Epcom SF6200MA User Manual

Epcom SF6200MA User Manual

Voice evacuation & public address system

Advertisement

Quick Links

USER MANUAL
VOICE EVACUATION & PUBLIC
ADDRESS SYSTEM
SF6200MA
SF6200MS
Thanks for using EPCOM Voice Evacuation& Public Address System.
For better operation, please read this manual carefully before operating the system.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SF6200MA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Epcom SF6200MA

  • Page 1 USER MANUAL VOICE EVACUATION & PUBLIC ADDRESS SYSTEM SF6200MA SF6200MS Thanks for using EPCOM Voice Evacuation& Public Address System. For better operation, please read this manual carefully before operating the system.
  • Page 2: Table Of Contents

    Contents Contents................................2 1 Product renderings............................3 1.1 SF6200MA Product design sketch(2U)..................3 1.2 SF6200MS Product design sketch(2U)..................3 2 Main function introduction...........................4 2.1 SF6200MA Function feature......................4 2.2 SF6200MS Features.......................... 5 3 Main technical parameters Specifications....................6 3.1 Electrical Specifications........................6 3.2 Performance Specifications.......................6 4 Device function description........................11 4.1 Front panel function description....................
  • Page 3: Product Renderings

    1 Product renderings 1.1 SF6200MA Product design sketch(2U) FIGURE 1- 1 SF6200MAProduct renderings 1.2 SF6200MS Product design sketch(2U) FIGURE 1- 2 SF6200MS Product renderings...
  • Page 4: Main Function Introduction

    2 Main function introduction 2.1 SF6200MA Function feature  Built-in 500W amplifier, integrated 8 power A + B independent dual speaker loop partition output, each partition has a LED indicator, independent volume adjustment (6 files), forcibly cut to output power 100V when receive alarm signal.
  • Page 5: Sf6200Ms Features

    2.2 SF6200MS Features  Built-in 500W amplifier, integrated 8 power A + B independent dual speaker loop partition output, each partition has a LED indicator, independent volume adjustment (6 files), forcibly cut to output power 100V when receive alarm signal. ...
  • Page 6: Main Technical Parameters Specifications

    3 Main technical parameters Specifications 3.1 Electrical Specifications ① Power supply  Voltage ~ 110V ± 20%, 60Hz Fuse Size 4.5A  3.2 Performance Specifications ① Analog audio  microphone input  Sensitivity ± 2.5mV  Frequency response 200Hz ~ 10kHz ...
  • Page 7 ② Communication RS485 interface   Backup equipment RS485 interface  Support maximum baud rate of 38400bps  Supports up to 16 Backup equipments  CAN interface  Remote MIC console CAN interface  Baud rate of 38400bps  Supports up to 20 remote MIC consoles ③...
  • Page 8: Device Function Description

    4 Device function description The bellowed is front panel introduction for controller SF6200MA ( for SF6200MS detailed function, please refer to SF6200MAas they are with same front panel printing ): Figure 4- 1 SF6200MAfront panel design sketch 4.1 Front panel function description ...
  • Page 9: Rear Panel Function Description

    button, broadcast. MSG, then press ENERGENCY to close the  ACK/RESET: machine fault alarm reset button.  ALERT MSG: Play emergency evacuation voice.  EVAC MSG: Play fire alarm alert voice.  MONITOR :buttons to switch on and off monitor. ...
  • Page 10  SIGANL OUT: signal output interface, access to the standby amplifier input port. Note: When using the standby power amplifier, you need adjust its volume to the appropriate position to ensure the amplifier is 100V output.  SYS CONTRCL:  System Fault Output—When fault occurs, it will trigger and output a short circuit signal. ...
  • Page 11: Operation Instructions

    5 Operation Instructions 5.1 Self-test function 1. Power-on self-test: ① Connect the electricity AC 110V power supply. ② Turn the power switch to the ON position. ③ Can hear the relay beat sound when connect the electricity. ④ Panel indicator will show the current system status. 2.
  • Page 12: Local Sound Source Play

    2) Wiring diagram of level trigger mode (Note: Dry contact trigger mode can be configured on the PC, can configure level trigger or LINE 3 as a sound source, after the emergency trigger can not restore the original play state.) 5.3 Local sound source play ...
  • Page 13: Ptt Paging

    5.4 PTT paging PTT button Press the EMERGENCY button, then press the button on the PTT microphone to turn on the corresponding zone paging (need configure on PC). You can speak after the reminder tone. Please do not release the button during the speaking or it will automatically turn off paging and make a tone.
  • Page 14: Volume Control

    2) Short circuit test ------ Short circuit any zone output, do not need to press system fault self-test button on the front panel, Indicates light is orange and computer status short (short circuit). then connected to the speaker, press the self-test switch, and returned to normal state.
  • Page 15: Ip Address Reset

    1. Host volume control is control the volume of the entire machine, the adjustment will affect the 1 ~ 8 zone volume. Zone volume adjustment only adjusts the corresponding zone volume, does not affect other zones. 2. Amplifier output monitor Press the MONITOR button to turn on or off the monitor, Light on means amplifier monitor is turn on, light off means amplifier monitor is turn off.
  • Page 16: Voice Evacuation Router Address Settings

    5.9 Voice Evacuation Router address Settings Extended host address switch  Voice Evacuation Router address Table: DIP Switch Settings Voice Evacuation Controller Address...
  • Page 18 Version: 0.1...