Advertisement

Quick Links

Operating Instructions
THI · THIP · TCO LAN data loggers
BA-THI-THIP-TCO-01-EN

Advertisement

Table of Contents
loading

Summary of Contents for infoAgro THI

  • Page 1 Operating Instructions THI · THIP · TCO LAN data loggers BA-THI-THIP-TCO-01-EN...
  • Page 2: Table Of Contents

    Please read this manual carefully. These instructions are designed to ensure Table of Contents that your data logger is used for the purpose for which it was intended and to guarantee that you get the maximum benefit from your product. These operating instructions describe the functions of the hardware.
  • Page 3: Features

    3. Features Battery compartment Mode selection key Battery compartment lid Data loggers with internal sensors (THI /THIP /TCO) USB micro B port RJ45 network connection 4. Scope of Delivery Mounting rail LCD display : The following components are contained in the standard scope of delivery: Measuring value line 1 •...
  • Page 4: Preparations Prior To Use

    6. Operating the Data Logger 5. Preparations Prior to Use The SmartGraph PC software forms the central configuration interface for your 5.1. Software data logger. All further changes to the configuration or display can only be carried out using the software. 5.1.1.
  • Page 5: Network Function (M51)

    Operating Mode M2 A signal transmitted by the data logger via UDP enables the SmartGraph soft- ware to find the data logger in the local network automatically. When the data logger is connected to the network for the first time (add network device), you may have to use the SmartGraph software to adapt the data logger network settings to conform with the existing network configuration.
  • Page 6: Measuring Value Display And Data Logging

    (max) and the average value (avg). This means that your THI data logger has a total of 24 measuring channels, as shown in table 1. The data logger is in logging mode (REC) when the operating modes M3 or M4 have been selected.
  • Page 7: Alarm Function

    8. Alarm Function 8.1. Alarm Configuration 8.3. Acoustic Alarm The data logger management can be used to configure an alarm for each indi- When an alarm is triggered when the acoustic function is active (see chapter vidual measuring channel which has been selected for display or logging. 6.2.4.
  • Page 8: Cleaning And Maintenance Instructions

    9. Cleaning and Maintenance Instructions 9.1. Replacing the Batteries 9.2. Installation During Mobile Operation When the message “LO bAtt” appears on the display, The data logger can be placed at any random position during mobile operation. the batteries have to be replaced. Please make sure that the permissible environmental conditions are observed (see Technical Data).
  • Page 9: Technical Data

    10. Technical Data Technical Data THIP Principle Measuring range -20 °C to + 50 °C Air temperature Accuracy ± 0.3 °C (0…40 °C), otherwise 0.5 °C Display resolution 0.1 °C Principle capacitive Measuring range 10 to 95 % RH Rel. humidity Accuracy ±2 % RH Display resolution...

This manual is also suitable for:

ThipTco