Restocking Policy All product returned to Pribusin Inc. in prime condition (not damaged, scratched or defaced in any way) within seven (7) months from the original date of shipment is subject to a 50% restocking charge. All product must be accompanied by a Return Authorization number (RA number) which must be obtained from Pribusin Inc.
Model: ITC-79-FTF Manufacturers of Process Frequency To Frequency Isolator Controls and Instrumentation Standard Features: DIN-Rail Mount (small size) High Input-Output-Power Isolation (800VAC Test) Wide Input Frequency Range (from 0 Hz to 10 KHz) Many Input Types & Ranges (Voltage, Dry Contact) 3 Standard Outputs (TTL, 24V, Dry Contact) Optional Buffer or Divider Function Adjustable Response Time for Noise Rejection...
ITC-79-FTF-DIV: Frequency Isolator with Divider Outputs: TTL, 24VDC, Dry Contact Function: Divide Input by Division Factor Manufactured By: USA: CANADA: Pribusin Inc. Pribusin Inc. 743 Marquette Ave 101 Freshway Dr. Unit 57 Muskegon, MI 49442 Concord, Ontario, L4K 1R9 www.pribusin.com...
Page 7
Calibration & Setup Procedure for ITC-79-FTF (includes ITC-79-FTF-BUF & ITC-79-FTF-DIV) 1. Factory Settings: (unless otherwise specified at time of order) ITC-79-FTF: Input Type: Voltage Input, TTL level (0-5 VDC) (jumper H2-8 inserted) Thresholds: ON: TP1 = 3V OFF: TP2 = 1V Relay &...
Page 8
1 msec insert jumper H2-3 100 microsec insert jumper H2-2 10 microsec insert jumper H2-1 For Example, if the maximum frequency is 2000 Hz, the period is 1/2000 sec. or 500 micro seconds. Choose either 100 micro seconds or 10 micro seconds. If you were to choose 1 msec or 10 msec, the input could not respond fast enough to your highest input frequency and the ITC-79-FTF would not accept the input.
Page 9
5. Output Type: The ITC-79-FTF has three standard output types. These are Dry Contact, TTL (5V), and 24 VDC. To activate the TTL output, jumper H4-4 must be inserted (factory default setting). To activate the relay and 24 VDC output, jumper H4-1 must be inserted.
Page 10
7. Additional Setup & Calibration for ITC-79-FTF-DIV only: The ITC-79-FTF-DIV takes the incoming pulses (frequency) and provides a 50% duty cycle square wave output that is divided by an adjustable division factor. division factor can be in the range of 1 to 65535 and is encoded in binary on the jumper strip H1.