Do you have a question about the VTO65 Series and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Dahua VTO65 Series
Page 1
Digital Door Station (VTO65 Series) Quick Start Guide V1.0.0...
Page 2
Foreword General This manual introduces basic operations of the digital door station (VTO). For details, see the user manual. Model VTO6521H, VTO6521H-D, VTO6531H, VTO6541H VTO6521F, VTO6531F. Safety Instructions The following categorized signal words with defined meaning might appear in the manual. Signal Words Meaning Indicates a potential risk which, if not avoided, could result in property...
Page 3
Please visit our website, contact the supplier or customer service if there is any problem occurring when using the device. If there is any uncertainty or controversy, we reserve the right of final explanation. ...
Important Safeguards and Warnings The following description is the correct application method of the device. Read the Guide carefully before use, in order to prevent danger and property loss. Strictly conform to the Guide during application and keep them properly after reading. Operating Requirement ...
Structure The door station (VTO) has six models. Different models have different front panels but the same rear panel. Figure 1-1 Dimensions (mm [inch]) Table 1-1 Component description Description Description White illuminator Keyboard Loudspeaker Camera Fingerprint sensor Display Tamper button Function ports (connected to locks, access Card swiping area controllers, alarm in/out devices)
Installation Do not install the digital door station in environment with condensation, high temperature, and direct sunshine, and stained, dusty, chemically corrosive places. Engineering installation and test shall be done by professionals. Do not dismantle or repair arbitrarily in case of device failure. Contact after-sales service. Prepare cross screwdrivers and gloves yourself.
Page 9
Figure 3-2 Installation Table 3-1 Component description Description Description Description Door station Cable entry Wall — — Screw Mounting plate Installation Procedure Step 1 Cut an opening in the wall according to dimensions of the mounting plate. Step 2 Detach hole covers according to cable entry positions. Step 3 Put the mounting plate in the opening in the wall.
Web Configuration This chapter introduces how to initialize, connect, and configure parameters for the door stations to realize functions like device management, calling, and monitoring. For more details, see the user manual. Configuration Process Step 1 Plan IP address and number for each door station and indoor monitor. Step 2 Make sure that there is no short circuit or open circuit in the circuits.
Page 12
Figure 4-1 Device initialization Step 3 Enter and confirm the password, and then click Next. The email setting interface is displayed. The password should consist of 8 to 32 non-blank characters and contain at least two types of characters among upper case, lower case, number, and special character (excluding ' "...
Modifying IP Address To realize communication among video door phones, you need to modify IP address of the door station. You can modify IP address on the door station or through the web interface. Modifying IP address through the web interface will be demonstrated here. For IP address modification on the door station, see "5.2 Setting IP Address."...
Figure 4-4 SIP server Step 3 Select a SIP server. 4.4.1 Door Station (VTO) as SIP Server Step 1 Select the Enable check box next to SIP Server. Step 2 Select VTO from the Server Type drop-down list Step 3 Configure parameters (see Table 4-3 for details).
Page 15
Table 4-1 Device property description Parameter Description The door station can be used as unit door station and fence station. Select Device Type according to places where door stations are installed. Centre Call No. 888888 by default. The default value cannot be modified. VTO No.
Page 16
Figure 4-7 Step 3 Set indoor monitor (VTH) parameters by reference to Table 4-2. Table 4-2 Descriptions of adding indoor monitors (VTH) Parameter Description First Name Last Name Set username and nickname for each indoor monitor (VTH). Nick Name Set room number at the indoor monitor (VTH). ...
Figure 4-8 Adding indoor monitors (VTH) in batch Step 2 Enter Unit Layer Amount, Room Amount in One Layer, First Floor Number, and Second Floor Number. The unit layer amount range is 1–99, room amount in one layer range is 1–99, and first floor number range is 1–9999.
Page 18
Figure 4-9 SIP server Step 2 Select Express/DSS from the Server Type drop-down list. Step 3 Set parameters according to Table 4-3.
Page 19
Table 4-3 SIP server parameter description Parameter Description IP Address IP address of SIP server. It is 5060 by default when other door stations (VTO) rather than the one you are operating works as SIP server. Port It is 5080 by default when management platform works as SIP server.
Page 20
Figure 4-10 Device properties Step 3 Click Confirm. Table 4-4 Device properties description Parameter Description The door station can be used as unit door station and fence station. Select Device Type according to places where door stations are installed. Centre Call No. 888888 by default.
Engineering Setting Entering Engineering Setting Project interface is normally for administrators or engineers. You need to set the project password by selecting Local Setting > Access Control > Local on the web interface. Step 1 Press "*project password#" on the door station (VTO). The Engineering Setting interface is displayed.
User Registration Only users whose information, including username, personnel number, room number, fingerprint, and card number, is registered can unlock doors. Step 1 Press "*project password#" on the door station (VTO) to go to the Engineering Setting interface. Step 2 On the Engineering Setting interface, select User Registration.
Appendix 1 Notes of Face Recording Face Position If your face is not at the appropriate position, face recognition effect might be influenced. Appendix Figure 1-1 Appropriate face position Requirements of Faces Make sure that the face is clean and forehead is not covered by hair. Do not wear glasses, hats, heavy beards, or other face ornaments that influence face ...
Page 24
Appendix Figure 1-2 Head position Appendix Figure 1-3 Face distance When importing face images through the management platform, make sure that image pixels are more than 500 × 500; image size is less than 100 KB; image format is JPG; image background color is pure color (white is the best);...
Appendix 2 Fingerprint Record Instruction Notice Make sure that your fingers are clean and dry before recording your fingerprints. Press your finger to the fingerprint recording area, and make your fingerprint is centered on the recording area. Do not put the fingerprint sensor at places with intense light, high temperature, and high ...
Appendix 3 Cybersecurity Recommendations Cybersecurity is more than just a buzzword: it’s something that pertains to every device that is connected to the internet. IP video surveillance is not immune to cyber risks, but taking basic steps toward protecting and strengthening networks and networked appliances will make them less susceptible to attacks.
Page 28
between 1024~65535, reducing the risk of outsiders being able to guess which ports you are using. Enable HTTPS We suggest you to enable HTTPS, so that you visit Web service through a secure communication channel. Enable Whitelist We suggest you to enable whitelist function to prevent everyone, except those with specified IP addresses, from accessing the system.
Page 29
so as to achieve the network isolation effect. Establish the 802.1x access authentication system to reduce the risk of unauthorized access to private networks.
Need help?
Do you have a question about the VTO65 Series and is the answer not in the manual?
Questions and answers