LedgeCircle RF Manual
122577 EN Rev. E04 - 0920
NB! Please find the manual in other languages
on www.defa.com or scan the QR code.
Norsk
Svensk
1
www.defa.com

Advertisement

loading

Summary of Contents for DEFA LedgeCircle RF

  • Page 1 LedgeCircle RF Manual 122577 EN Rev. E04 - 0920 NB! Please find the manual in other languages on www.defa.com or scan the QR code. Norsk Svensk www.defa.com...
  • Page 2 - Note that the Radar sensor may be triggered by motion on the other side of doors and windows. Adjust the sensitivity / range of sensors according to the conditions. - LedgeCircle RF fittings communicate at the 868Mhz frequency. Telecom antennas using the ® 800Mhz and 900Mhz bands may cause fittings to be permanently on. This is most likely to occur at the top floors of buildings with or near such antennas. How it works Each LedgeCircle RF fitting can receive activation signals from up to 30 other fittings and be set to respond ® either by turning on to the Max level (usually 100%) or to the selected Standby/Min level (10, 20, 30 or 50%). By configuring the sensor and communication settings, a LedgeCircle RF installation may be set up to be- ® have in a wide variety of ways, depending on your needs. See further instructions on connection and configuration in the following sections. Radar activation - example 1: All connected fittings react respond to activation signals by turning ON to the Max level (100%). MinMaxOnOff mode. 100% 100% 100% - All fittings are OFF by default. - The first fitting to detect motion sends an activation signal and turns ON to the Max level. - All connected fittings respond to the activation signal in the same way. - This ensures that the light will be on well ahead of the person moving through the building. www.defa.com...
  • Page 3 RF Radar | MinMaxOff 100% 100% 100% - As a person moves through the building, each fitting detects motion and continues to signal the others to stay on. - The Hold Period and subsequent Standby Period (see Sensor Manual) does not start running until no more activation signals are received. - The Hold and Standby Periods start running at the same time for all connected fittings. This means that they also turn off at the same time. 100% 100% 100% - Since all connected LedgeCircle RF fittings detect motion forward activation signals to each other, ® the installation behaves in the same way no matter which fitting first detects motion.  100% 100% 100% Hold Period  Standby Period  - The Hold Period starts when after the last detection/activation signal has been received. The light remains at the Max level during this period. Once the Hold Period expires the light goes down to the to the selected Min level for the Standby Period. - Detection range, Hold and Standby Period duration and Standby dimming level can be configured with the remote. www.defa.com...
  • Page 4 - Fittings on the same floor respond to the activation signal in the same way. - The first fitting on the floors above and below respond by turning ON to the selected Standby/ Min level, and the Standby Period starts running. 100% 100% 100% 100% - A person moving to the second floor is detected by the first fitting, already at the Standby Min level. - The fitting goes from the selected Min level to 100% and sends an activation signal. - Fittings on the second floor respond by also turning ON to the Max level. - The stairwell fitting in the third floor responds by turning ON to the selected Standby level. - The fittings in the first floor remain at the Max level for the duration of the Hold Period. 100% 100% 100% 100% - Note that when the fittings in the first floor are not already on (e.g. the person is leaving from the second floor), the stairwell fitting on the first floor 100% 100% 100% 100% will also respond by turning ON to the selected Min level. www.defa.com...
  • Page 5 - When the Hold Period expires for the fittings on the first floor, they turn down to the selected Min level for the duration of the Standby Period. - Since all connected LedgeCircle RF fittings ® detect motion and forward activation signals to each other, the installation behaves in the same 100% 100% 100% 100% way no matter which fitting first detects motion. 100% 100% 100% 100% - All fittings in the first floor turn off at the same time when the Standby Period expires, except when the Standby Period is set to indefinite 100% 100% 100% 100% (MinMax mode / Eternity sign). - The fittings in the second floor go to the selected Standby/Min level for the duration of the Standby 100% 100% 100% 100% Period. - Detection range, Hold and Standby period duration and Standby dimming level can be configured with the remote. www.defa.com...
  • Page 6 - Now, point the remote to the Fitting 1 and press “Transmit”. - The fittings in Learn-mode will confirm that the pairing has been established by beeping rapidly 3 times. They will now all respond to activation signals from Fitting 1. - To interconnect all fittings, now point the remote to Fitting 1 and press and hold the “Learn/Erase” button until it enters Learn-mode. - Place fittings that have completed the "Transmit" to one side, apart from those who have not. - Now select another fitting (Fitting 2) and take it out of Learn-mode by pointing the remote to it and pressing the “Learn/Erase” button. - Point the remote to Fitting 2 again and press “Transmit”. - As before, all fittings in learn mode will beep rapidly 3 times to confirm that the pairing is successful. - Repeat above steps until all fittings have learnt to respond to activation signals from all other fittings. Selecting responses - Responses are selected with the RX 100% and RX STBY% buttons on the remote. - By selecting RX STBY% the fitting will go to your selected Standby dimming/Min level when activated. - This also means that the fitting will go straight to the Standby Period. Once your selected Standby Period duration expires, the fitting will turn OFF. - Point the remote to each fitting and press the button corresponding with your preferred response. - The factory setting for LedgeCircle® RF fittings is RX STBY%. Mounting - NOTE! Please read the sensor and configuration instructions before mounting. - Be aware that each fitting as a maximum indoor communication range of 30 meters. - For instructions, see the separate mounting manual provided with each fitting. www.defa.com...
  • Page 7 Reset function Press “RESET”, to restore default settings. Shift Press "shift" to use secondary button values marked in red. "Shift-mode" is active for 20 seconds. Auto Mode Press “AUTO” to initiate automatic mode. In this mode the sensor and fitting behave according to your selected settings. Shift + This feature is not available with LedgeCircle ® fittings. Power output Press "Power 80%" to reduce power input to 80%. This can be done during the first year or the first 10,000 hours of use, when the light output is usually above the required amount. Note that fittings must be returned to 100% manually (with the remote). Brightness +/- Use these buttons to adjust the light Output during the Hold Period. Scene programming 1. Press “Start” to begin programming. 2. Choose your settings for the scene with the appropriate buttons. 3. Press “Memory” to save the created scene in the remote control. 4. Press “Apply” to use the scene in each fitting. www.defa.com...
  • Page 8 Hold Period (Hold Time) Use these buttons to set the Hold Time to 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min. To set Hold Time to 30s / 5min / 15min / 30min, press the “Shift” button first. Standby Period (Standby Time) Use these buttons (+ Shift for red values) to set the Standby Period to 0s / 10s / 1min / 5min / 10min / 30min / 1h / + . Use "0s" to set the fittings to On/Off mode (no Standby Period). Use ("+ ") to set the fittings to MinMax mode. The fitting will remain at the selected Min level indefinitely. Standby dimming level Set the Standby dimming / Min level to 10% / 20% / 30% / 50%. Dual Tech & RF mode Use the Learn/Erase and Transmit buttons set up connections between fittings, see "How to set up your installation" on page Factory settings: 6. Use RX 100% And RX STBY% to select whether the fitting - Sensitivity: 100% should go to 100% or to the selected Standby light level via - Hold period: 1 min. radio communication. - Standby period: 5 min. - Standby dim level: 20% - Daylight threshold: Disable www.defa.com...