Download Print this page

G&L E100 Installation Manual page 140

Advertisement

Downloaded from
Elcodis.com
electronic components distributor
AJ71C24-R4/A1SJ71UC24-R4/A1SJ71C24-R2/A1SJ71UC24-R2
Station number:
When communicating with the E-series: 0
Mode setting:
When communicating with the E-series: A1SJ71C24-R4/A1SJ71UC24-R4: 5
A1SJ71C24-R2/A1SJ71UC24-R2: 1
Setting of the switches:
Default
comm.
Switch
settings in
Setting items
software to
E-series
SW01
OFF
Main drop set-
Only -R4
tings
SW02
ON
Computer link/
Only -R4
Multidrop
SW03
OFF
Unused
SW04
ON
Write during
RUN
SW05
OFF
Transmission
speed setting
SW06
ON
SW07
ON
SW08
ON
Data length
SW09
OFF
Parity check
SW10
OFF
Parity setting
SW11
OFF
Stop bit
SW12
ON
Sum check
Position of Setting
Switch
Notes
ON
OFF
Master
Local sta-
Valid only
station
tion
when SW2 is
OFF
Compu-
Multidrop
Must be ON
ter link
link
Enabled
Disabled
For dedi-
cated protocol
Refer to the table below
8 bits
7 bits
Enabled
Disabled
Even
Odd
Valid only
when SW09
is ON
2 bits
1 bit
Enabled
Disabled
For dedi-
cated protocol