Do you have a question about the Thermo King TouchPrint Series and is the answer not in the manual?
Questions and answers
Summary of Contents for Ingersoll-Rand Thermo King TouchPrint Series
Page 1
Installation Manual Installation Manual Installation Manual Installation Manual Installation Manual Installation Manual TouchPrint™ SB-210+ SB-210+ SB-210+ Installation Manual for Truck Additional text information Additional text information Additional text information and Trailer Units to be placed here to be placed here to be placed here TK 5XXXX-X-PL TK 5XXXX-X-PL...
Page 3
TouchPrint™ Installation Manual for Truck and Trailer Units TK 56199-11-IM (Rev. 0, 07/15)
Page 5
TouchPrint Standard and Premium Kit Components 401192 401193 TouchPrint Standard TouchPrint Premium Part # Description Qty. (1 Serial Port) (3 Serial Port) 452544 TouchPrint, Standard ---- 452545 TouchPrint, Premium ---- 420967 Sensor, NTC 10K, length 18M ...
Page 6
TOUCH PRINT INSTALLATION MANUAL Alarm 1A Max Connect + to 2 and 3 to avoid sleep mode (when using telematics) PIN 1 PIN 2 PIN 3 PIN 4 TOUCH PRINT PIN # COLOR CONNECTION PIN 1 PIN 2 YELLOW 401192 PIN 3 BLACK 401193...
Page 7
TOUCH PRINT INSTALLATION MANUAL Bill of Material INSTALLATION KIT TRAILER (902613) Posi DESCRIPTION ENCLOSURE ASSY, TOUCHPRINT TRAILER PANEL FRONT, TRAILER TOUCHPRINT GLAND M12x1.5 ST 3 / 4 GLAND M12x1.5 REDUCED LOCKNUT M12x1. HOLDER, FUSE FUSE 2 AM CABLE POWER 3M, TOUCHPRINT PAPER ROLL, SINGLE SCREW AF 5.5x32 SCREW M 4x10...
Page 8
TOUCH PRINT INSTALLATION MANUAL Bill of Material INSTALLATION KIT TRUCK RADIO (902614) Posi on # Descrip on BRACKET FUSE HOLDER FUSE 2 AMP CABLE POWER 3M, TOUCHPRINT PAPER ROLL, single Set point – Premium model only J9/J10...
Page 9
INSTALLATION MANUAL TOUCH PRINT 1. Basic Menu Operation 03/03/2012 18:33 I1 : -10.5°C I4:-10.5°C I2 : 5.5°C OPEN I3 : CLOSE 2. Language Selection LANGUAGE SELECTION Current ENGLISH FRENCH 3. Cancel Printing...
Page 10
INSTALLATION MANUAL TOUCH PRINT 4. Change Contrast Settings CONTRAST CONTRAST Enter Enter Password is 32010 5. Update Firmware PASSWORD PW = 32010 32010 Enter Press and hold 5 seconds DD / MM MM / DD 6. Printing a delivery ticket tabular format from midnight 03/03/2012 18:33 I1 : -10.5°C...
Page 11
INSTALLATION MANUAL TOUCH PRINT 7. Set the logging interval 03/03/2012 18:33 I1 : -10.5°C I4:-10.5°C I2 : 5.5°C OPEN I3 : CLOSE ■ ■ ■ (•) ■ ■ LOGGING TIME 05 MIN 8. Printing Data to Memory Stick 03/03/2012 18:33 I1 : -10.5°C I4:-10.5°C I2 :...
Page 12
INSTALLATION MANUAL TOUCH PRINT 9. Set Min and Max temperature alarm 03/03/2012 18:33 I1 : -10.5°C I4:-10.5°C I2 : 5.5°C OPEN I3 : CLOSE ■ ■ ■ (•) ■ ■ PASSWORD ALARM MENU ▲▼ PW = 32010 GLOSSARY UPDATE BUZZER TIME Enter Enter ALARM MENU...
Page 16
Ingersoll Rand’s Climate Solutions sector delivers energy-effi cient HVACR solutions for customers globally. Its world class brands include Thermo King, the leader in transport temperature control and Trane, a provider of energy effi cient heating, ventilating and air conditioning systems, building and contracting services, parts support and advanced controls for commercial buildings and homes.
Need help?
Do you have a question about the Thermo King TouchPrint Series and is the answer not in the manual?