Silvan Selecta SELECTA SQDN100-P1 Instruction Manual

Silvan Selecta SELECTA SQDN100-P1 Instruction Manual

100, 200, 400, 600l diesel transfer unit

Advertisement

Quick Links

Instruction Manual
MANSQDN100 REV E 27/04/20
VICTORIA (HEAD OFFICE)
Telephone: +61 (03) 9215 2700
Fax: +61 (03) 9215 2701
www.silvan.com.au
100, 200, 400, 600L DIESEL TRANSFER UNIT
SILVAN AUSTRALIA PTY. LTD.
ABN 48 099 851 144
SQDN100-P1, SQDN100-1,
SQDN200L-Z1, SQDN200-7,
SQDN400L-Z1, SQDN400-7,
SQDN600L-X1
NEW ZEALAND
Hamilton, New Zealand
Telephone: +64 (07) 8496 033
Fax: +64 (07) 8496070
www.silvannz.co.nz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SELECTA SQDN100-P1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Silvan Selecta SELECTA SQDN100-P1

  • Page 1 Instruction Manual MANSQDN100 REV E 27/04/20 100, 200, 400, 600L DIESEL TRANSFER UNIT SQDN100-P1, SQDN100-1, SQDN200L-Z1, SQDN200-7, SQDN400L-Z1, SQDN400-7, SQDN600L-X1 SILVAN AUSTRALIA PTY. LTD. ABN 48 099 851 144 VICTORIA (HEAD OFFICE) NEW ZEALAND Telephone: +61 (03) 9215 2700 Hamilton, New Zealand Fax: +61 (03) 9215 2701 Telephone: +64 (07) 8496 033 www.silvan.com.au...
  • Page 2: Warranty Exclusions

    Warranty Silvan Warranty Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
  • Page 3: Safety Instructions

    Safety Instructions Before attempting to operate or install the diesel unit carefully read and take note of the following safety warnings. Failure to comply with these warnings may result in serious injury or death. Warning! This Diesel unit is designed and manufactured solely for the purpose of carrying and pumping Diesel fuel.
  • Page 4 Safety Instructions (cont.) The location and wording of the safety decal fitted to your Silvan Diesel tank is shown below. It is important that all operators read and follow the information on all safety decals before operating the unit. Failure to comply with these warnings could result in serious injury or death. Safety decals should be kept clean and legible at all times.
  • Page 5: Specifications

    Specifications GENERAL: All transfer units come standard with an Auto shut-off gun and all pumps feature a duty cycle for 30 minutes of continues dispensing, all pumps also contain an internal bypass that allows for the pump to operate for up to a maximum of three minutes when the filling nozzle shuts off without damaging the pump or motor.
  • Page 6: Operation And Installation

    Operation and Installation PREPARING THE TRANSFER UNIT FOR OPERATION: For transport purposes some transfer units will be supplied with the Delivery hose and Automatic Shut-off gun disconnected from the pump. Before attempting to pump any Diesel ensure that the delivery hose is securely fitted to the pump’s outlet, and that the Automatic Shut-off gun (with swivel) is fitted to the other end of the delivery hose.
  • Page 7: Troubleshooting Guide

    Troubleshoot TROUBLE SHOOTING GUIDE Problem Solution • Ensure battery wires are connected to battery properly. Red Pump does not operate Clip to +ve • Check Fuse (25A) under plastic pump switch cover is intact. • Remove pump end cover, connect power to White & Black wires to test •...
  • Page 8: Pump Specifications

    Pump Specifications Pump Volts Open Motor Duty Internal Delivery Pump Model Type Amps Name (DC) Flow Cycle Bypass Hose DIESEL meters POWER 40L/min 30 minutes (20mm 2000 I.D.) meters PUISI 45L/min 30 minutes (20mm BP3000 I.D.) PUISI meters BP3000 45L/min 30 minutes (20mm INLINE...

Table of Contents