Ec Declaration Of Conformity - Prolyte PRO LYFT AETOS PAE-250DC Series Operating And Maintenance Manual

Table of Contents

Advertisement

1.
GENERAL INFORMATION
Attention: All users must read these operating
instructions carefully prior to the initial operation. These

EC DECLARATION OF CONFORMITY

instructions are intended to acquaint the user with the
hoist controller and enable him/her to use it to the full
ProLyft B.V.
extent of its intended capabilities.
Industriepark 9
The operating instructions contain important information
9351 PA Leek
on how to handle the hoist controller in a safe, correct and
The Netherlands
economic way. Acting in accordance with these
We, ProLyft B.V., hereby declare that the design, construction and commercialised execution of the below mentioned machine
instructions helps to avoid dangers, reduce repair costs
complies with the essential health and safety requirements of the EC Machinery Directive 2006/42/EC.
and downtime and to increase the reliability and lifetime of
the hoist controller.
The validity of this declaration will cease in case of any modification or supplement not being agreed with us previously.
Anyone involved in doing any of the following work with
Furthermore, validity of this declaration will cease in case the machine will not be operated correctly and in accordance with
the hoist controller must read the operating instructions
the operating instructions and/or not be inspected regularly.
and act accordingly:
Product:
• Operation, including preparation, trouble shooting and
Type:
cleaning
• Maintenance, inspection, repair
• Transport
Apart from the operating instructions and the accident
prevention act valid for the respective country and area
Capacity:
where the hoist controller is used, also the commonly
accepted regulations for safe and professional work must
Serial No.:
be adhered to.
The user is responsible for the proper and professional
The machinery fulfils the following additional EC directives:
instruction of the operating personnel.
Suitable for entertainment use
The following harmonised standards were used:
The PROLYFT AETOS hoist controllers are specially
designed for use in the Entertainment industry. They must
only control electric chain hoists that are suitable for use
in the Entertainment industry.
Combining the hoist controller with different type of
The following other technical standards and specifications were used: IGVW SQ P2:2018-10
electric chain hoists might lead to unwanted, unexpected
or dangerous situations.
The party authorised to compile the technical file:
The PROLYFT AETOS hoist controllers are not designed
to control hoists suspending or lifting loads above people.
Read the manual of the electric chain hoists before
starting to operate them with the hoist controller.
Date of signing:
Regulations
The accident prevention act and/or safety regulations of
the respective country for using manual and electric chain
hoists must be strictly adhered:
• Europe:
• Machine Directive 2006/42/EG
Signed by:
• Safety of Machinery NEN 12100:2010
• Germany: BGV D6, BGV D8
Additional regulations are in effect for lifting or suspending
loads over people.
Germany: SQ P2
The Netherlands: NPR8020-10
United
Kingdom: BS7950-1
Maintenance/Repair
In order to ensure correct operation, not only the
operating instructions, but also the conditions for
inspection and maintenance must be complied with. If
defects are found or abnormal noise is to be heard stop
using the hoist controller immediately.
Attention: Before starting t o work on electrical
components the power-supply is to be cut off.
2.
INCORRECT OPERATION
• Do not exceed the rated power capacity per controlled
channel.
• Do not lift stuck or jammed loads.
• Do not shortly and frequently actuate the up/down
switch.
• Do not control hoists if the movement of the load is not
visible from the operating position.
• Do not control hoists if you are skilled for lifting loads
• Do not use cables with damaged strain reliefs and/or
isolation.
Electric Chain Hoist AETOS series
• Do not use any input- or output cables that are not
PAE-1000DC-XXXX
suitable for the supplied voltage and / or current.
PAE-1000LV-XXXX
• Do not use the Thuja data connection (link in, link out)
PAE-500DC-XXXX
with other network devices unless these devices are
PAE-500LV-XXXX
specified to be suitable for use in the Thuja data
PAE-250DC-XXXX
PAE-250LV-XXXX
network.
• Do not connect the controller to a mains connection that
250 - 2000kg
is not properly fused.
• Do not use the controller without proper grounding.
Serial numbers for the individual units are recorded
• Do not connect more then one hoist on a single
channel.
Low Voltage Directive, 2006/95/EC
EMC Directive, 2004/108/EC
ELECTRIC CONNECTIONS
3.
RoHS Directive 2011/65/EU
All electric connections must be used with respect for the
WEEE Directive 2012/19/EU
specified voltages and maximum power consumption.
EN 818-7:2002+A1:2008
Power input:
EN 14492-2:2006+A1:2009
EN 60204-32:2008
The power input connector is a 5pin CEEform connector
EN ISO 12100:2010
suitable for 3 phase 32Amp / 400Volt. 3 Phases, neutral
and ground.
Depending on the type of controller it can be plugged in to
ProLyft B.V.,
either a 3 phase 400V or a 3 phase 230V mains
Industriepark 9
connections.
9351 PA Leek
The Netherlands
Make sure the mains connection is fused at maximum
32Amps per phase. It is advised to use circuit breakers
with a C or D characteristic.
07-12-2018
Make sure the mains connection is properly grounded.
Improper grousing might lead to dangerous with the risk
of electric shock.
Maximum power consumption per hoist.
Erik Koopmans
Manager Operations ProLyft B.V.
Each hoist channel is capable of switching an electric
chain hoist with maximum power consumption of 1,5kW.
Power output to the hoists
For each 4 hoist channels there is a Harting 16 output
connector.
Make sure the cables (and each individual wire of the
cable) connected to the output connector are suitable for
minimum 10Amps at 400V per wire.
To avoid voltage drops longer cables should have bigger
wire diameters.
page ! 4
27
AETOS Range
AETOS Range

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents