Ventilation & air filtration system for a residential safe room (12 pages)
Summary of Contents for BE Rainbow 36 V
Page 1
Rainbow 36 V User’s Manual Beth-El Industries Ventilation & Air Filtration System for a Residential Safe Room Approved by the Civil Defense Command and the Standards Institution of Israel In accordance with Israel Standard 4570 2015...
System Parts List ......................4 System’s Principle of Operation ................. 6 Using the System ......................8 Routine Storage ......................10 Troubleshooting ......................11 Contact Information ..................back cover Rainbow 36 V Ventilation and Air Filtration System · for a Residential Safe Room www.beind.co.il...
Keep this manual in an appropriate place, so that it will be available in the event of an emergency. It is also recommended to practice operating the system from time to time, but without removing the filter’s sealing caps and without attaching...
(Installed on the overpressure blast valve) Bracket for the manual blower (Present in systems where the height of the inlet valve is above 1.6 meters) Rainbow 36 V Ventilation and Air Filtration System · for a Residential Safe Room www.beind.co.il...
NBC masks (on condition that the room is not contaminated by NBC before operating the system). The slight overpressure that is created in the room is not harmful to humans or pets. Rainbow 36 V Ventilation and Air Filtration System · for a Residential Safe Room www.beind.co.il...
Page 6
Beth-El Industries Instructions for Operating the System Important! The system should only be operated in an actual emergency situation and in accordance with the instructions of Civil Defense Command. Attention! Before operating the system, make sure that all doors and windows are closed and sealed properly.
Page 7
In the event that the indicator vane doesn’t rotate, this is a warning that the room is not properly sealed. Rainbow 36 V Ventilation and Air Filtration System · for a Residential Safe Room...
Operation by means of the manual blower In the event of a power outage or other problems with the electric blower, the system can be operated by means of the manual blower. The manual blower can be attached in two possible positions:...
Page 9
(3). Step 2 Be sure that the other end of the connecting hose is attached to the opening of the air outlet of the filter (1).
If the filter has adsorbed NBC substances, proceed in accordance with the instructions of the Civil Defense Command. At the end of the emergency situation, the company should be summoned for a service check and maintenance of the filter.