Electrical Wiring - Evcon DLAS Series Installation Instructions Manual

Sealed combustion downflow gas furnaces
Table of Contents

Advertisement

CAUTION
TO INSTALLER
DO NOT
HI-POT TEST THIS FURNACE. IF HIGH
POTENTIAL TESTS ARE REQUIRED ON THIS
MANUFACTURED HOME, THIS FURNACE MUST NOT
BE SUBJECTED TO THE TEST & MUST BE DISCON-
NECTED FROM ALL ELECTRICAL WIRING.
FAILURE TO FOLLOW THESE INSTRUCTIONS WILL RE-
SULT IN FAILURE OF THE AUTOMATIC IGNITION
PRINTED CIRCUIT BOARD AND RENDER THIS AP-
PLIANCE INOPERABLE.
DANGER
- SHOCK HAZARD -
DISCONNECT ELECTRICAL POWER SUPPLY TO THE
UNIT BEFORE SERVICING TO AVOID THE POSSIBIL-
ITY OF SHOCK INJURY OR DAMAGE TO THE EQUIP-
MENT.
THERMOSTAT LEADS
THERMOSTAT
WIRE ENTRANCE
HOLE
120 VAC
ELECTRICAL
SUPPLY
Figure 1
Wall Thermostat
The wall thermostat should be mounted approximately 5
feet from the floor. The preferred location is on an inside
wall situated in an area with good air circulation, and where
the temperature will be reasonably representative of other
living areas the thermostat is controlling.

ELECTRICAL WIRING

CONNECT ELECTRICAL POWER AND CON-
TROLS
All electrical wiring within the furnace has been made at the
factory.
All wiring connected to the furnace must comply with and
be electrically grounded in accordance with the National
Electric Code and any applicable local codes or regula-
tions, (ANSI-C1 / NFPA-70), Canadian Standard and all lo-
cal codes having jurisdiction.
A separate 120 V.A.C. supply circuit must be used for the
furnace. The circuit should be protected by a 15 amp fuse
or circuit breaker.
Run the 120 volt supply through the opening in the side of
the furnace. Join the electrical supply wires with suitable
connectors to the electrical supply leads in the junction
box. Replace the junction box cover.
An approved strain relief connector at the junction box must
be used. When using a three wire system, connect the me-
chanical ground to the green headed screw in the back of
the junction box. See figure 14 and following wiring dia-
grams.
CONTROL WIRING NOT SHOWN
SYSTEM SWITCH
JUNCTION BOX
(COVER REMOVED)
FAN
SWITCH
GROUND
SCREW
(GREEN HEAD)
4
1
A/C
COMBUSTION AIR
RELAY
BLOWER RELAY
DGAM & DGAT
SERIES
Avoid locations where the thermostat could be subject to
drafts from outside, or exposed to direct light from lamps,
sun, fireplaces, etc., or affected by air from a duct register
blowing directly on the thermostat.
16
NOTE
LIMIT
SWITCH
5
3
STRAIN
RELIEF