Installation and start up instructions
TAS-331DG
Selectable AC transducer
4189300008G (UK)
Watt or var transducer
Supply and measuring voltage up to 690V
Configuration via PC-interface possible
35 mm DIN rail or base mounting
DEIF A/S
Frisenborgvej 33, DK-7800 Skive Fax:
Denmark
Tel.:
(+45) 9614 9614
(+45) 9614 9615
E-mail: deif@deif.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the TAS-331DG and is the answer not in the manual?

Questions and answers

Summary of Contents for Deif TAS-331DG

  • Page 1 Installation and start up instructions TAS-331DG Selectable AC transducer 4189300008G (UK)  Watt or var transducer  Supply and measuring voltage up to 690V  Configuration via PC-interface possible  35 mm DIN rail or base mounting DEIF A/S Tel.:...
  • Page 2 Description TAS-331DG is a micro controller based power transducer with 1 analog output for measurement of Watt or var. The transducer holds no mechanical moving parts like potentiometers and therefore the calibration stability is excellent. Label The configured transducer is provided with a label with the following data:...
  • Page 3 Installation and start up instructions, TAS-331DG Mounting instructions TAS-331DG is designed for panel mounting, being mounted on a 35 mm DIN rail, or by means of two 4-mm screws. Weight: Approx. 0.650 kg The design of the transducer makes mounting of it close to similar equipment possible, however make sure there is min.
  • Page 4 The transducer is protected against ESD (electrostatic electricity), and further special protection against this during the mounting of the transducer is not necessary. The below diagram illustrates how to connect a TAS-331DG in 2W3 configuration with a TAS-331DG in 2var3 configuration.
  • Page 5 Note this function is only activated in coupling 2W3, 2var3 and 3W3(4), 3var3(4). Fast pulse 5Hz. The calibration data are corrupted. Contact DEIF. Slow pulse 1Hz. The configuration data are wrong or corrupted. Make a re- configuration or contact DEIF. About configuration see special manual.
  • Page 6 Tel.: (+45) 9614 9614  Fax: (+45) 9614 9615  E-mail: deif@deif.com Page 6 of 8...
  • Page 7 Installation and start up instructions, TAS-331DG Technical specifications Accuracy: Class 0.5 (-10…15…30…55°C) according to IEC 688 Influence, phase angle: ≤ ±0.75° Meas. current (In) 0.75/1.5/3.0/6.0A Meas. range: 0…200% I can be set between 0.375…6A Overload, currents: 20A max., continuously 75A max. for 10 s 240A max.
  • Page 8 Housing: IP40. Terminals: IP20, to IEC 529 and EN 60529 Connections: Max. 2.5mm² multi–stranded Max. 4.0mm² single-stranded Materials: All plastic parts are self-extinguishing to UL94 (V1) Weight: 0.650kg Tel.: (+45) 9614 9614  Fax: (+45) 9614 9615  E-mail: deif@deif.com Page 8 of 8...