Trion HERRMIDIFIER Herrmidicool Installation, Operation & Maintenance Manual

In-duct air/water atomization system

Advertisement

Quick Links

Herrmidicool
READ & SAVE THESE INSTRUCTIONS
Installation, Operation & Maintenance
T R I O N
| w w w . t r i o n i a q . c o m
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HERRMIDIFIER Herrmidicool and is the answer not in the manual?

Questions and answers

Summary of Contents for Trion HERRMIDIFIER Herrmidicool

  • Page 1 Herrmidicool ™ READ & SAVE THESE INSTRUCTIONS Installation, Operation & Maintenance T R I O N | w w w . t r i o n i a q . c o m ®...
  • Page 2: Table Of Contents

    I n s t a l l a t i o n , O p e r a t i o n & M a i n t e n a n c e M a n u a l TABLE OF CONTENTS Warranty ...............................3 I.
  • Page 3: Warranty

    LEAKAGE OR SPILLAGE. defective part) other than TRION/HERRMIDIFIER factory labor. DANGER OF BURNS TRION/HERRMIDIFIER shall not be responsible for loss of use of any product, loss of time, inconvenience, or damage to other THE HUMIDIFIER CONTAINS HIGH TEMPERATURE equipment, or any other indirect or consequential damage with COMPONENTS AND DELIVERS STEAM AT 100°C/212°F.
  • Page 4: Introduction

    I n s t a l l a t i o n , O p e r a t i o n & M a i n t e n a n c e M a n u a l I.
  • Page 5: Controls

    I n s t a l l a t i o n , O p e r a t i o n & M a i n t e n a n c e M a n u a l before mist is distributed into the duct.
  • Page 6: Start-Up Checklist

    I n s t a l l a t i o n , O p e r a t i o n & M a i n t e n a n c e M a n u a l (0-5 VDC).
  • Page 7: Start-Up

    • Air & Water Lines – blow out once a year. Check joints for Call your local TRION/HERRMIDIFIER representative to leaks once a year. schedule a trouble-free start-up. Minimum two week notice •...
  • Page 8: Nozzle Troubleshooting

    Rebuilding kits are available b. One or more of the heads may have been improperly from your local TRION/HERRMIDIFIER representative. adjusted or the individual shut-off valve may be throttled. Perform a complete restart and readjustment of the No valves should ever be throttled.
  • Page 9: Nozzle Diagram

    I n s t a l l a t i o n , O p e r a t i o n & M a i n t e n a n c e M a n u a l XVI.
  • Page 10: Wiring Diagram

    I n s t a l l a t i o n , O p e r a t i o n & M a i n t e n a n c e M a n u a l WARNING XVI.
  • Page 11 I n s t a l l a t i o n , O p e r a t i o n & M a i n t e n a n c e M a n u a l THIS PAGE INTENTIONALLY LEFT BLANK.
  • Page 12 TRION ® 101 McNeill Rd. | Sanford, NC 27330 P: 800.884.0002 | F: 800.458.2379 | www.trioniaq.com | customerservice@trioniaq.com Form No. 269604-001 Rev. 06/18 © 2018 TRION. All Rights Reserved.