Download Print this page

Nice SecurityTronix ThermScan ST-THERMSCAN-1 User Manual page 2

Wall mounted non-contact forehead thermometer

Advertisement

Parts Included
Introduction
1. ThermScan Unit
2. USB Cable
3. USB Power Supply
4. Screws (2)
5. Anchors (2)
6. Double Sided Tape (4)
USB
7. User Manual
interface
Tripod
and Specifications
mounting hole
Specification
1. Accuracy: ± 0.4°F (± 0.2°C), for greatest accuracy place it in the operating environment
for 30 minutes before use. Requires a stable indoor climate controlled environment.
2. High Temperature Alert: Flashing +"Di Di" sound. Preset alarm comes on at 99.1˚F (37.3˚C)
3. Temperature Measurement Distance: 1.96 - 3.93" (5 - 10 cm)
4. Screen: Digital display
5. Powering method: USB supplied power or battery (18650 Li-ion).
6. Install method: Can be mounted with screws, double sided tape (included), or on a tripod.
7. Ambient Working Temperature: 50 - 104°F (10 - 40°C)
8. Testing Temperature Range: 32 - 122˚F (0-50°C)
9. Temperature Measurement Speed: Less than 1 second
10. Input: USB - DC 5V Power supply included
11. Weight: 0.77lbs (350g)
12. Dimensions: 6.69" x 4.52" x 5.51" (170 x 115 x 140mm)
14. Counting capacity: 999
Status Description
1. Standby: The red dot in the bottom of the display lights up from left to right. (Fig. 1)
2. Insufficient power: The horizontal bar lights up in the middle of the display. (Fig. 2)
3. Normal temperature: Flashing green lights and alarm 'Di'. (Fig. 3)
4. Abnormal temperature: Flashing red lights and alarm 'Di Di' indicate this
temperature. Preset alarm comes on at 99.1˚F (37.3˚C) (Fig. 4)
5. Default: (bod: object mode)
Lo: Ultra-low temperature alarm. (Fig.5) HI: Ultra-high temperature alarm. (Fig. 6)
Fig. 2
Fig. 1
Infrared thermometer
Infrared ranging sensor
Switch
Alarm
Mode switch hole
Temperature
light
display
Fig. 3
Fig. 5
Fig. 4
Operation Instructions
1. Temperature measurement: Approach the nozzle until the thermometer registers a
Double-sided
reading. Do not get so close that you touch the nozzle. Recommended distance:
adhesive area
2" - 4" (5 - 10 cm) (Fig. 7)
Mounting
holes
Nameplate
2. Mode switching: Settings can be changed using the small hole on the back of the
device (Fig. 8). Insert a 3mm screwdriver, and briefly press the button to change
between C° and F°. (Fig.9, 10)
The unit consists of 3 "modes" of operation. To change the "mode" of the unit, hold the
button for 3 seconds and release.
A. BOD (BODY) - This mode is used to when skin temperature is being read.
B. SUR (SURFACE) -This mode is used when surface temperature is being read
C. COU (Counter) - This mode display a digital counter. It is used to determine the
amount of readings the device has performed. *Does not display skin temperature
when used in this mode.
3. Install and replace battery:
1 - Remove three screws 2 - Open the back base and install 18650 Li battery
4. Install methods:
1 - Screws (Included)
mounting hole
spacing - 130mm
Fig. 6
1. Screws
5-10cm
32mm depth
Fig. 9
Fig. 8
2 - Double Sided Tape (Included)
2. Double-sided tape
ST-THERMSCAN-1 | 06262020
2 - 4"
Fig. 7
Fig. 10
-
+
3 - Tripod
3.Tripod

Advertisement