unit D 29/F West Gate Tower 7 Wing Hong Street Kln. Hong Kong tel. +852/29542141 fax +852/23302515 www.studiodue.com...