Satel SP-4006 Series Installation Manual

Satel SP-4006 Series Installation Manual

Optical-acoustic outdoor siren

Advertisement

OPTICAL-ACOUSTIC
OUTDOOR SIREN
®
SP-4006
sp4006_en_06/09
The SP-4006 optical-acoustic outdoor siren is designed for intruder alarm systems. It comes
in two versions: SP-4006 and SP-4006 BL, which differ by the color of optical signaling (red
in the SP-4006, blue in the SP-4006 BL). As the light source in the siren, two sets of LEDs
are used. The sound signal is generated by means of a piezoelectric transducer. Design of
the siren housing, as well as the inner cover made from galvanized metal sheet, ensure a
high degree of tamper protection (against opening and/or pull-off from the mounting surface).
Electronic circuit is made in SMD technology and impregnated against adverse effect of
weather conditions, thus ensuring a high reliability of the equipment. The outer housing of the
siren is made of PC LEXAN high-impact polycarbonate, so it features a very high mechanical
strength and guarantees esthetic look of the equipment even after many years of service.

1. Installation

Fig. 1. Housing of the SP-4006 outdoor siren.
Explanations for Figure 1:
1 - cover retaining screws.
2 - cable entry hole.
3 - tamper element of the housing (should be screwed to the mounting surface; do not
apply excessive force, so as not to break the narrowings).
4 - mounting holes.
The SP-4006 outdoor siren should be mounted on a flat surface, at a place which is as hard
to access as possible, so as to minimize the risk of tampering. The device must be attached
to the surface by means of screws and expansion plugs. In order to take off the cover,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP-4006 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Satel SP-4006 Series

  • Page 1 OPTICAL-ACOUSTIC OUTDOOR SIREN ® SP-4006 sp4006_en_06/09 The SP-4006 optical-acoustic outdoor siren is designed for intruder alarm systems. It comes in two versions: SP-4006 and SP-4006 BL, which differ by the color of optical signaling (red in the SP-4006, blue in the SP-4006 BL). As the light source in the siren, two sets of LEDs are used.
  • Page 2 SP-4006 SATEL remove the two locking screws and lift it by an angle of approx. 60°. Be particularly careful when dismounting and remounting the inner sheet metal cover. Note: Make sure there is a suitable distance (minimum 2.5 cm) between the upper edge of the siren housing and the ceiling or another element which restricts the mounting position from the above.
  • Page 3 SATEL SP-4006 The SP-4006 BL siren has the two indicator LEDs situated on the opposite ends of housing sides, which are blinking alternately 1 s / 1 s when supply voltage is available at the +12V input. This function cannot be disabled.
  • Page 4 SP-4006 SATEL INTEGRA 32 GND +12V SENS. TMP SP-4006 Fig. 3. Way of connecting the SP-4006 siren to the alarm control panel with a resistor in the siren tamper circuit. The OUT2 high-current output is programmed as the supply one. The OUT3 and OUT4 low-current outputs control the signaling (OUT3 will trigger the acoustic signaling, and OUT4 –...
  • Page 5 SATEL SP-4006 SELECTION OF ACOUSTIC SIGNAL TYPE Designation Two-tone signal, step of pins status: modulated – pins open Steplessly modulated – pins shorted signal Steplessly modulated signal Steplessly modulated signal LIMITATION OF ACOUSTIC ALARM DURATION TO: Approx. 1 minute Approx. 5 minutes Approx.
  • Page 6 Built-in battery protection ..................fuse T 3.15 A Sound pressure ...................... up to 120 dB Working temperature range ................... -35…+55 °C Housing dimensions ..................148x254x64 mm Weight ..........................1.14 kg Latest EC declaration of conformity and product approval certificates can be downloaded from our web site www.satel.pl...
  • Page 8 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl...

This manual is also suitable for:

Sp-4006Sp-4006 bl