GENERAL DESCRIPTION

SPECIFICATIONS

General Coverage with standard wide-angle lens, measured indoors
at 20° C (68° F), typical:
C-101STLRE15: 15m x 12m. C-102 models only: "Look Down"
zone added.
Operating Temperature: -10° to +50° C (14° to 122° F)
Mounting: Wall or corner, 1.8m to 3m max.
Output Relay: Form C or Form A
Relay Time: Approximately 4 seconds
Contact Ratings: 100mA, 24Vdc with internal 10Ω current-limiting
resistor
Trouble: Form A, selectable N.O. or N.C.
Test Input: "TST" terminal: <6V (LED) enabled; >6V (or floating)
Test Mode (LED) disabled (internal pullup).
Self-Test Interval: 11-16 hours.
Power-Supply Requirements
Note: This unit is intended for operation from a power source that
provides battery backup in the event of a power failure. To meet CE
Flammability Requirements, this unit is to be powered by an agency
approved power supply meeting the requirements of EN60950 : 2000
clause 2.5 Limited Power Sources.
Filtered Dc: 12Vdc
Current Drain at 12Vdc: Idle, 37mA; Alarm, 40mA; Idle with trouble
relay NC selected is 12mA extra.
Microwave Frequency: 10.687GHz ±25MHz
Physical Dimensions: (HxWxD) 11.6 x 6.3 x 6.3 cm
Shipping Weight: 1.0lb (454gm)

FEATURES

• Microprocessor signal processing
• Power-up system diagnostic tests virtually all electronics
• Remote Control of Walk-Test LED
• Microwave and PIR self test
• Watchdog microprocessor supervision
• Microwave circuit supervision
• Dome of Protection for antimasking and antiblocking (selectable
option) with Range Control
• Trouble Output--Selectable N/C or N/O
• Automatic PIR operation on microwave failure
Dual-element PIR sensor
High-efficiency, dirt-resistant grooves-in lens
"Look-down" zone added for C-102 models only
Extensive RFI and EMI filtering ensure optimum immunity to
false alarms
Large lens area assures high PIR sensitivity
Selectable Microwave/PIR LED indication visible from virtually
any angle, extinguishable after testing.
Small size; modern, unobtrusive design
Silent operation
Bracket-free corner or wall mountable
Universal Swivel Bracket Kit available
ADVANCED ADAPTIVE PIR/MICROWAVE
TECHNOLOGY SENSORS
C-101STLRE11, C-102STLRE11
C-101STLRE15, C-102STLRE15
Installation INSTRUCTIONS
C-101STLRE11:
11m x 10.7m;

ORDERING INFORMATION

SVLBKT
Swivel Bracket Kit

BASIC OPERATION

This unit is a combination passive-infrared sensor and microwave
sensor, both contained in a single package. The unit will go into
alarm when both sensors detect intrusion at the same time. The PIR
section operates by detecting a rapid change in temperature when an
intruder crosses a protected area. When a beam experiences a
change in heat (projected back through the lens), a pulse is gener-
ated by the sensor element. The microwave transmitter sends out
short bursts of RF energy, and the receiver detects changes in the
returned signal caused by motion within its coverage area.
The microwave section is unaffected by visible light, air drafts, or
temperature changes (as from space heaters or air conditioners, for
example), but is sensitive to motion. Strong vibrations can be trouble-
some. Microwave signals may pass through non-metallic walls and
windows. Infrared is virtually unaffected by vibration, and will not
penetrate walls or windows.
Thus the two technologies complement each other, and it is the
combination of the two that provides an inherent immunity to false
alarms. Dual technology is ideal for use in hostile environments.
Since both must trip to cause an alarm, installation is easier and re-
quires less discipline.
11m
85°
Fig. 2a. C-102STLRE11 wide-angle lens pattern and "look-down" zone.
15m
85°
Fig. 2b. C-102STLRE15 Standard Wide-Angle Lens Pattern
and "look-down" zone.
WI1475 11/05
10.7m
1.8m
1.8
4
5.5
12m
1.8m
3
6
9
8
11 m
12
15 m
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C-102 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NAPCO C-102 Series

  • Page 1 C-101STLRE15, C-102STLRE15 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440 INSTALLATION INSTRUCTIONS Publicly traded on NASDAQ Symbol: NSSC WI1475 11/05 © NAPCO 2005 ORDERING INFORMATION GENERAL DESCRIPTION SVLBKT Swivel Bracket Kit SPECIFICATIONS General Coverage with standard wide-angle lens, measured indoors BASIC OPERATION at 20°...
  • Page 2 DETECTION PATTERNS Figures 2a & 2b illustrate maximum PIR and microwave detection JUMPER BLOCK J1 patterns superimposed on each other for each model. HEIGHT SCALE PIR SENSOR STANDARD LENS MICROWAVE RANGE ADJUST The supplied lens will perform best in typical applications, thus it is (TURN CLOCKWISE TO INCREASE factory installed.
  • Page 3 Look Down Zone Testing the Unit Coverage sensitivity is extended to the look down zone , located Complete connections to the terminal strip (see WIRING). The unit directly below the unit. To remove the Look Down Zone, simply re- will require a 1-minute “settling” time to adjust itself to the surrounding move the lens from the look down holder.
  • Page 4 NAPCO shall have NAPCO is not an insurer of either the property or safety of the user’s no obligation under this warranty, or otherwise, if the product has been...

This manual is also suitable for:

C-101stlre11C-101stlre15

Table of Contents