If the coating has been damaged, Measure the roof area plane and stable surface. Non coated paint it with Lindab’s repair paint to There are various types of roofs but components must be unpacked and prolong the lifespan of the roof measure each roof part by multiplying stored in a dry and ventilated place.
Page 4
Assembly instructions Number of brackets and drain pipes The brackets should be mounted with c/c 600 mm. The end brackets are mounted 100 mm from the roof edge. The inclination of the gutter towards the down pipe should be at least 2,5 mm/m.
Page 5
Assembly – Quarterround Roof Drainage System Fascia bracket KVFK assembly Use bracket KVFK for perpendicular roof base. The inclination shall be 2,5 mm/m. Fascia bracket KVK07 assembly Use bracket KVK07 for perpendicular roof base. The inclination shall be 2,5 mm/m. Bend down the tabs while pushing the gutter down towards the bracket.
Page 6
Assembly – Quarterround Roof Drainage System Cutting gutter KVRA Place the gutter to be jointed in the brackets Use a hack saw to cut the gutter. and mark out the needed length Stop end KVGV & KVGH Remove the filings. Use silicone as sealing.
Page 7
Assembly – Quarterround Roof Drainage System Gutter and gutter outlet KVTP Place the gutter in the brackets and mark out for The hole is taken 68 mm from the back edge. For a correct hole, the gutter outlet can be the gutter outlet KVTP on the gutter.
Page 8
Assembly – Quarterround Roof Drainage System Gutter joint KVSK Place the gutter in the brackets. Use selfsealing gutter joint KVSK. Do not use Bend the back of the gutter against the front any silicone. and put on the KVSK. Place the other gutter in the brackets. Push the KVSK against the second gutter until it Close the gutter joint.
Page 9
Assembly – Roof Drainage System Down pipe bends Intermediate pipelength at BK 70° bends Check the measures to get the length of the Use a hack saw to cut the intermediate pipe intermediate pipe MST. Use table on the side. MST.
Page 10
Assembly – Roof Drainage System Close up assembly pipe holder SSVU It´s easily done to dismount the holder. Pipeholder SSVU with SST or SSC Cut of the legs for use of SSVU SST..or SSC. with SST and SSC.
Page 11
Assembly – Roof Drainage System Adjustable shoe FUTK Adjustable branch GRÖR 50º 80º Connect a branch pipe. Can be mounted in angle 50-80°. Leaf filter DVSIL Connect the drain shoe BUTK Use IMR in the same color as your rainwater system to cover the pipe from the ground.
Page 12
At Lindab, good thinking is a philosophy that gui- des us in everything we do. We have made it our mission to create a healthy indoor climate – and to simplify the construction of sustainable buil- dings. We do that by designing innovative pro- ducts and solutions that are easy to use, as well as offering efficient availability and logistics.