Download Print this page

Solar Plus Ajax CombiProtect Quick Start Manual

Advertisement

Quick Links

Solar Plus Ajax
1. FEATURES
Wireless sensor Ajax CombiProtect is designated for human motion de-
tection and glassbreak detection. It functions as a part of Ajax security
system.
2. SPECIFICATIONS
SPECIFICATION
Sensor type
Uses
Movement detection distance
Movement and glassbreak sensitivity 3 levels adjustable (low, medium, high)
Movement detection angle
Installation height suggested
Pet ignoring option
Glassbreak detection distance
Detecting element
Tamper protection
Radio signal power
Radio-frequency range
Maximum distance between sensor
and central unit
Power supply
Power supply voltage
Battery life
Operation temperatures range
Operation humidity
Dimensions
3. COMPONENTS
CombiProtect sensor, battery CR123A, installation set, manual
4. GETTING STARTED
4.1 Before installing the sensor, it is required to register it with the
Ajax security system. In order to register the sensor, it is necessary to
switch the Ajax security system's receiver to «Add Device» mode (the
receiver's manual explains how to accomplish it) and to put the switch
«2» (PICTURE 4) on the sensor to the «ON» position. The sensor's light
must blink at the moment of switching on. The registration request is
transmitted at the moment the sensor is switched on only! In case the
registration was not successful, switch off the sensor, wait for 5 sec-
onds and switch it on again. If the sensor's light blinks constantly (each
second during one minute), it means that the sensor is not registered.
The light blinks in the same way if the sensor is deleted from the reg-
istration list. Non-registered sensor blinks also throughout 3 seconds
during each activation.
4.2 Having registered the sensor successfully, select an appropriate lo-
cation to install it.
ATTENTION!
Make sure that in the installation location sensor has a stable radio con-
tact with the receiver! A maximum distance of 2000 m (6562 ft) between
the sensor and the receiver is mentioned as a comparison with other
devices. This distance was found as a result of open area tests. Con-
nection quality and distance between the sensor and the receiver can
vary depending on installation location, walls, compartments, bridg-
ings, as well as the thickness and constructional material. Signal com-
ing through the obstacles, loses power. For example, distance range
between the sensor and receiver, divided with two reinforced concrete
bearing walls, constitutes approximately 30 m (98.4 ft). Please note that
moving the sensor even 10 cm (4 in), it is possible to improve the signal
reception considerably.
Before installation make sure to check the signal level test in the place
where you intend to install the sensor! It is possible to launch a signal
strength test on the receiver's side. Test launching is described in the
receiver's manual.
ATTENTION!
Signal level test and detection zone test for sensors take some time to
start. A certain period of time is necessary for the receiver to send a test
request to the sensor, and for the sensor to send a test response.
CombiProtect
CombiProtect
MEANING
wireless
indoors
up to 12 m (39.4 ft)
88.5° horizontal / 80° vertical
2.4 m (7.9 ft)
Weight up to 20 kg (44 lb), size up to 50
cm (19.7 in)
up to 9 m (29.5 ft)
pyrosensor (movement), electret micro-
phone (glassbreak)
available
20 mW
868 MHz (Europe); 915 MHz (USA)
2000 m (6562 ft) (open area)
CR123A battery
3V
Up to 7 years
from 0°С (+32°F) to +50°С (+122°F)
up to 80%
110х65x50 mm (4.33x2.55x1.96 in)
RECEIVER
SENSOR'S LIGHT EMITTING DIODE DESCRIPTION
lights almost permanently, with
3 indication bars
short breaks each 1.5 seconds
2 indication bars
blinks 5 times per second
1 indication bar
blinks twice per second
0 bars
short flashes each 1.5 seconds
The signal should be not lower that medium so that the sensor works
in a stable way!
5. INSTALLATION
5.1 The sensor must be installed in such a way that the intruder's as-
sumed entrance was perpendicular to the sensor's lens axis. Glass-
break detection area is also to be considered. The sensor's microphone
is not to be turned from the window further that to 90°. Make sure to
check if the sensor is functioning at the point where it is going to be
installed!
5.2 In order to install the sensor, move the plastic fastening clip Smart-
Bracket (PICTURE 1) alongside the frame and remove it.
5.3 Install the fastening clip SmartBracket on the wall with a help of the
expansion bolts and self-tapping screws included in the set (PICTURE
2). The height suggested for the sensor installation is 2.4 m (7.9 ft).
5.4 Put the sensor on the SmartBracket. Once the sensor is fixed on the
SmartBracket, its light must blink. It means that the tamper on the sen-
sor is shut. In case the sensor does not blink, the tamper status must be
checked at the receiver configuration software!
PICTURE 1.
CombiProtect sensor and its SmartBracket
PICTURE 2.
SmartBracket wall installation scheme
ATTENTION!
Be careful while SmartBracket installing. Overexertion while installing
can cause deformation and, as a result, impossibility to install the sen-
sor or to its unreliable fastening. Fix the SmartBracket with the set's
assembling units only! Other fixing system use, for example, self-tap-
ping screws of big diameter, can damage fastening clip. Together with
self-tapping screws, there is a double stick tape in the set. It can be used
for temporary sensor fixing only. It is recommended not to use the tape
for the permanent fixing, as the tape dries up over time and the sen-
sor may fall down which can interfere with its functions or even cause
a breakdown.
Solar Sikring
excellent signal
medium signal
low signal
no signal
SmartBracket is to be moved
down and removed

Advertisement

loading

Summary of Contents for Solar Plus Ajax CombiProtect

  • Page 1 Solar Sikring Solar Plus Ajax CombiProtect RECEIVER SENSOR'S LIGHT EMITTING DIODE DESCRIPTION CombiProtect lights almost permanently, with 3 indication bars excellent signal short breaks each 1.5 seconds 2 indication bars blinks 5 times per second medium signal 1 indication bar...
  • Page 2 Solar Sikring 5.5 The sensor is installed! cy sound by switching off the light for 0.2 seconds. When it happens, during 1.5 seconds throw a metal object (such as a spoon) to the solid 5.6 Make sure that furniture, curtains, house plants, vases, decoration or glass constructions do not cover the sensor’s field of view and do not...