3. Front Overlay and Keypad Display Weight Status Percentage Signs Status Note Stable, on for dynamic mode, off for static mode ~ Gross weight Net weight Unit Stop Stop Material 1-4 M1 ~ M4 >> Fast filling > Fine filling...
Keys’ functions for parameter set or choose Keys Menu Parameter set Parameter Input Return Return Cancel and Quit Previous Increase digits Down Next Move right Enter Quit confirm Quit confirm 4. Rear Back Interface PCE-N45F...
PCE-N45F-IO PCE-N45F-DA 5. Load Cell Interface It can be connected with 6x350Ω analog load cells (around 58Ω minimum resistance), to confirm the range of the load cells, the total resistance (TSR) can be calculated with the formula as below: Input resistance(Ω)...
6-wire load cell or junction box 4-wire load cell or junction box 6. Serial Interface It has only one serial interface, to change it by switch for RS232 or RS485,method as below: Pins RS-232 RS-485 后 盖 板 Rear Rear 后...
Page 9
I/O interface drawing Output – OM/O0/O1/O2/O3 Input – IM/I0/I1 PCE-N45F-IO has 4 passive input and 8 relay open output...
High level:10~24VDC Input 3 Low level:0~3VDC Input 4 IN_COM Input common port 8. Analog Quantity Output PCE-N45F supply many types of analog signals which with proportional output according to the weight of the scale Pins Signal Note VOUT Voltage output Output resistance 0~600Ω, output can be:...
9. Parameter Set 9.1 Enter setting menu On weighing mode,keep pressing key to enter parameter setting mode. 9.2 Quit Setting On any mode,continuous press key to return to previous step or quit the setting mode. 9.3 Main Set Menu Press key or key to select the menu to be set, press...
9.4.1 Scale Set Press key or key to select the menu to be set, press key to enter the chosen menu, press key to return to previous step. Max.capacity Range: 1~200000. Default:100. Press key to move the cursor, press to change the chosen digits, press to save to return to previous step.
Page 13
Press key to change the division, Press Enter to save and return, press key to return without change Zero Calibration Press key to return without change Press key to choose √ or X, If √ chosen, press key to enter zero calibration, or return directly.
Page 14
Put the weight on the scale Input the weight value the same as the calibration weight Press key to move the cursor. Press key to change the digits. Press key to save the change and start to calibrate. Press key to cancel and return. The indicator is sampling the A/D data of calibration point, it ends when it became 0% from 100%.
This parameter can be retrieved and can be modified, after tested well, please record those three parameters for use in future. When the data in EEPROM get problem, reload those three parameters, it doesn’t need to do calibration again. If the same model indicator to be changed and those three parameters reloaded, it doesn’t need to do calibration, either.
Page 16
Tare Operation Choices: Disable tare Enable tare Press key to change Press key to save and return. Press key to cancel and return. Zero upon Power on Choices: 0%, 2%, 20% Press key to change Press key to save and return. Press key to cancel and return.
Page 17
0:None 1:Vibration checking range = 1d; 2:Vibration checking range = 2d; 3:Vibration checking range = 3d; 4:Vibration checking range = 4d; 5:Vibration checking range = 5d; Press key to change Press key to save and return. Press key to cancel and return. Digital filtering Set range of 1-9, the more, the weight is more stable and the longer time to be stable.
9.4.3 Batching Set Press key to chose the menu to be set. Press key to enter. Press key to return previous step. Batching mode: Choices:4 materials batching Single material weight lose Free setpoint. Press key to change Press key to save and return. Press key to cancel and return.
Page 19
If there is no I/O board, it can be set to be 1 only. If there is the I/O board, it can be set from 1-4. Press key to change Press key to save and return. Press key to cancel and return. Feeding door 1:single door single speed 2:double doors double speed...
Page 20
Discharge mode Choice:Auto or manual Press key to change Press key to save change and return. Press key to cancel and return. Empty scale range Choice:0%~9.9%×F.S Only the weight on the scale is less than this range and the cursor and output is effective, otherwise it’s taken as not empty.
Page 21
Choice:0.0~9.9 seconds After batching start, after the delay time, it can start to tare, open the door and start to feed. Press key to move cursor. Press key to modify the chosen digits. Press key to save and return to previous step.
Page 22
the menu to be set, press to enter. Press key to return the previous step. Choice:0.0~9.9 seconds, the stabling time after batching finish of material 2 Choice:0.0~9.9 seconds, the stabling time after batching finish of material 3 Choice:0.0~9.9 seconds, the stabling time after batching finish of material 4 Delay time of discharge Choice:0.0~9.9 seconds.
Page 23
Choice:0~99 Checking tolerance after the times of batching, if it was set of 0, it will not check. Press key to change Press key to save change and return. Press key to cancel and return. Tolerance range set Choice:0%~9.9%×Target weight When it checking, if value of the actual weight minus the target weight is less than this value, it will be taken as ok, if not, it’s...
Choice:0%~9.9%×Target weight Only the value of actual weight minus target weight is less this range, it goes to adjust, when it’s set to be 0, this function off. Press key to move cursor. Press key to modify the chosen digits. Press key to save and return to previous step.
Page 25
Choice:300 bit/s; 600 bit/s; 1200 bit/s; 2400 bit/s; 4800 bit/s; 9600 bit/s; 19200 bit/s; 38400 bit/s; 57600 bit/s; 115200 bit/s; Press key to change Press key to save change and return. Press key to cancel and return. Parity check Choice: 8 digits no parity check 7 digits even parity check 7 digits odd parity check 8 digits even parity check...
Press key to cancel and return to previous step. 9.4.5 Analog quantity output Press key or key to choose the menu to be set, press key to enter. Press key to return the previous step. Output type choose Choice:0~+5V; 0~+10V; -5V~+5V;...
Full scale calibration (coarse-small-fine) Press key or key to choose the menu to be set, press key to enter. Press key to return the previous step. 9.4.6 Diagnosis and maintenance Press key or key to choose the menu to be set, press key to enter.
Page 28
Reload Choose √ to reload the default parameters Reloading… Free calibration Choose √ to enter Menus Press key or key to choose the menu to be set, press key to enter. Press key to return the previous step. Input the full capacity of load cells Press key to move cursor.
Page 29
Input the sensitivity of load cells Press key to change Press key to save change and return. Press key to cancel and return. Zero calibration Adjust the present weight manually Press key to move cursor. Press key to modify the chosen digits.
Page 30
Input test interface Output interface test Choose √ to enter test menu Output test interface Backup parameters Choose √ to backup parameters Input the password...
Page 31
Password wrong Backup Retrieve the backup parameters Choose √ to retrieve the backup parameters Indicates that there is no backup parameters Retrieving… Alternate output mapping Choices: Tolerance output, fast feeding output, fine feeding output, discharging output. If the original output interface broken or with problem, you can mapping that interface to this alternate one by changing the cables.
Press key to save change and return. Press key to cancel and return. 9.5 Recipes Parameters set Basic + 4 materials type Press key or key to choose the menu to be set, press key to enter. Press key to return the previous step. IO + 4 materials type Press key or...
Page 33
M1 recipe set Press key or key to choose the menu to be set, press key to enter. Press key to return the previous step. Target weight: The final weight filled in the tank/container, etc. Press key to move cursor. Press key to modify the chosen digits.
Page 34
Fine weight: The relative weight between TARGET and FAST (when it finish the fast filling and change to fine filling), it’s the relative value but not actual value. Press key to move cursor. Press key to modify the chosen digits. Press key to save and return to previous step.
Page 35
It needed to be set when it using for losing weight filling Lower limitation: the minimum remaining after the end of discharging. Upper limitation: the approximated maximum weight it can reach. During feeding, if the weight <(target + lower limitation), the indicator will open the supplement feeding valve until the weight reach to upper limitation and then start to discharge.
Preaction 1 set Press key to move cursor. Press key to modify the chosen digits. Press key to save and return to previous step. Press key to cancel and return to previous step. Preaction 2 and preaction 3 the same set as above 9.6 Printing table format Press key or...
Screensaver time set If it’s set to be 0, the function off Press key or key to choose the menu to be set, press key to enter. Press key to return the previous step. Screen contrast adjust, the bigger number, the more bright the screen.
Bit5 Always 1 Always 1 Bit6 Always 0 Always 0 Bit7 Always 0 Always 0 10.2 Command transmitting format A Command sign Note “C” or “c” Clear tare “P” or “p” Print gross tare net “T” or “t” Tare “Z” or “z” Zero 10.3 Continuous transmit format B 10.4 Command output format B...
SPAN E1+ ENTER NEWLINE Input data is too small: SPAN E2+ ENTER NEWLINE Input data is too big: SPAN E3+ ENTER NEWLINE Loading weight is too big: SPAN E4+ ENTER NEWLINE Indicator weight reading and status, the indicator response format: Tare weight reading and status, the indicator response: 10.5 MODBUS output format MODBUS is the master-slave type network communication protocol, this indicator acts as the...
Page 40
1=material 4 in fine feeding 01~11:current recipe numbers(1~3) 1=batching run 1=batching suspense 1=discharging 1=feeding finish, waiting for discharging 0000=0.001;0011=0.01;0110=0.1;1001=1; 40004 0001=0.002;0100=0.02;0111=0.2;1010=2; 0010=0.005;0101=0.05;1000=0.5;1011=5; 1100=10;1101=20;1110=50; current division. 1=batching tolerance 1=scale vibrate 1=manual feeding mode 1=manual discharging mode 1~4 material batching mode: actual batched weight of current material 1. 40005 Single material losing weight mode: the current batched value of this filling.
Page 41
40037 Preaction quantity of setpoint 2 40038 Preaction quantity of setpoint 3 40039 Quantity used of material 1 (higher digits) 40040 Quantity used of material 1 (lower digits) 40041 Quantity used of material 2 (higher digits) 40042 Quantity used of material 2 (lower digits) 40043 Quantity used of material 3 (higher digits) 40044...
10.6 Multi materials jointed work with relay connected The below chart is for connecting of 4 materials batching, the input and output can be connected as common source or common grounded, for single material, connect the three relay to the connecting terminals of fast feeding, fine feeding and discharging.