Command
AT+ CIPSERVER
Set AT
AT+ CIPMODE
Query AT+CIPMODE?
Set AT+CIPMODE=<mode>
46
!
|
P a g e
"
Description
Configure as server
+CIPSERVER=<mode>[,<
port>]
Set module transfer
mode
"
Response
OK
!
Server has to be restarted
+CIPMODE:<mode>
!
OK
OK
!
If already connected,
returns
LINK IS BUILDED
September 17, 2014
Espressif
Systems
Reference
<mode>
0: Server mode OFF
1: Server mode ON
<port>: port number,
default value=333
!
Server monitor will
automatically be
created when Server
mode ON.
!
When a client is
connected to the
server, it will take up
one connection.
Server can only be
turned ON when AT
+CIPMUX=1
! !
! !
! !
! !
!
<mode>
0: No-passthrough
2: Passthrough