BLAUBERG Ventilatoren TE 1.5 Operation Manual

BLAUBERG Ventilatoren TE 1.5 Operation Manual

Timer / sensors with timer
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

TIMER / SENSOREN MIT TIMER
TE 1.5 / TI 1.5
HSE 1.5 / HSI 1.5
LSE 1.5 / LSI 1.5
IRSE 1.5 / IRSI 1.5
BETRIEBSANLEITUNG
T_HS_LS_IRS_v.2(3)_DE_EN_105x148.indd 1
22.09.2015 14:22:50

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TE 1.5 and is the answer not in the manual?

Questions and answers

Summary of Contents for BLAUBERG Ventilatoren TE 1.5

  • Page 1 TIMER / SENSOREN MIT TIMER TE 1.5 / TI 1.5 HSE 1.5 / HSI 1.5 LSE 1.5 / LSI 1.5 IRSE 1.5 / IRSI 1.5 BETRIEBSANLEITUNG T_HS_LS_IRS_v.2(3)_DE_EN_105x148.indd 1 22.09.2015 14:22:50...
  • Page 2: Table Of Contents

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de INHALT Einleitung Allgemeine Information Sicherheitsvorschriften Lager- und Beförderungsvorschriften Herstellergarantie Lieferumfang Technische Daten Aufbau Betriebsarten Montage Anschluss an das Stromnetz Diagnose und Abhilfe Abnahmebescheinigung Anschlussprotokoll Garantiekarte T_HS_LS_IRS_v.2(3)_DE_EN_105x148.indd 2 22.09.2015 14:22:50...
  • Page 3: Einleitung

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de Das Lagerumfeld darf keinen aggressiven und/ EINLEITUNG oder chemischen Dämpfen, Mischungen oder vorliegende Betriebsanleitung enthält Fremdstoffen ausgesetzt sein, Korrosion eine technische Beschreibung, technische verursachen Anschluss-Abdichtungen Daten, Funktions- Wartungsvorschriften,...
  • Page 4: Lieferumfang

    TECHNISCHE DATEN von 60% bis zu 90% überschreitet, legt der Feuchtigkeitssensor mit Timer die Spannung an den Tabelle 1. Technische Daten angeschlossenen Lüfter an. Wenn die Steuerspannung abgeschaltet wird oder TE 1.5 HSE 1.5 LSE 1.5 IRSE 1.5 Parameter TI 1.5 HSI 1.5...
  • Page 5: Montage

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de Aktiver Modus wird durch die Betätigung des 1. Die Betriebs-Kontrolllampe leuchtet grün bei den Bewegungssensors, das Schließen des externen Nennbetriebsbedingungen mit dem Laststrom bis Schalters, Reaktion des Feuchtigkeitssensors oder zu 1.5 A.
  • Page 6: Anschluss An Das Stromnetz

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de Abb. 2. TE / HSE/ LSE / IRSE Montage Abb. 3. TI / HSI / LSI / IRSI Montage ANSCHLUSS ANS STROMNETZ WARNUNG Trennen Sie das Gerät von der Stromversorgung vor jeglichen Arbeiten. Service- und Wartungsarbeiten sind nur vom Fachpersonal gestattet, das über eine gültige Zulassung für elektrische Arbeiten verfügt.
  • Page 7: Abnahmebescheinigung

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de ABNAHMEBESCHEINIGUNG Das Gerät TE 1.5 HSE 1.5 LSE 1.5 IRSE 1.5 TI 1.5 HSI 1.5 LSI 1.5 IRSI 1.5 ist als betriebsfähig anerkannt. Das Produkt entspricht den Europäischen Normen und Standarten, den Richtlinien über die...
  • Page 8 www.blaubergventilatoren.de T_HS_LS_IRS v.2(3) / DE T_HS_LS_IRS_v.2(3)_DE_EN_105x148.indd 8 22.09.2015 14:22:55...
  • Page 9 TIMER / SENSORS WITH TIMER TE 1.5 / TI 1.5 HSE 1.5 / HSI 1.5 LSE 1.5 / LSI 1.5 IRSE 1.5 / IRSI 1.5 OPERATION MANUAL T_HS_LS_IRS_v.2(3)_DE_EN_105x148.indd 9 22.09.2015 14:22:56...
  • Page 10 TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de CONTENT Introduction General Safety rules Storage and transportation rules Manufacturer's warranty Delivery set Technical data Design Operation modes Mounting Connection to power mains Troubleshooting and fault handling Acceptance certificate Connection certificate Warranty card...
  • Page 11: Introduction

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de The storage environment must not be subjected INTRODUCTION to any aggressive and/or chemical evaporations, The present operation manual contains technical admixtures, foreign objects that may provoke description, technical data sheets, operation and corrosion and damage connection tightness.
  • Page 12: Delivery Set

    When the control voltage is off or in case of the indoor Table 1. Technical data humidity drop below the set point, the humidity sensor with timer keeps sending power supply to the fan within TE 1.5 HSE 1.5 LSE 1.5 IRSE 1.5 Parameters TI 1.5...
  • Page 13: Mounting

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de The timer operation duration is individually service life of the timer/ sensor with timer. To avoid that, adjustable. The connected fan runs. The light indicator it is recommended to decrease the connected load blinks once in 1 second.
  • Page 14: Connection To Power Mains

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de Fig. 3. TI / HSI / LSI / IRSI mounting CONNECTION TO POWER MAINS WARNING Cut off power supply prior to any operations with the device. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations after careful study of the present user’s manual.
  • Page 15: Acceptance Certificate

    TE / TI / HSE / HSI / LSE / LSI/ IRSE / IRSI www.blaubergventilatoren.de ACCEPTANCE CERTIFICATE The product TE 1.5 HSE 1.5 LSE 1.5 IRSE 1.5 TI 1.5 HSI 1.5 LSI 1.5 IRSI 1.5 is recognizes as serviceable. The product complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility.
  • Page 16 www.blaubergventilatoren.de T_HS_LS_IRS v.2(3) / EN T_HS_LS_IRS_v.2(3)_DE_EN_105x148.indd 16 22.09.2015 14:22:57...

This manual is also suitable for:

Ti 1.5Hse 1.5Hsi 1.5Lse 1.5Lsi 1.5Irse 1.5 ... Show all