PG-4G is a 12-channel transceiver of panic signals transmitted from or
to other PG-4G units. The panic transmission can be triggered by the
remote controls (RC-11, RC-22, RC-28).
If the unit is triggered by the remote control it will send the signal to
other units that have been enrolled to the one, which is transmitting the
panic signal. The received signal is indicated by the corresponding LED
diode placed on the front panel of the unit. By the position of the active
LED diode is to be found from which unit (place) the signal was sent.
Activation can be also indicated by the built-in buzzer (depending on a
jumper BUZZER) or by an external siren, flashing light, telephone dialer
etc.
It also cooperates with a pocket receiver PG-4R. Every panic signal is
sent to all enrolled PG-4G units as well as to the receivers PG-4R.
Specification
Power supply:
Stand-by consumption:
Maximal supply current:
Max output load:
Output OUT for TD-101connection
Dimensions:
Working environment:
Working temperature:
Built-in receiver of the remote controls
Compatible remote controls:
Number of controllers:
Coding:
digital, each remote control has a unique floating code
Working distance:
Operating frequency:
Built-in receiver/transmitter for communication with other units
PG-4G
Number of cooperating units:
Coding:
Working distance:
Operating frequency:
Transmitting time
Radiated power
External antenna (optional)
Wireless local indication of the activation (optional)
Compatible receivers:
Number of receivers:
Working distance:
In Norway and Belgium can be operated according to ERC REC 70-03
as e SRD.
Hereby, Jablotron Ltd. declares that this PG-4G is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.cz, section Technical support.
Note: Although this product does not contain any harmful materials we
suggest you to return the product to the dealer or directly to the
producer after usage.
Installation
The metal case should be installed on a wall with its antenna in a
vertical position. The unit should not be installed close to any metal
structures or other objects obstructing radio signal transmission.
Route the wires through the hole in the rear part of the housing. Attach
the case to the desired place using the provided screws.
Terminal description:
+12V, GND
DC power input 12 V DC
OUT
Output for a telephone dialer (TD-101) activation,
connected to ground in case of the alarm, max. load 5mA)
SIR
output for external indication 12V / 250mA max, timeout
60 minutes
+U, GND
DC power output 12 V DC 100mA max
PG-4G
PG - 4 Guard
12 V DC
55-100mA
12 V, max. 250mA
12 V, max. 5mA
188 x 135 x 40 mm (without antenna)
indoor use (class II)
-10 to +40
RC-11, RC-22, RC-28
up to 30
depending on the remote control -
Max 100m open area
433.9 MHz, ISM EN 300220
up to 13
up to 2 km (open area)
448.17 MHz
Yes, type AN-01A, AN-02, AN-03
PG-4R, PG-4M
unlimited
up to 2 km (open area)
Indicators and controllers for installation/service
The indicators 1-12 on the cover indicate the status of the unit during
the learning mode. Buttons
control the learning mode (see figure 1).
0,5 A
Other controlling buttons/jumpers are placed on the main board (see
figure 2):
o
C
T RANS MIT ER
digital
3 sec.
0.5 W
JP1
BUZZER
Button LEARN
LED
LEARN
LED
TEST
Button TRANSMIT to transmit the enrolling signal to other PG-4G
LED TRANSMIT
Jumper JP1
Jumper JP4
Jumper BUZZER
RS-232
ANT
EXP
Recommended procedure of setting
1.
First of all enroll the remote controls to each unit.
2.
If any receivers PG-4R (M) are used enroll them after that.
3.
Enroll other PG-4G units.
1/2
and
(up or down) are used to
figure 1
ANT
RECEIVER
ADRESS
RS 232
figure 2
to enroll the remote controls
indicates opening of the enrollment mode
indicates activation of enrolled remote control in
the test mode (JP1)
units
indicates the transmission of PG-4G
right position – if the unit is triggered by the panic
button it will start transmitting to other PG-4G
units as well as to the local receivers PG-4R if
there are any
left position – if the unit is triggered by the panic
button it will start transmitting only to other PG-
4G receivers
Close upper and middle pins to test the remote
controls
Open – normal function
Close – to switch ON the built-in buzzer
Open – to switch OFF the built-in buzzer
connector for PC connection (RS-232)
AN-01A external antenna connector (when AN-
01A
is
used,
the
disconnected)
connector for external communication
LEARN
T RANS MIT
T EST
JP4
EXP
rod antenna must
be
MEG52202

Advertisement

loading

Summary of Contents for jablotron PG-4 Guard

  • Page 1 LED TRANSMIT indicates the transmission of PG-4G Hereby, Jablotron Ltd. declares that this PG-4G is in compliance with Jumper JP1 right position – if the unit is triggered by the panic the essential requirements and other relevant provisions of Directive button it will start transmitting to other PG-4G 1999/5/EC.
  • Page 2 Erasing of enrolled units When any other remote control or receiver PG-4R is being enrolled the panic signal will be transmitted to all cooperating units. Please   • Using button (up or down) open the learning mode and do not forget to announce it to all cooperating units prior to any select the desired position (LED diode is flashing-Red/Green).
  • Page 3 Description of the setting software PG-4G Name of opened To set a new To open the To save the To set the Address of the project project existing project project COM port connected PG- 4G unit To show the Status of the enrollment table communication see tab.