MAINTENANCE
The installation must be inspected and tested annually by a registered person (see item a)
on page 2) and any servicing and cleaning identified carried out. Servicing and removal of
the main cover must only be performed by an approved fitter or the manufacturer.
The heater should not be left for long periods without use. It is advisable to run the unit for
short periods throughout the summer.
The exhaust and inlet pipes should be inspected periodically for damage and any build-up
of dirt around the ends. Clean or replace as necessary.
The heater, its gas supply, and flues for the products of combustion are to be inspected in
accordance with national regulations or if these do not exist, the manufacturer's
recommendations, however, it is advised that this should be done at least annually.
LOCKOUTS
Lockout Clearing Procedure
The lockout must be cleared by turning the 'Fan Only' setting on the control panel, 'on', 'off'
and 'on' again within 2.5 seconds. If the first lockout reset attempt is unsuccessful, you can
retry an additional 4 times. If the lockout still will not clear (identified by a solid LED), please
turn off the heater, check the heater for faults, power up the heater and then further lockout
reset attempts can be made.
Manufactured By: Munster Simms Engineering
Distributed by; PROPEX HEATING & LEISURE LTD
Unit 10, Carvers Industrial Estate,
Ringwood, Hampshire. BH24 1JS
Tel: +44 (0)333 0110 488
Website: www.propexheatsource.co.uk
Email: info@propexheatsource.co.uk
180.121_0418
Issue 6L
Vehicle
Installation
&
Operation Instructions
From April 2018
E N G I N E E R E D
E N G I N E E R E D
F O R
F O R
C O M F O R T
C O M F O R T
&
&
R E L I A B I L I T Y
R E L I A B I L I T Y
Need help?
Do you have a question about the Heatsource HS2000 and is the answer not in the manual?
Questions and answers