POTS IN a BOX ATA Appliance
INSTALLATION GUIDE
WHAT CAN YOUR
NEW DEVICE DO?
Virtually every application that requires a copper
wire-line can now be replaced with one device!
DataRemote 2020
DRI-9080
Revision No. 005 August 2020
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRI-9080 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DataRemote DRI-9080

  • Page 1 DRI-9080 POTS IN a BOX ATA Appliance INSTALLATION GUIDE WHAT CAN YOUR NEW DEVICE DO? Virtually every application that requires a copper wire-line can now be replaced with one device! Page 1 DataRemote 2020 Revision No. 005 August 2020...
  • Page 2 PSTN Modem Data The DataRemote DRI-9080 wireless router with VoIP is a stand-alone device which facilitates clear and reliable voice quality over the Internet. It is fully compatible with Session Initiation Protocol (SIP) industry standards and can integrate with many other SIP devices and software on the market.
  • Page 3: Table Of Contents

    ▪ Phase 2 - Installation Tasks – Locate existing POTS lines...............18 ▪ Phase 3 - Cut-over Fire Panel lines to new DRI-9080 device..............19 ▪ Phase 4 - Testing Fire Alarm Communication over DataRemote's DRI-9080 device......20 ▪...
  • Page 4: What Comes In The Box

    WHAT COMES IN THE BOX DATAREMOTE DRI-9080 DEVICE AC POWER ADAPTER SET OF MOUNTING ETHERNET AND PHONE (RJ-11) CABLES HARDWARE Page 4 DataRemote 2020 Revision No. 005 August 2020...
  • Page 5: What Do You Need To Know Before Installing Your Device

    WHAT DO YOU NEED TO KNOW BEFORE INSTALLING YOUR DEVICE Before you can connect your DataRemote DRI-9080 device to the Internet and use it, you must have access to high-speed Internet. A high-speed Internet connection can be accessed through DSL, cable modem, and/or a leased line.
  • Page 6: What Is On The Back Of Your Device

    Wide Area Network (Internet) connector outlet Connector for accessing the Internet. One (1) Ethernet outlets LAN1 Connector for local networked devices. Eight (8) RJ-11 FXS Ports PHONE1-8 Connector for voice, fax, modem or alarm Page 6 DataRemote 2020 Revision No. 005 August 2020...
  • Page 7: Basic Installation

    Connect the WAN port of your device to a modem, switch, router or Internet source with an Ethernet cable (RJ-45). DISCLAIMER: This is just a representation of a modem. Modem models and appearance may vary depending on your Internet provider. Page 7 DataRemote 2020 Revision No. 005 August 2020...
  • Page 8 Connect the LAN port on your device with an Ethernet cable (RJ-45) to your equipment or computer that needs to receive an Internet connection from the DataRemote DRI-9080 device. Your device allows you to connect one (1) device. STEP 4 Connect the RJ-11 (Phone line) from your phone or equipment requiring a phone line to one of the DataRemote DRI-9080 device’s FXS ports.
  • Page 9: Service Technician Installation

    If Fire Alarm Panel included in install, test that Fire Alarm Panels primary & secondary lines accordingly, by calling out through the DataRemote DRI-9080 device. If RJ-31 style jack is used, verify that tip/ring connections are on pins 4 & 5 of jack.
  • Page 10: Materials List Provided By Dataremote

    MATERIALS LIST PROVIDED BY DATAREMOTE Basic Package Contains (Refer to “What comes in the Box” section) ▪ One (1) DataRemote DRI-9080 device. ▪ One (1) 100-240VAC, 50/60Hz, 1.0A to 15.0VDC, 2.0A power adapter ▪ One (1) AC Power Adapter Cord.
  • Page 11: Prep-Installation Tasks

    DataRemote DRI-9080 device. a. Please report any store access issue to your Project Manager immediately 3. If the DataRemote DRI-9080 device was shipped to the site in advance of your dispatch; please obtain this package from the Manager.
  • Page 12: Phase 1 - Dataremote Dri-9080 Device Assembly/Pre-Test + Fire Panel Location

    ASSEMBLE THE DATAREMOTE DRI-9080 DEVICE TO PRE-TEST: 1. Remove the DRI-9080 device: 2. Insert power cord into power outlet (located on the rear right side of the DRI-9080 device). Plug the power cord into an AC power outlet. 3. Once the DataRemote DRI-9080 device is plugged int, install the device mounting screws in the selected location.
  • Page 13 4. If step 3 successful record the calling phone number in the Checklist for this site as Phone 1's (primary) new DRI-9080 number. Repeat steps 1 - 4 accordingly using the phone 2-8 line ports of the DataRemote DRI-9080 device (if the lines are voice lines.) TESTING FIRE PANEL.
  • Page 14 WARNING! DO NOT TOUCH THE EXISTING RJ-31 POTS JACKS NEAR FIRE PANEL UNLESS INSTRUCTED TO DO SO. Once the Fire Alarm Panel is located, you will need to connect the DataRemote DRI-9080 device’s 2 phone ports configured for Alarm respectively with the Fire Alarm Panel's primary & secondary phone line ports preferably utilizing the existing cabling already connecting those ports to their current POTS lines.
  • Page 15 FIRE-Primary & FIRE-Secondary SMT box respectively 5. Mark cables: • Mark the DataRemote DRI-9080 device’s alarm line 1 port's phone cord with a "1" or "P" to reflect its connection to the DataRemote DRI-9080 device's alarm line if it is inadvertently removed it is clear where to reconnect it.
  • Page 16 Testing Fire Alarm communication over DataRemote DRI-9080 device. (See following page) The DataRemote DRI-9080 device will be set in auto alarm mode, meaning it will detect what type of supported protocol the panel communicates in (Contact-ID, SIA, Pulse...Etc.) NOTE: DO NOT PLUG IN A BUTT SET TO THE DRI-9080 DEVICE AND MAKE A TEST CALL ON ANY OF THE ALARM LINES AS THIS WILL DEACTIVATE THE AUTO DETECT MODE.
  • Page 17 5. Call fire alarm vendor to confirm they show the error and that it has been cleared: • Have New DataRemote DRI-9080 device TN's recorded in your checklist handy to give to alarm vendor when calling, as well as store name and location number.
  • Page 18 PHASE 5 Testing Fax Lines. Fax Mode Details: ▪ Fax Works in VoIP and Fax modes on the DataRemote DRI-9080 device. ▪ FAX calls in VOIP mode cannot be assured of full transmission and or quality. ▪ Fax in Fax Mode works in basic (9600 Baud), Normal (14400 Baud) with ECM (Error Correction Mode) ON &...
  • Page 19: Post Installation Tasks

    Present installation Checklist to Customer pint of contact for signature. ▪ Call tech check-in/check-out line to be released from the site. ▪ Upload all taken & required pictures to your work order. Page 19 DataRemote 2020 Revision No. 005 August 2020...
  • Page 20: Deliverables

    13) Photo of Fire Panel's controller display before cut-over to the DataRemote DRI- 9080 device’s ports. 14) Photo of all cable management. 15) Wide angle photo of entire wall & the DataRemote DRI-9080 device closeup to show completed installation job. Picture/scan of both pages of Tech Checklist.
  • Page 21: Statements And Disclaimers

    911/E911 services in the U.S. for this Service. In compliance with the Federal Communications Commission (FCC) WC Docket No. 05-196, DataRemote, Inc. hereby advises all current and potential customers that enhanced E911/911 calling services are available at this time but may not be available in all service areas and may/or may...
  • Page 22: Statements And Disclaimers (Continued)

    Answering Point (PSAP), preventing or delaying emergency response. If Customer changes the phone number used for 911 calling, Customer must register the new E911 CLID number and its associated address with DataRemote, in order to enable 911 capabilities for the updated number. Failure to do so may result in 911 services not being...
  • Page 23: Certifications

    (Current Device for this Manual) DataRemote CDS-9070 Router DataRemote CDS-9090 Router Certified Devices Device Model Appliance Type Manufacture Company Brand Regulatory Status Date CDS-9010 Router DataRemote, Inc. DataRemote Incorporated Federally-Regulated 11/12/2019 Consumer Product Page 23 DataRemote 2020 Revision No. 005 August 2020...
  • Page 24: Certificate Of Compliance

    C E R T I F I CAT E O F C O M P L I ANCE 20190725 - MH63085 Certificate Number Report Reference MH63085-20190717 2019-JULY-25 Issue Date DATAREMOTE INC Issued to: 18001 Old Cutler Rd, Suite 600 Miami FL 33157 BATTERIES,HOUSEHOLD AND COMMERCIAL, This certificate confirms that representative samples of...
  • Page 25 CERTIFICATE OF COMPLIANCE 20190919 -E500070 Certificate Number Report Reference E500070-A3-UL 2019-SEPTEMBER-19 Issue Date DATAREMOTE INC Issued to: 18001 Old Cutler Rd, Suite 600 Miami FL 33157 INFORMATION TECHNOLOGY EQUIPMENT INCLUDING This certificate confirms that representative samples of ELECTRICAL BUSINESS EQUIPMENT...