45-0207 (Model 630B)
Cuvette Safety Stand
47-0208
Extended Capacity Flatpack Safety Stand
47-0203
AgilePulse MAX Cuvette Safety Stand
47-0209
AgilePulse MAX Extended Capacity Flatpack Safety Stand
47-0610N
AgilePulse PLUS Extended Capacity Flatpack Safety Stand
Safety Stands
USER'S MANUAL
Publication 5502-002 Rev 2.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BTX 630B and is the answer not in the manual?

Questions and answers

Summary of Contents for Harvard Bioscience BTX 630B

  • Page 1 Safety Stands USER’S MANUAL 45-0207 (Model 630B) Cuvette Safety Stand 47-0208 Extended Capacity Flatpack Safety Stand 47-0203 AgilePulse MAX Cuvette Safety Stand 47-0209 AgilePulse MAX Extended Capacity Flatpack Safety Stand 47-0610N AgilePulse PLUS Extended Capacity Flatpack Safety Stand Publication 5502-002 Rev 2.0...
  • Page 2 A Message from BTX Thank you for investing in a Safety Stand. Since its founding in 1983, the main focus of BTX has been in the area of applying controlled electric fields for genetic engineering applications. Because of this, we quickly established a reputation as the technological leader in the fields of electroporation and electrofusion.
  • Page 3: Table Of Contents

    Table of Contents SUBJECT PAGE # Warranty Information General Safety Information Introduction Operation: Getting Started Specifications Ordering Information Safety Stand 5502-002 Rev 2.0 • www.btxonline.com...
  • Page 4: Warranty Information

    Warranty Information Out of Warranty Service FOR RESEARCH USE ONLY Proceed exactly as for Warranty Service above. If our service 84 October Hill Rd department can assist you by phone or other correspondence, Holliston, MA 01746, USA we will be glad to help at no charge. Repair service will be billed on the basis of labor and materials.
  • Page 5 Safety Information High Voltage Risk Please read the following safety precautions to ensure proper use of your Safety Stand. If the equipment is used in a manner not specified, These BTX Safety Stands are designed to connect to a high voltage the protection provided by the equipment may be impaired.
  • Page 6: Introduction

    Introduction The BTX Safety Stand is a safety device for use with BTX disposable cuvettes and flatpack chambers. Its unique design ensures that no current can be delivered unless the lid is closed, therefore protecting the user from high voltages. Up to two cuvettes can be electroporated at once, thus decreasing experimentation times.
  • Page 7: Operation: Getting Started

    Operation: Getting Started Warning High Voltage Make sure the BTX electroporator is switched off before continuing. 1. Attach the safety stand cables to the output on the rear or the front panel of the electroporator depending on the BTX electroporator being used. For AgilePulse MAX, AgilePulse PLUS, and ECM 2001+, also connect interlock cable to front panel of electroporator.
  • Page 8: Specifications

    Specifications Standard Capabilities: Voltage Range 0 to 3000 VDC; 0 to 250 VAC Frequency 0.2 to 2.0 MHz Pulse Length/ 10 μs to 10 s Time Constants Range Other Specifications: Storage Temperature -10 to 70°C Operating Temperature 5 to 40°C Intended Use Indoor Use Only Relative Humidity...
  • Page 9: Ordering Information

    Ordering Information Safety Stands 45-0207 Cuvette Safety Stand (Model 630B) 1 Ea 47-0208 Extended Capacity Flatpack Safety Stand 1 Ea 47-0203 AgilePulse MAX Cuvette Safety Stand 1 Ea 47-0209 AgilePulse MAX Extended Capacity Flatpack Safety Stand 1 Ea 47-0610N AgilePulse PLUS Extended Capacity Flatpack Safety Stand 1 Ea Replacement Parts 45-0213...
  • Page 10 Contact Us US & Canadian Customers International Customers phone 508.893.8999 To locate a distributor 508.429.5732 near you, please visit our e-mail support@hbiosci.com website at www.btxonline.com website www.btxonline.com...