CONFIDENTIAL ® FLUID MANAGEMENT PROPERTY OF FLUID MANAGEMENT (C) COPYRIGHT 2001 AS AN UNPUBLISHED WORK ALL RIGHTS RESERVED This material cannot be copied or disclosed to others without Fluid Management the prior written permission of FLUID MANAGEMENT A Unit of IDEX, Corp. 1023 Wheeling Road Wheeling, Illinois 60090-5776 Voice...
Page 5
ASSEMBLY & INTRODUCTION INSTALLATION The Harbil NSC50 is a compact manual colorant dispenser that was designed for exceptional reliability and ease of use. It is a nearly maintenance free device that should deliver many years of reliable service. Its features include: •...
Page 6
It is critical that the crank be captured by the bushings that are part of the star wheel assembly. For machine configurations containing less than 12 canisters, hole plugs are provided (FM P/N 25956) to cover the unused canister positions.
Page 7
ASSEMBLY & INSTALLATION button holes, as shown in figure 3-A. Rotate canister clockwise locking it into place as shown in Figure 3-B. NOTE: The dispense port will fall through its hole, and the canister will sit flat on the turntable. 6.
Page 8
ASSEMBLY & INSTALLATION turntable to the next position. 9. Repeat steps 3-6 for each of the remaining canisters until all are installed. 10. After completing canister assembly, connect machine to power, and turn on the agitation switch. Verify that all the agitation blades are turning properly.
Page 9
ASSEMBLY & INSTALLATION CONNECTING TO THE POWER SOURCE GROUNDING In the event of an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. The 3- prong plug, equipped with grounding wire, must be plugged into a 3-slot receptacle that is properly installed and grounded in accordance with all local codes and ordinances.
Page 10
ASSEMBLY & INSTALLATION Connect the 115 volt models only to a 115 volt outlet rated at at least 15 ampere. Connect the 220 volt models only to a 220 volt outlet rated at at least 15 ampere. The equipment requires a single, grounded outlet. EXTENSION CORDS Extension cords for 220 VAC models are not recommended.
Page 11
ASSEMBLY & INSTALLATION FILLING CANISTERS After all of the canisters have been installed on the turntable, they can be filled. Each canister has a maximum capacity of 2-1/2 quarts. It is recommended that each canister be filled with two (2) quarts of colorant. The maximum capacity of the pump is two (2) ounces.
Page 12
BASIC OPERATION BASIC This dispensing equipment is designed for ease of use. The following steps represent the method by which a formula is to be dispensed: OPERATION 1. Determine the formula of the color selected by the customer. 2. Refer to the formula book and select the proper base paint. 3.
Page 13
MAINTENANCE PROCEDURES MAINTENANCE To ensure safe, dependable operation of the equipment, follow the maintenance schedule detailed below: PROCEDURES DAILY Cleaning & Filling: • Agitate colorants every morning for five (5) to ten (10) minites. • Clean nozzles & outside cabinet surfaces with soap and water. •...
Page 14
PARTS: EQUIPMENT MAINTENANCE LOG PARTS: RECORD MODEL NUMBER HERE: _________________________ RECORD SERIAL NUMBER HERE: _________________________ SERVICE SERVICED DESCRIPTION & PARTS REPLACED DATE (STATE IF UNDER WARRANTY) ® Fluid Management...
Page 15
SPARE PARTS ORDER Fluid Management Parts Order Form Photocopy and use this form to Mail or fax orders to: Fluid Management Phone: 1(800) 462-2466 A unit of IDEX 1023 Wheeling Road Fax: 1(847) 537-5530 Wheeling, IL 60090 Sold To: Ship To: Purchase Order Number: Ship Via: __________...
Page 17
PART NO DESCRIPTION NO REQ 07046 5/8”-11 NUT 1 PER CANISTER 24039 BUSHING 25030 CIRCLE SHEAR (12 CANISTER UNITS ONLY) 25032 DRIVE PLATE (12 CANISTER UNITS ONLY) 25033 CIRCLE SHEAR (12 CANISTER UNITS ONLY) 25219 CAM ASSY 25222 WHEEL 25224 SPACER 25225 MOTOR MOUNTING PLATE...
Page 19
PART NO DESCRIPTION NO REQ 07046 5/8”-11 NUT 23252 DRIVE MOTOR (220VAC/50HZ UNITS ONLY) 24039 BUSHING 1 PER CANISTER 25030 CIRCLE SHEAR (12 CANISTER UNITS ONLY) 25032 DRIVE PLATE (12 CANISTER UNITS ONLY) 25033 TURNTABLE (12 CANISTER UNITS ONLY) 25219 25222 WHEEL 25224...
Page 21
PART NO DESCRIPTION NO REQ 1 PER CANISTER 23243 AGITATION BLADE 1 PER CANISTER 24383 CRANK SHAFT 24831 TUBE (NOT SHOWN) 1 PER CANISTER 1 PER CANISTER 423100 VITON VALVE ASSY (NOT SHOWN) 1 PER STATION 4215000 CANISTER 50 OZ. (FOR 1 OZ. PUMP) 1 PER STATION 4215011 CANISTER 50 OZ.
Page 22
PARTS: COVER 23244 (STANDARD) 24584 (FOR SOLVENTS) DRIVE CANISTER PLATE ASSEMBLY 25032 25428 (1-OZ. PUMP W / VITON SEAL 4305004 (10-OZ. W / THIOKOL SEAL) TURNTABLE 25033 BOLT 12 CANISTER SYSTEM 02494 CANISTER DRIVE ASSEMBLY PLATE 4305004 25317 (1-OZ. PUMP W / VITON SEAL 4305011 (20-OZ.
Page 23
PART NO DESCRIPTION NO REQ 2 PER CANISTER 02494 MOUNTING BOLT, 14 X 20 X 1/2” 1 PER CANISTER 23244 CANISTER COVER (STANDARD) 24584 CANISTER COVER (FOR SOLVENTS) 1 PER CANISTER 25032 DRIVE PLATE (12 CANISTER UNITS) 25033 TURNTABLE (12 CANISTER UNITS) 25317 DRIVE PLATE (16 CANISTER UNITS) 25318...
Page 24
Part No. 4700220 Rev. F 10/01/12 Fluid Management 1023 Wheeling Road Wheeling, Illinois 60090-5773 Telephone: (847) 537-0880 1-800-462-2466 Fax (847) 537-5530 www.fluidman.com Part No. 4700220 Rev. F 10/01/12...